NMDA Informix dbspace -varmuuskopiointi epäonnistuu

Summary: NMDA Informix dbspace -varmuuskopiointi epäonnistuu

This article applies to This article does not apply to This article is not tied to any specific product. Not all product versions are identified in this article.

Symptoms

NMDA Informix dbspace -varmuuskopiointi epäonnistuu
Virhe bar_act.log

 Archive on rootdbs, datadbs, datadbs1, idx16kdbs1, datadbs3, calldbs1, idxdbs1, datadbs6, datadbs2, datadbs7, datadbs5, datadbs4, datadbs8, sbdbs1, tempdbs4, tempdbs, llogdbs, plogdbs1 ABORTED (Requested Level 0).
/home/informix/bin/onbar_d complete, returning 3 (0x03)
 XBSA Error: (BSAEndTxn) A system error occurred. Aborting XBSA session.

 Virhe libnsrifmx-lokista

nwbsa_close_saveset_session: received a network error (Severity 5 Number 22): Setting of retention lock for file '<filename>' failed 
ddp_set_retention_time() failed, su_name=, path_name=<path to file/filename >, Err: 5955-nfs setattr failed (nfs: Illegal minimum retention time)

Cause

NetWorker-laitteen ominaisuuksien säilytyslukitusasetus on Data Domainissa määritetyn säilytysajan ulkopuolella.

Resolution

Säädä Data Domainin säilytyksen lukitusasetuksia NetWorkerissa määritetyn säilytyksen lukitusjakson mukaan.
Tätä komentoa voi käyttää Data Domain -järjestelmässä.

  1. Avaa SSH-istunto Data Domainiin. Kirjaudu sisään sysadmin-käyttäjänä.
  2. Hae NetWorker-palvelimen mtree-polku:
# mtree list
  1. Säädä mtree min- ja max-säilytyksen lukitusjaksoja.
# mtree retention-lock set min-retention-period [period] mtree [mtree]
# mtree retention-lock set max-retention-period [period] mtree [mtree]