Symptoms

PowerStore-verktøyet genererer hyppige varsler for;

(0x0030E202) Bus 5 enclosure 0 controller side B speed health was changed from PORT_RATE_TOO_LOW to PORT_RATE_NORMAL.

ELLER

0x0030de02 Bus 5 enclosure 1 controller side B speed health was changed from PORT_RATE_TOO_LOW to PORT_RATE_NORMAL

 

Skjermbilde av hastighetsvarsler for PowerStore-kabinett 0x0030e202 og 0x0030e203

Varslene for porthastighetsproblemet er forbigående, og automatisk gjenoppretting uten inngrep.

Ingen andre problemer identifiseres med apparatet.

svc_health_check Kjører rent, og ingen feil rapporteres.

Cause

Disse porthastighetsvarslene er et resultat av et avstemningsproblem. En forespørsel sendt til NVMe-utvidelseskapene for informasjon ble ikke mottatt i tide som resulterte i varselet.

Resolution

Løsning:
Det finnes ingen løsning tilgjengelig for å redusere disse varslene. De er godartede varsler og kan trygt ignoreres.

Fiksere:
Dette problemet er løst i PowerStoreOS versjon 3.6.1.0 og nyere.