PowerStore:0x0030e202或0x0030de02的頻繁警示
Summary: PowerStore 裝置會頻繁產生「0x0030e202」或「0x0030de02」的警示 擴充機櫃控制器連接埠 1 速度狀態已變更。
This article applies to
This article does not apply to
This article is not tied to any specific product.
Not all product versions are identified in this article.
Symptoms
PowerStore 應用裝置會頻繁針對下列項目產生警示:
(0x0030E202) Bus 5 enclosure 0 controller side B speed health was changed from PORT_RATE_TOO_LOW to PORT_RATE_NORMAL.
或
0x0030de02 Bus 5 enclosure 1 controller side B speed health was changed from PORT_RATE_TOO_LOW to PORT_RATE_NORMAL

埠速度問題的警報是暫時性的,無需任何干預即可自動恢復。
應用裝置未發現其他問題。svc_health_check 清理執行,且未報告任何錯誤。
Cause
這些連接埠速度警示是輪詢問題所導致。未及時收到傳送至 NVMe 擴充機櫃的資訊查詢,導致發出警示。
Resolution
因應措施:
沒有其他因應措施可減少這些警示。它們是良性警報,可以安全地忽略。
定:
此問題已在 PowerStoreOS 3.6.1.0 及更新版本中解決。
Affected Products
PowerStoreArticle Properties
Article Number: 000219037
Article Type: Solution
Last Modified: 29 Jul 2025
Version: 9