NetWorker: v9.0 impossibile clonare i lavori VMware sul dispositivo CloudBoost
Summary: La clonazione dei saveset VMware vProxy in CloudBoost ha esito negativo. ID saveset non validi, nessun elemento lavoro, errore: pool con nodi non supportati; Causa: versione 9.1 del nodo. ...
This article applies to
This article does not apply to
This article is not tied to any specific product.
Not all product versions are identified in this article.
Symptoms
La clonazione dei saveset dei backup VMware (backup vProxy) in un dispositivo CloudBoost ha esito negativo.
mm/dd/yyyy hh:mm:ss meridiem Following savesets will be skipped please make sure saveset id is valid and target pool is valid <SSID> mm/dd/yyyy hh:mm:ss meridiem failed to get mmd reservation with err: There are no savesets to clone, mmd reservation is skipped. . mm/dd/yyyy hh:mm:ss meridiem Unable to update '<SSID(53>/' status. Error: Work item <SSID(53)>/ not found in running list. mm/dd/yyyy hh:mm:ss meridiem Unable to set work item status for all failed save sets mm/dd/yyyy hh:mm:ss meridiem No valid input savesets - check CLONE SKIPPED SAVESETS! mm/dd/yyyy hh:mm:ss meridiem No valid backend job mm/dd/yyyy hh:mm:ss meridiem [ORIGINAL REQUESTED SAVESETS] mm/dd/yyyy hh:mm:ss meridiem <SSID(53)>/; mm/dd/yyyy hh:mm:ss meridiem [CLONE SKIPPED SAVESETS] mm/dd/yyyy hh:mm:ss meridiem <SSID>, <SSID>/<CLONE_ID>; mm/dd/yyyy hh:mm:ss meridiem Action clone 'clone' with job id <JOB_ID_number> is exiting with status 'failed', exit code 1 mm/dd/yyyy hh:mm:ss meridiem NSRCLONE failed for one or more savesets.
La revisione del log del daemon al momento <mm/dd/yyyy hh:mm:ss meridiem> dell'errore trova il messaggio:
71193 mm/dd/yyyy hh:mm:ss meridiem 0 0 0 708478784 29038 0 <NetWorker_Server_name> nsrd NSR info Protection Policy Notice: Starting action '<Action_name>' for workflow '<Policy_name>/<Workflow_name>' 165718 mm/dd/yyyy hh:mm:ss meridiem 5 5 0 109037312 29038 0 <NetWorker_Server_name> nsrd NSR critical Unable to clone save set with ID '<SSID>': The '<Pool_name>' pool includes incompatible storage nodes: Ensure that you upgrade the following storage nodes to version 9.1 or later: <CloudBoost_Storage_Node_name>. 71193 mm/dd/yyyy hh:mm:ss meridiem 0 0 0 708478784 29038 0 <NetWorker_Server_name> nsrd NSR info Error Alert: Clone operation failed with error: 'NSRCLONE failed for one or more savesets. '. 38758 mm/dd/yyyy hh:mm:ss meridiem 0 0 0 708478784 29038 0 <NetWorker_Server_name> nsrd NSR info policy notice: action clone failed 38758 mm/dd/yyyy hh:mm:ss meridiem 0 0 0 708478784 29038 0 <NetWorker_Server_name> nsrd NSR info policy notice: workflow <Workflow_name> failed 89017 mm/dd/yyyy hh:mm:ss meridiem 1 5 0 708478784 29038 0 <NetWorker_Server_name> nsrd NSR notice Scheduled resource list: NSR Protection Policy <Policy_name> exited with return code 1.
Cause
Richiesta di miglioramento. Problema noto: NW-I-404: NetWorker: Clonazione dei saveset vProxy in un appliance CloudBoost.
Resolution
Il Product Management sta esaminando questa richiesta di miglioramento. La richiesta è ancora in corso. Contattare il centro di assistenza clienti per assistenza e citare il codice di questo articolo.
SOLUZIONE: Con una datazone NetWorker 9.0.1 o successiva, configurare uno storage node esterno. Vedere "NetWorker 9.1 CloudBoost 2.1 Integration Guide" nella sezione "NetWorker 9.1: Configuring a device by using an external storage node for CloudBoost".
SOLUZIONE: Con una datazone NetWorker 9.0.1 o successiva, configurare uno storage node esterno. Vedere "NetWorker 9.1 CloudBoost 2.1 Integration Guide" nella sezione "NetWorker 9.1: Configuring a device by using an external storage node for CloudBoost".
Affected Products
Cloud Backup & Protection, NetWorkerArticle Properties
Article Number: 000065416
Article Type: Solution
Last Modified: 04 Dec 2025
Version: 5
Find answers to your questions from other Dell users
Support Services
Check if your device is covered by Support Services.