소프트웨어 구성 요소 ID가 누락되어 PowerFlex 4.X 어플라이언스를 업그레이드할 수 없음

Summary: 1시간 또는 2시간 후에 코드를 업그레이드하는 동안 UI는 정상 작동으로 돌아가고 업그레이드는 수행되지 않습니다.

This article applies to This article does not apply to This article is not tied to any specific product. Not all product versions are identified in this article.

Symptoms

시나리오

asmManager 로그의 I/O 오류 및 구성 요소 ID에 대한 소프트웨어를 찾을 수 없는 DEBUG 오류로 인해 업그레이드가 실패합니다. 다음 화면에서 볼 수 있듯이 :

2024-05-08 13:15:08,281 [https-jsse-nio-9080-exec-9] (LCMService.java:379) [DEBUG] ALCM status = UPGRADING
2024-05-08 13:15:13,660 [JobMgrQuartzScheduler_Worker-69] (LCMService.java:379) [DEBUG] ALCM status = UPGRADING
2024-05-08 13:15:13,660 [JobMgrQuartzScheduler_Worker-69] (JobManager.java:1208) [DEBUG] 1 jobs of [class com.dell.asm.asmcore.asmmanager.tasks.external.UpgradePFMP - Job-9d1a07b3-e0c8-4a86-a128-d5a8ff14ec89] currently still running
2024-05-08 13:15:23,668 [JobMgrQuartzScheduler_Worker-69] (AlcmApplianceServiceProxy.java:97) [ERROR] Unable to get the LCM status: I/O error on GET request for https://alcm.powerflex:9020/alcm/appliance/status [alcm.powerflex]: Connection refused (Connection refused); nested exception is java.net.ConnectException: Connection refused (Connection refused)
2024-05-08 13:15:23,669 [JobMgrQuartzScheduler_Worker-69] (JobManager.java:1205) [WARN] Job waiting was aborted by callback for Job-9d1a07b3-e0c8-4a86-a128-d5a8ff14ec89
2024-05-08 13:15:23,669 [JobMgrQuartzScheduler_Worker-69] (ExternalJob.java:46) [DEBUG] Finished executing the job UpgradePFMP.Job-9d1a07b3-e0c8-4a86-a128-d5a8ff14ec89
2024-05-08 13:15:23,719 [JobMgrQuartzScheduler_Worker-69] (QuartzListener.java:185) [DEBUG] --> Entering jobWasExecuted() listener: UpgradePFMP.Job-9d1a07b3-e0c8-4a86-a128-d5a8ff14ec89
2024-05-08 13:15:23,725 [JobMgrQuartzScheduler_Worker-69] (QuartzListener.java:263) [DEBUG] --> Entering triggerComplete() listener: trigger: UpgradePFMP.Trg-9282239b-7aa4-4f20-bd60-42b624ee484d, nextFireTime: null
2024-05-08 13:15:23,726 [JobMgrQuartzScheduler_Worker-69] (QuartzListener.java:390) [DEBUG] --> Entering triggerFinalized() listener: UpgradePFMP.Trg-9282239b-7aa4-4f20-bd60-42b624ee484d
2024-05-08 13:15:24,268 [https-jsse-nio-9080-exec-5] (AlcmApplianceServiceProxy.java:97) [ERROR] Unable to get the LCM status: I/O error on GET request for https://alcm.powerflex:9020/alcm/appliance/status [alcm.powerflex]: Connection refused (Connection refused); nested exception is java.net.ConnectException: Connection refused (Connection refused)
2024-05-08 13:16:30,054 [https-jsse-nio-9080-exec-10] (JobManager.java:1041) [DEBUG] --> Entering jobAdded() listener: UpgradePFMP.Job-55354489-71ff-46a4-8465-d5fd28130355
2024-05-08 13:16:30,082 [https-jsse-nio-9080-exe
2024-05-08 00:09:48,718 [JobMgrQuartzScheduler_Worker-58] (FirmwareUtil.java:1734) [DEBUG] Unable to find Software Component for ID=111550,OS = null in RCM Intelligent Catalog 45.373.01
2024-05-08 00:09:48,909 [JobMgrQuartzScheduler_Worker-58] (FirmwareUtil.java:1734) [DEBUG] Unable to find Software Component for ID=typelib-1_0-Pango-1_0,OS = SLES15.4 in RCM Intelligent Catalog 45.373.01
2024-05-08 00:09:48,948 [JobMgrQuartzScheduler_Worker-58] (FirmwareUtil.java:1734) [DEBUG] Unable to find Software Component for ID=python3-traceback2,OS = SLES15.4 in RCM Intelligent Catalog 45.373.01
2024-05-08 00:09:49,112 [JobMgrQuartzScheduler_Worker-58] (FirmwareUtil.java:1734) [DEBUG] Unable to find Software Component for ID=27763,OS = null in RCM Intelligent Catalog 45.373.01
2024-05-08 00:09:49,358 [JobMgrQuartzScheduler_Worker-58] (FirmwareUtil.java:1734) [DEBUG] Unable to find Software Component for ID=libfuse3-3,OS = SLES15.4 in RCM Intelligent Catalog 45.373.01
2024-05-08 00:09:49,654 [JobMgrQuartzScheduler_Worker-58] (FirmwareUtil.java:1734) [DEBUG] Unable to find Software Component for ID=python3-PySocks,OS = SLES15.4 in RCM Intelligent Catalog 45.373.01

영향 코드 업그레이드가 시작되지 않습니다.

Cause

드물지만 다운로드한 코드가 손상되지만 UI를 사용하여 PFMP(PowerFlex Management Platform)에 추가할 수 있습니다.  

 

Resolution

  • 현재 RCM/IC 패키지를 다시 다운로드합니다.
  • 체크섬 확인
  • 업로드
  • PFxM 업그레이드 재시도

영향을 받는 버전

PowerFlex Manager 4.x

Products

PowerFlex appliance R650, PowerFlex appliance R6525, PowerFlex appliance R660, PowerFlex appliance R6625, Powerflex appliance R750, PowerFlex appliance R760, PowerFlex appliance R7625, PowerFlex appliance R640, PowerFlex appliance R740XD , PowerFlex appliance R7525, PowerFlex appliance R840 ...
Article Properties
Article Number: 000244328
Article Type: Solution
Last Modified: 04 Nov 2024
Version:  1
Find answers to your questions from other Dell users
Support Services
Check if your device is covered by Support Services.