PowerScale : Échec isi_quota_notify_d processus

Summary: Les événements indiquant que le processus isi_quota_notify_d a échoué sont consignés dans le cluster.

This article applies to This article does not apply to This article is not tied to any specific product. Not all product versions are identified in this article.

Symptoms

Les événements montrent que l' isi_quota_notify_d Le processus a échoué est consigné sur le cluster. 


Event:  (Process isi_quota_notify_d failed)
 

AMST11-CL02-1# isi event events view 3347

          ID: 3347
     Started: 09/06 17:20
Causes Long: Process isi_quota_notify_d failed
         Lnn: 15
       Devid: 15
  Last Event: 2017-09-06T17:20:14
      Ignore: No
Ignore Time: Never
    Resolved: No
Resolve Time: Never
       Ended: --
      Events: 1
    Severity: warning




Messages de log :

2017-09-06T17:58:43+02:00 <3.6> AMSTxx-CL02-2 isi_quota_notify_d[30374]: Daemon initialized. 2017-09-06T17:58:43+02:00 <3.5> AMSTxx-CL02-2 isi_quota_notify_d[30374]: 
   Daemon obtained master lock 2017-09-06T17:58:43+02:00 <3.6> AMSTxx-CL02-2 isi_quota_notify_d[30374]: flxapi initialized. 2017-09-06T17:58:43+02:00 <3.3> AMSTxx-CL02-2 
   isi_quota_notify_d[30374]: Node is not having external IP. Releasing master lock. 2017-09-06T17:58:43+02:00 <3.5> AMSTxx-CL02-2 isi_quota_notify_d[30374]: Exiting.

Cause

Le nœud exécutant l’opération isi_quota_notify_d Le service n’a pas d’adresse IP externe.

Resolution

Pour conserver l’attribut isi_quota_notify_d en cas d’échec, chaque nœud d’Isilon doit disposer d’une adresse IP externe.

Affected Products

Isilon NL410

Products

Isilon NL410
Article Properties
Article Number: 000164453
Article Type: Solution
Last Modified: 11 Dec 2025