PowerScale : Échec isi_quota_notify_d processus
Summary: Les événements indiquant que le processus isi_quota_notify_d a échoué sont consignés dans le cluster.
This article applies to
This article does not apply to
This article is not tied to any specific product.
Not all product versions are identified in this article.
Symptoms
Les événements montrent que l' isi_quota_notify_d Le processus a échoué est consigné sur le cluster. Event: (Process isi_quota_notify_d failed)
AMST11-CL02-1# isi event events view 3347 ID: 3347 Started: 09/06 17:20 Causes Long: Process isi_quota_notify_d failed Lnn: 15 Devid: 15 Last Event: 2017-09-06T17:20:14 Ignore: No Ignore Time: Never Resolved: No Resolve Time: Never Ended: -- Events: 1 Severity: warning
Messages de log :
2017-09-06T17:58:43+02:00 <3.6> AMSTxx-CL02-2 isi_quota_notify_d[30374]: Daemon initialized. 2017-09-06T17:58:43+02:00 <3.5> AMSTxx-CL02-2 isi_quota_notify_d[30374]: Daemon obtained master lock 2017-09-06T17:58:43+02:00 <3.6> AMSTxx-CL02-2 isi_quota_notify_d[30374]: flxapi initialized. 2017-09-06T17:58:43+02:00 <3.3> AMSTxx-CL02-2 isi_quota_notify_d[30374]: Node is not having external IP. Releasing master lock. 2017-09-06T17:58:43+02:00 <3.5> AMSTxx-CL02-2 isi_quota_notify_d[30374]: Exiting.
Cause
Le nœud exécutant l’opération isi_quota_notify_d Le service n’a pas d’adresse IP externe.
Resolution
Pour conserver l’attribut isi_quota_notify_d en cas d’échec, chaque nœud d’Isilon doit disposer d’une adresse IP externe.
Affected Products
Isilon NL410Products
Isilon NL410Article Properties
Article Number: 000164453
Article Type: Solution
Last Modified: 11 Dec 2025
Version: 5
Find answers to your questions from other Dell users
Support Services
Check if your device is covered by Support Services.