PowerFlex 4.X Det går inte att uppgradera enheten på grund av saknade programvarukomponent-ID:n

Summary: Under en koduppgradering efter en timme eller 2 återgår användargränssnittet till normal drift och ingen uppgradering utförs.

This article applies to This article does not apply to This article is not tied to any specific product. Not all product versions are identified in this article.

Symptoms

Scenario

Uppgraderingen misslyckas med I/O-fel i asmManager-loggar och DEBUG-fel där programvaran inte kan hittas för komponent-ID:n. Som du kan se i följande skärmdumpar:

2024-05-08 13:15:08,281 [https-jsse-nio-9080-exec-9] (LCMService.java:379) [DEBUG] ALCM status = UPGRADING
2024-05-08 13:15:13,660 [JobMgrQuartzScheduler_Worker-69] (LCMService.java:379) [DEBUG] ALCM status = UPGRADING
2024-05-08 13:15:13,660 [JobMgrQuartzScheduler_Worker-69] (JobManager.java:1208) [DEBUG] 1 jobs of [class com.dell.asm.asmcore.asmmanager.tasks.external.UpgradePFMP - Job-9d1a07b3-e0c8-4a86-a128-d5a8ff14ec89] currently still running
2024-05-08 13:15:23,668 [JobMgrQuartzScheduler_Worker-69] (AlcmApplianceServiceProxy.java:97) [ERROR] Unable to get the LCM status: I/O error on GET request for https://alcm.powerflex:9020/alcm/appliance/status [alcm.powerflex]: Connection refused (Connection refused); nested exception is java.net.ConnectException: Connection refused (Connection refused)
2024-05-08 13:15:23,669 [JobMgrQuartzScheduler_Worker-69] (JobManager.java:1205) [WARN] Job waiting was aborted by callback for Job-9d1a07b3-e0c8-4a86-a128-d5a8ff14ec89
2024-05-08 13:15:23,669 [JobMgrQuartzScheduler_Worker-69] (ExternalJob.java:46) [DEBUG] Finished executing the job UpgradePFMP.Job-9d1a07b3-e0c8-4a86-a128-d5a8ff14ec89
2024-05-08 13:15:23,719 [JobMgrQuartzScheduler_Worker-69] (QuartzListener.java:185) [DEBUG] --> Entering jobWasExecuted() listener: UpgradePFMP.Job-9d1a07b3-e0c8-4a86-a128-d5a8ff14ec89
2024-05-08 13:15:23,725 [JobMgrQuartzScheduler_Worker-69] (QuartzListener.java:263) [DEBUG] --> Entering triggerComplete() listener: trigger: UpgradePFMP.Trg-9282239b-7aa4-4f20-bd60-42b624ee484d, nextFireTime: null
2024-05-08 13:15:23,726 [JobMgrQuartzScheduler_Worker-69] (QuartzListener.java:390) [DEBUG] --> Entering triggerFinalized() listener: UpgradePFMP.Trg-9282239b-7aa4-4f20-bd60-42b624ee484d
2024-05-08 13:15:24,268 [https-jsse-nio-9080-exec-5] (AlcmApplianceServiceProxy.java:97) [ERROR] Unable to get the LCM status: I/O error on GET request for https://alcm.powerflex:9020/alcm/appliance/status [alcm.powerflex]: Connection refused (Connection refused); nested exception is java.net.ConnectException: Connection refused (Connection refused)
2024-05-08 13:16:30,054 [https-jsse-nio-9080-exec-10] (JobManager.java:1041) [DEBUG] --> Entering jobAdded() listener: UpgradePFMP.Job-55354489-71ff-46a4-8465-d5fd28130355
2024-05-08 13:16:30,082 [https-jsse-nio-9080-exe
2024-05-08 00:09:48,718 [JobMgrQuartzScheduler_Worker-58] (FirmwareUtil.java:1734) [DEBUG] Unable to find Software Component for ID=111550,OS = null in RCM Intelligent Catalog 45.373.01
2024-05-08 00:09:48,909 [JobMgrQuartzScheduler_Worker-58] (FirmwareUtil.java:1734) [DEBUG] Unable to find Software Component for ID=typelib-1_0-Pango-1_0,OS = SLES15.4 in RCM Intelligent Catalog 45.373.01
2024-05-08 00:09:48,948 [JobMgrQuartzScheduler_Worker-58] (FirmwareUtil.java:1734) [DEBUG] Unable to find Software Component for ID=python3-traceback2,OS = SLES15.4 in RCM Intelligent Catalog 45.373.01
2024-05-08 00:09:49,112 [JobMgrQuartzScheduler_Worker-58] (FirmwareUtil.java:1734) [DEBUG] Unable to find Software Component for ID=27763,OS = null in RCM Intelligent Catalog 45.373.01
2024-05-08 00:09:49,358 [JobMgrQuartzScheduler_Worker-58] (FirmwareUtil.java:1734) [DEBUG] Unable to find Software Component for ID=libfuse3-3,OS = SLES15.4 in RCM Intelligent Catalog 45.373.01
2024-05-08 00:09:49,654 [JobMgrQuartzScheduler_Worker-58] (FirmwareUtil.java:1734) [DEBUG] Unable to find Software Component for ID=python3-PySocks,OS = SLES15.4 in RCM Intelligent Catalog 45.373.01

Impact Code-uppgraderingen startar aldrig.

Cause

I sällsynta fall kan den nedladdade koden skadas men kan ändå läggas till i PowerFlex Management Platform (PFMP) med hjälp av användargränssnittet.  

 

Resolution

  • Ladda ner de aktuella RCM/IC-paketen igen.
  • Validera kontrollsummorna
  • Ladda upp
  • Försök att uppgradera PFxM igen

Berörd version

PowerFlex Manager 4.x

Products

PowerFlex appliance R650, PowerFlex appliance R6525, PowerFlex appliance R660, PowerFlex appliance R6625, Powerflex appliance R750, PowerFlex appliance R760, PowerFlex appliance R7625, PowerFlex appliance R640, PowerFlex appliance R740XD , PowerFlex appliance R7525, PowerFlex appliance R840 ...
Article Properties
Article Number: 000244328
Article Type: Solution
Last Modified: 04 Nov 2024
Version:  1
Find answers to your questions from other Dell users
Support Services
Check if your device is covered by Support Services.