Ovladač CSI pro uzly PowerFlex, které uvízly v CrashLoopBackoff

Summary: Ovladač CSI (Container Storage Interface) pro moduly PowerFlex uvízl ve smyčce CrashLoopBackoff s chybou "could not find given NAS server by name"

This article applies to This article does not apply to This article is not tied to any specific product. Not all product versions are identified in this article.

Symptoms

Pody uzlů se zobrazily v CrashLoopBackOff:

vxflexos-node-xxxxx 1/2 CrashLoopBackOff 48 (4m44s ago) 3h47m

V protokolech registrátora se zobrazily následující chyby:

I0212 19:23:51.989914       1 main.go:108] "Received NotifyRegistrationStatus call" status="&RegistrationStatus{PluginRegistered:false,Error:RegisterPlugin error -- plugin registration failed with err: rpc error: code = Unknown desc = could not find given NAS server by name,}"
E0212 19:23:51.989935       1 main.go:110] "Registration process failed with error, restarting registration container" err="RegisterPlugin error -- plugin registration failed with err: rpc error: code = Unknown desc = could not find given NAS server by name"

Tajemství ukazovalo následující záznam:

  nasName: none

Cause

Tajný kód byl nesprávně předáván v nasName of none , který v poli neexistoval.

Resolution

Rozlišení

Uživatel změnil tajný klíč pomocí dokumentace tak, aby buď odebral nasName položku, nebo ji nastavil na "" jako v následujícím příkladu:

nasName: ""