Dell Unity:如何使用 CLI 扩展 Unity 池
Summary: 有哪些选项可以在用户界面 (UI) 之外扩展 Dell Unity 池?
This article applies to
This article does not apply to
This article is not tied to any specific product.
Not all product versions are identified in this article.
Instructions
问题:无法从 UI 扩展池。
1.检查池的状态并获取驱动器和 RAID 组信息:
uemcli /stor/config/pool -name <pool_name> show -detail
Example:
14:11:25 service@xyz spb:~/user> uemcli /stor/config/pool -name XYZ123 show -detail
1: ID = pool_3
Type = Dynamic
Name = March2025
Description =
Total space = 3815810007040 (3.4T)
Current allocation = 20392058880 (18.9G)
Preallocated = 11551760384 (10.7G)
Remaining space = 3783866187776 (3.4T)
Subscription = 1182995120128 (1.0T)
Flash percent = 39%
Subscription percent = 31%
Alert threshold = 70%
Drives = 6 x 600.0G SAS; 6 x 400.0G SAS Flash 3
Number of drives = 12
RAID level = 5
Stripe length = 5
Rebalancing = no
Rebalancing progress =
Health state = Degraded/Warning (10)
Health details = "This storage pool exceeds the critical capacity threshold. Thin-provisioned resources may suffer data loss or become unavailable when the pool reaches full capacity. Snapshots may become invalid and replication sessions may stop synchronizing for storage resources provisioned in this pool. To allocate more storage space, add more disks to your system. (https://10.120.162.226/help/webhelp/en_US/index.html?#unity_c_storage_pool_at_or_near_full_capacity.html)"
2.根据要求插入驱动器。检查 RAID 组并插入驱动器以根据需要扩展池。
3.使用以下命令检查驱动器是否联机:
fbecli.exe
pdo
这些命令显示驱动器的数量和联机驱动器的状态。将此输出与上述输出进行匹配,以确定
pdo 输出中的驱动器多于池。
4.使用以下命令检查包含未配置驱动器的磁盘组:
uemcli /stor/config/dg -traditional show
此命令显示包含未配置驱动器的磁盘组。
示例:
1: ID = dg_28
Drive type = SAS Flash 3
FAST Cache = no
Drive size = 1575700986880 (1.4T)
Vendor size = 1.6T
Rotational speed = 0 rpm
Number of drives = 43
Unconfigured drives = 7
Capacity = 67755142435840 (61.6T)
Recommended number of spares = 2
- 使用以下命令检查要在其中添加驱动器的配置文件:
uemcli /stor/config/profile -traditional -configurable show
此命令显示要在其中添加驱动器的配置文件,以便根据 RAID 组扩展池。此外,请检查属于此配置文件的磁盘组。
例:
例:
1: ID = tprofile_1
Type = Traditional
Description = SAS Flash RAID5 (4+1)
Drive type = SAS Flash
RAID level = 5
Maximum capacity = 7878504934400 (7.1T)
Stripe length = 5
Disk group = dg_28
Maximum drives to configure = 5
Maximum capacity to configure = 6302669729792 (5.7T)
- 运行 uemcli 命令以扩展池:
uemcli -d 10.0.0.0 -u admin -p 'MyPassword123!' /stor/config/pool -id pool_1 extend -diskGroup dg_28 -drivesNumber 5 -storProfile tprofile_1
在上面的示例中,磁盘组为
dg_28,配置文件为 tprofile_1,则要扩展的池的 ID 为 pool_1,并且根据 RAID 组,扩展池的驱动器数量为 5。
在命令给出输出后,输出为
"Operation completed successfully.",则使用步骤 1 再次检查驱动器数量和池状态。
例:
15:12:26 root@xyz spb:/cores/service/user> uemcli /stor/config/pool show -detail
Storage system address: 127.0.0.1
Storage system port: 443
HTTPS connection
1: ID = pool_1
Type = Traditional
Name = File and VMware Production Pool
Description = Default production pool
Total space = 55718073860096 (50.6T)
Current allocation = 47159708909568 (42.8T)
Preallocated = 97010941952 (90.3G)
Remaining space = 8461354008576 (7.6T)
Subscription = 66559913492480 (60.5T)
Subscription percent = 119%
Alert threshold = 70%
Drives = 41 x 1.6T SAS Flash 3
Number of drives = 41
RAID level = 5
Stripe length = Mixed
Rebalancing = yes
Rebalancing progress = 0%
Health state = OK_BUT (7)
Health details = "This storage pool has exceeded the capacity threshold you specified. To allocate more storage space, add additional disks to your system. (https://10.120.162.226/help/webhelp/en_US/index.html?#unity_c_storage_pool_at_or_near_full_capacity.html)"
Protection size used = 0
Non-base size used = 0
Auto-delete state = Idle
Auto-delete paused = no
Auto-delete pool full threshold enabled = yes
Auto-delete pool full high water mark = 95%
Auto-delete pool full low water mark = 85%
Auto-delete snapshot space used threshold enabled = no
Auto-delete snapshot space used high water mark = 25%
Auto-delete snapshot space used low water mark = 20%
Compression space saved = 2968627707904 (2.6T)
Compression Percent = 6%
Compression Ratio = 1.1:1
Data Reduction space saved = 2968627707904 (2.6T)
Data Reduction Percent = 6%
Data Reduction Ratio = 1.1:1
All flash pool = yes
Additional Information
有关池配置 Documentation/unity-family/unity-p-pool-config,请参阅戴尔支持网站上。
Affected Products
Dell EMC Unity Family |Dell EMC Unity All FlashProducts
Dell EMC Unity Family |Dell EMC Unity All Flash, Dell EMC Unity FamilyArticle Properties
Article Number: 000020429
Article Type: How To
Last Modified: 12 Nov 2025
Version: 6
Find answers to your questions from other Dell users
Support Services
Check if your device is covered by Support Services.