PowerFlex 4.X no se puede actualizar el dispositivo debido a la falta de ID de componentes de software

Summary: Durante una actualización de código después de una o dos horas, la interfaz de usuario volverá al funcionamiento normal y no se realizará ninguna actualización.

This article applies to This article does not apply to This article is not tied to any specific product. Not all product versions are identified in this article.

Symptoms

Situación

La actualización falla con errores de I/O en los registros de asmManager y errores de DEPURACIÓN, en los que no se puede ubicar el software para los ID de componentes. Como se muestra en las siguientes capturas de pantalla:

2024-05-08 13:15:08,281 [https-jsse-nio-9080-exec-9] (LCMService.java:379) [DEBUG] ALCM status = UPGRADING
2024-05-08 13:15:13,660 [JobMgrQuartzScheduler_Worker-69] (LCMService.java:379) [DEBUG] ALCM status = UPGRADING
2024-05-08 13:15:13,660 [JobMgrQuartzScheduler_Worker-69] (JobManager.java:1208) [DEBUG] 1 jobs of [class com.dell.asm.asmcore.asmmanager.tasks.external.UpgradePFMP - Job-9d1a07b3-e0c8-4a86-a128-d5a8ff14ec89] currently still running
2024-05-08 13:15:23,668 [JobMgrQuartzScheduler_Worker-69] (AlcmApplianceServiceProxy.java:97) [ERROR] Unable to get the LCM status: I/O error on GET request for https://alcm.powerflex:9020/alcm/appliance/status [alcm.powerflex]: Connection refused (Connection refused); nested exception is java.net.ConnectException: Connection refused (Connection refused)
2024-05-08 13:15:23,669 [JobMgrQuartzScheduler_Worker-69] (JobManager.java:1205) [WARN] Job waiting was aborted by callback for Job-9d1a07b3-e0c8-4a86-a128-d5a8ff14ec89
2024-05-08 13:15:23,669 [JobMgrQuartzScheduler_Worker-69] (ExternalJob.java:46) [DEBUG] Finished executing the job UpgradePFMP.Job-9d1a07b3-e0c8-4a86-a128-d5a8ff14ec89
2024-05-08 13:15:23,719 [JobMgrQuartzScheduler_Worker-69] (QuartzListener.java:185) [DEBUG] --> Entering jobWasExecuted() listener: UpgradePFMP.Job-9d1a07b3-e0c8-4a86-a128-d5a8ff14ec89
2024-05-08 13:15:23,725 [JobMgrQuartzScheduler_Worker-69] (QuartzListener.java:263) [DEBUG] --> Entering triggerComplete() listener: trigger: UpgradePFMP.Trg-9282239b-7aa4-4f20-bd60-42b624ee484d, nextFireTime: null
2024-05-08 13:15:23,726 [JobMgrQuartzScheduler_Worker-69] (QuartzListener.java:390) [DEBUG] --> Entering triggerFinalized() listener: UpgradePFMP.Trg-9282239b-7aa4-4f20-bd60-42b624ee484d
2024-05-08 13:15:24,268 [https-jsse-nio-9080-exec-5] (AlcmApplianceServiceProxy.java:97) [ERROR] Unable to get the LCM status: I/O error on GET request for https://alcm.powerflex:9020/alcm/appliance/status [alcm.powerflex]: Connection refused (Connection refused); nested exception is java.net.ConnectException: Connection refused (Connection refused)
2024-05-08 13:16:30,054 [https-jsse-nio-9080-exec-10] (JobManager.java:1041) [DEBUG] --> Entering jobAdded() listener: UpgradePFMP.Job-55354489-71ff-46a4-8465-d5fd28130355
2024-05-08 13:16:30,082 [https-jsse-nio-9080-exe
2024-05-08 00:09:48,718 [JobMgrQuartzScheduler_Worker-58] (FirmwareUtil.java:1734) [DEBUG] Unable to find Software Component for ID=111550,OS = null in RCM Intelligent Catalog 45.373.01
2024-05-08 00:09:48,909 [JobMgrQuartzScheduler_Worker-58] (FirmwareUtil.java:1734) [DEBUG] Unable to find Software Component for ID=typelib-1_0-Pango-1_0,OS = SLES15.4 in RCM Intelligent Catalog 45.373.01
2024-05-08 00:09:48,948 [JobMgrQuartzScheduler_Worker-58] (FirmwareUtil.java:1734) [DEBUG] Unable to find Software Component for ID=python3-traceback2,OS = SLES15.4 in RCM Intelligent Catalog 45.373.01
2024-05-08 00:09:49,112 [JobMgrQuartzScheduler_Worker-58] (FirmwareUtil.java:1734) [DEBUG] Unable to find Software Component for ID=27763,OS = null in RCM Intelligent Catalog 45.373.01
2024-05-08 00:09:49,358 [JobMgrQuartzScheduler_Worker-58] (FirmwareUtil.java:1734) [DEBUG] Unable to find Software Component for ID=libfuse3-3,OS = SLES15.4 in RCM Intelligent Catalog 45.373.01
2024-05-08 00:09:49,654 [JobMgrQuartzScheduler_Worker-58] (FirmwareUtil.java:1734) [DEBUG] Unable to find Software Component for ID=python3-PySocks,OS = SLES15.4 in RCM Intelligent Catalog 45.373.01

La actualización del código de impacto nunca se inicia.

Cause

En raras ocasiones, el código descargado se dañará, pero aún podrá agregarse a la plataforma de administración de PowerFlex (PFMP) mediante la interfaz de usuario.  

 

Resolution

  • Vuelva a descargar los paquetes actuales de RCM/IC.
  • Validar las sumas de comprobación
  • Cargar
  • Reintente la actualización de PFxM

Versión afectada

PowerFlex Manager 4.x

Products

PowerFlex appliance R650, PowerFlex appliance R6525, PowerFlex appliance R660, PowerFlex appliance R6625, Powerflex appliance R750, PowerFlex appliance R760, PowerFlex appliance R7625, PowerFlex appliance R640, PowerFlex appliance R740XD , PowerFlex appliance R7525, PowerFlex appliance R840 ...
Article Properties
Article Number: 000244328
Article Type: Solution
Last Modified: 04 Nov 2024
Version:  1
Find answers to your questions from other Dell users
Support Services
Check if your device is covered by Support Services.