PowerFlex 4.X Não é possível fazer upgrade do equipamento devido a IDs de componentes de software ausentes

Summary: Durante um upgrade de código após uma ou duas horas, a interface do usuário retornará à operação normal e nenhum upgrade será realizado.

This article applies to This article does not apply to This article is not tied to any specific product. Not all product versions are identified in this article.

Symptoms

Situação

O upgrade falha com erros de E/S nos logs do asmManager e erros de depuração em que o software não pode ser localizado para IDs de componentes. Conforme visto nas capturas de tela a seguir:

2024-05-08 13:15:08,281 [https-jsse-nio-9080-exec-9] (LCMService.java:379) [DEBUG] ALCM status = UPGRADING
2024-05-08 13:15:13,660 [JobMgrQuartzScheduler_Worker-69] (LCMService.java:379) [DEBUG] ALCM status = UPGRADING
2024-05-08 13:15:13,660 [JobMgrQuartzScheduler_Worker-69] (JobManager.java:1208) [DEBUG] 1 jobs of [class com.dell.asm.asmcore.asmmanager.tasks.external.UpgradePFMP - Job-9d1a07b3-e0c8-4a86-a128-d5a8ff14ec89] currently still running
2024-05-08 13:15:23,668 [JobMgrQuartzScheduler_Worker-69] (AlcmApplianceServiceProxy.java:97) [ERROR] Unable to get the LCM status: I/O error on GET request for https://alcm.powerflex:9020/alcm/appliance/status [alcm.powerflex]: Connection refused (Connection refused); nested exception is java.net.ConnectException: Connection refused (Connection refused)
2024-05-08 13:15:23,669 [JobMgrQuartzScheduler_Worker-69] (JobManager.java:1205) [WARN] Job waiting was aborted by callback for Job-9d1a07b3-e0c8-4a86-a128-d5a8ff14ec89
2024-05-08 13:15:23,669 [JobMgrQuartzScheduler_Worker-69] (ExternalJob.java:46) [DEBUG] Finished executing the job UpgradePFMP.Job-9d1a07b3-e0c8-4a86-a128-d5a8ff14ec89
2024-05-08 13:15:23,719 [JobMgrQuartzScheduler_Worker-69] (QuartzListener.java:185) [DEBUG] --> Entering jobWasExecuted() listener: UpgradePFMP.Job-9d1a07b3-e0c8-4a86-a128-d5a8ff14ec89
2024-05-08 13:15:23,725 [JobMgrQuartzScheduler_Worker-69] (QuartzListener.java:263) [DEBUG] --> Entering triggerComplete() listener: trigger: UpgradePFMP.Trg-9282239b-7aa4-4f20-bd60-42b624ee484d, nextFireTime: null
2024-05-08 13:15:23,726 [JobMgrQuartzScheduler_Worker-69] (QuartzListener.java:390) [DEBUG] --> Entering triggerFinalized() listener: UpgradePFMP.Trg-9282239b-7aa4-4f20-bd60-42b624ee484d
2024-05-08 13:15:24,268 [https-jsse-nio-9080-exec-5] (AlcmApplianceServiceProxy.java:97) [ERROR] Unable to get the LCM status: I/O error on GET request for https://alcm.powerflex:9020/alcm/appliance/status [alcm.powerflex]: Connection refused (Connection refused); nested exception is java.net.ConnectException: Connection refused (Connection refused)
2024-05-08 13:16:30,054 [https-jsse-nio-9080-exec-10] (JobManager.java:1041) [DEBUG] --> Entering jobAdded() listener: UpgradePFMP.Job-55354489-71ff-46a4-8465-d5fd28130355
2024-05-08 13:16:30,082 [https-jsse-nio-9080-exe
2024-05-08 00:09:48,718 [JobMgrQuartzScheduler_Worker-58] (FirmwareUtil.java:1734) [DEBUG] Unable to find Software Component for ID=111550,OS = null in RCM Intelligent Catalog 45.373.01
2024-05-08 00:09:48,909 [JobMgrQuartzScheduler_Worker-58] (FirmwareUtil.java:1734) [DEBUG] Unable to find Software Component for ID=typelib-1_0-Pango-1_0,OS = SLES15.4 in RCM Intelligent Catalog 45.373.01
2024-05-08 00:09:48,948 [JobMgrQuartzScheduler_Worker-58] (FirmwareUtil.java:1734) [DEBUG] Unable to find Software Component for ID=python3-traceback2,OS = SLES15.4 in RCM Intelligent Catalog 45.373.01
2024-05-08 00:09:49,112 [JobMgrQuartzScheduler_Worker-58] (FirmwareUtil.java:1734) [DEBUG] Unable to find Software Component for ID=27763,OS = null in RCM Intelligent Catalog 45.373.01
2024-05-08 00:09:49,358 [JobMgrQuartzScheduler_Worker-58] (FirmwareUtil.java:1734) [DEBUG] Unable to find Software Component for ID=libfuse3-3,OS = SLES15.4 in RCM Intelligent Catalog 45.373.01
2024-05-08 00:09:49,654 [JobMgrQuartzScheduler_Worker-58] (FirmwareUtil.java:1734) [DEBUG] Unable to find Software Component for ID=python3-PySocks,OS = SLES15.4 in RCM Intelligent Catalog 45.373.01

O upgrade do código de impacto nunca é iniciado.

Cause

Em raras ocasiões, o código baixado será corrompido, mas ainda poderá ser adicionado à PowerFlex Management Platform (PFMP) usando a interface do usuário.  

 

Resolution

  • Faça download novamente dos pacotes RCM/IC atuais.
  • Valide as somas de verificação
  • Carregar
  • Repetir o upgrade do PFxM

Versão afetada

PowerFlex Manager 4.x

Products

PowerFlex appliance R650, PowerFlex appliance R6525, PowerFlex appliance R660, PowerFlex appliance R6625, Powerflex appliance R750, PowerFlex appliance R760, PowerFlex appliance R7625, PowerFlex appliance R640, PowerFlex appliance R740XD , PowerFlex appliance R7525, PowerFlex appliance R840 ...