PowerFlex: OS-programrettelser kører ikke parallelt på PD'er
Summary: Når du forsøger at køre operativsystemopdatering (OS) på flere beskyttelsesdomæner (PD'er) parallelt, kører processen ikke samtidigt, selvom indstillingen parallel er valgt.
This article applies to
This article does not apply to
This article is not tied to any specific product.
Not all product versions are identified in this article.
Symptoms
Når du bruger REST API-kaldet liaRunOsPatching med parameteren isRunningInParallelOnPds, kører opdateringsprocessen ikke parallelt på noderne som forventet.
Eksemplerne nedenfor henviser til et PowerFlex Management Platform (PFMP) 4.x-system, men vil også forekomme på et PFMP 5.x-system.
Eksempel:
SDS_x.x.x.179 er den sidste i pd4, og SDS_x.x.x.178 er den første i pd3 - de behandles parallelt:
373 2023-05-28 02:41:25.747 MDM_CLI_CONF_COMMAND_RECEIVED INFO Command enter_maintenance_mode received, User: 'block-legacy-gateway'. [1080700]
374 2023-05-28 02:41:27.623 CLI_COMMAND_SUCCEEDED INFO Command enter_maintenance_mode succeeded. [1080700]
375 2023-05-28 02:41:27.624 MDM_CLI_CONF_COMMAND_RECEIVED INFO Command enter_maintenance_mode received, User: 'block-legacy-gateway'. [1080736]
376 2023-05-28 02:41:28.757 CLI_COMMAND_SUCCEEDED INFO Command enter_maintenance_mode succeeded. [1080736]
377 2023-05-28 02:43:09.208 MDM_CLI_CONF_COMMAND_RECEIVED INFO Command exit_maintenance_mode received, User: 'block-legacy-gateway'. [1082725]
378 2023-05-28 02:43:09.210 CLI_COMMAND_SUCCEEDED INFO Command exit_maintenance_mode succeeded. [1082725]
379 2023-05-28 02:43:10.296 MDM_CLI_CONF_COMMAND_RECEIVED INFO Command exit_maintenance_mode received, User: 'block-legacy-gateway'. [1082753]
380 2023-05-28 02:43:10.298 CLI_COMMAND_SUCCEEDED INFO Command exit_maintenance_mode succeeded. [1082753]
381 2023-05-28 02:45:11.438 SDS_MAINTENANCE_MODE_ENDED INFO SDS SDS_x.x.x.179 (ID: 222ade2a00000047) has exited maintenance mode
382 2023-05-28 02:45:13.237 SDS_MAINTENANCE_MODE_ENDED INFO SDS SDS_x.x.x.178 (ID: 222ade2900000046) has exited maintenance mode
Andre SDS'er behandles en efter en:
338 2023-05-28 02:19:11.790 MDM_CLI_CONF_COMMAND_RECEIVED INFO Command enter_maintenance_mode received, User: 'block-legacy-gateway'. [1053671]
339 2023-05-28 02:19:13.103 CLI_COMMAND_SUCCEEDED INFO Command enter_maintenance_mode succeeded. [1053671]
340 2023-05-28 02:20:55.097 MDM_CLI_CONF_COMMAND_RECEIVED INFO Command exit_maintenance_mode received, User: 'block-legacy-gateway'. [1055673]
341 2023-05-28 02:20:55.098 CLI_COMMAND_SUCCEEDED INFO Command exit_maintenance_mode succeeded. [1055673]
342 2023-05-28 02:22:01.075 SDS_MAINTENANCE_MODE_ENDED INFO SDS SDS_x.x.x.171 (ID: 222ade220000003f) has exited maintenance mode
343 2023-05-28 02:22:17.134 MDM_CLI_CONF_COMMAND_RECEIVED INFO Command enter_maintenance_mode received, User: 'block-legacy-gateway'. [1057416]
344 2023-05-28 02:22:18.974 CLI_COMMAND_SUCCEEDED INFO Command enter_maintenance_mode succeeded. [1057416]
345 2023-05-28 02:24:00.467 MDM_CLI_CONF_COMMAND_RECEIVED INFO Command exit_maintenance_mode received, User: 'block-legacy-gateway'. [1059439]
346 2023-05-28 02:24:00.471 CLI_COMMAND_SUCCEEDED INFO Command exit_maintenance_mode succeeded. [1059439]
347 2023-05-28 02:25:07.937 SDS_MAINTENANCE_MODE_ENDED INFO SDS SDS_x.x.x.172 (ID: 222ade2300000040) has exited maintenance mode
348 2023-05-28 02:25:24.567 MDM_CLI_CONF_COMMAND_RECEIVED INFO Command enter_maintenance_mode received, User: 'block-legacy-gateway'. [1061227]
349 2023-05-28 02:25:26.723 CLI_COMMAND_SUCCEEDED INFO Command enter_maintenance_mode succeeded. [1061227]
350 2023-05-28 02:27:08.792 MDM_CLI_CONF_COMMAND_RECEIVED INFO Command exit_maintenance_mode received, User: 'block-legacy-gateway'. [1063255]
351 2023-05-28 02:27:08.794 CLI_COMMAND_SUCCEEDED INFO Command exit_maintenance_mode succeeded. [1063255]
352 2023-05-28 02:28:19.283 SDS_MAINTENANCE_MODE_ENDED INFO SDS SDS_x.x.x.173 (ID: 222ade2400000041) has exited maintenance mode
Påvirkning
Opdatering af operativsystem tager længere tid at gennemføre end forventet.
Cause
På grund af et softwareproblem i OS-opdateringslogikken kører processen, der er beregnet til at køre kommandoer på noder i en PD parallelt, sekventielt i stedet.
Resolution
Der er ingen tilgængelig løsning.
Påvirkede versioner
PFMP 4.x
PFMP 5.x