Connectrix MDS: Linecard Fails to Boot Up with Error 'PORT-5-MODULE_BRINGUP_NOT_ALLOWED'
Summary: A linecard that is physically inserted into a Director slot that was previously populated fails to boot.
This article applies to
This article does not apply to
This article is not tied to any specific product.
Not all product versions are identified in this article.
Symptoms
A Line card failed to boot when inserted in an MDS Director slot which was previously populated.
When the new line card is the same model as the original line card, then the following syslog message is seen:
%PORT-5-MODULE_BRINGUP_NOT_ALLOWED: Not allowing module 8 to come up for reason: Speed group configuration is not supported. (0x4029018c)
If the new line card is a different model than the original line card, then the following syslog message is seen:
%PORT-5-MODULE_BRINGUP_NOT_ALLOWED: Not allowing module 10 to come up for reason: Speed change not allowed (0x4029007f)
In both scenarios, the following sequences of syslogs are recorded:
%VMM-2-VMM_SERVICE_ERR: VDC1: Service SAP Port manager (high) for slot 8 returned error 0x402901ac (Module insertion failed) in if_bind sequence %IM-3-IM_RESP_ERROR: Component MTS_SAP_VMM opcode:MTS_OPC_IM_IF_VDC_BIND in vdc:1 returned error:Module insertion failed %IM-3-IM_SEQ_ERROR: Error (Module insertion failed) while communicating with component MTS_SAP_VMM opcode:MTS_OPC_IM_IF_VDC_BIND (for:RID_MODULE: 8) %MODULE-2-LCM_MODULE_INSERT_FAILURE_NEG_RSP: Slot-8 has failed to boot up because of service "Im SAP" due to module insertion failure
The module finally goes into a failure state as shown in show module command:
Mod Ports Module-Type Model Status
--- ----- ----------------------------------- ------------------ ----------
1 34 1/10/40G IPS,2/4/8/10/16G FC Module DS-X9334-K9 failure
Mod Power-Status Reason
--- ------------ ---------------------------
1 failure Unknown. Issue show system reset mod ...
Cause
Cisco interoperability issue
Resolution
Workaround:
To prevent this issue, run the command purge module x running-config while the slot is empty.
If the issue has already occurred, then take a backup of the configuration and run the following commands which are disruptive.
write erase write erase boot reload
Known fixed release:
None
Affected Products
Connectrix MDS-9706, Connectrix MDS-9706-V2, Connectrix MDS-9710, Connectrix MDS-9710-V2, Connectrix MDS-9718, Connectrix MDS-Series HardwareArticle Properties
Article Number: 000219178
Article Type: Solution
Last Modified: 16 Apr 2025
Version: 3