PowerScale: Processen isi_quota_notify_d misslyckades
Summary: Händelser som visar att isi_quota_notify_d processen har misslyckats loggas i klustret.
This article applies to
This article does not apply to
This article is not tied to any specific product.
Not all product versions are identified in this article.
Symptoms
Händelser visar att isi_quota_notify_d Processen har misslyckats loggas i klustret. Event: (Process isi_quota_notify_d failed)
AMST11-CL02-1# isi event events view 3347 ID: 3347 Started: 09/06 17:20 Causes Long: Process isi_quota_notify_d failed Lnn: 15 Devid: 15 Last Event: 2017-09-06T17:20:14 Ignore: No Ignore Time: Never Resolved: No Resolve Time: Never Ended: -- Events: 1 Severity: warning
Loggmeddelanden:
2017-09-06T17:58:43+02:00 <3.6> AMSTxx-CL02-2 isi_quota_notify_d[30374]: Daemon initialized. 2017-09-06T17:58:43+02:00 <3.5> AMSTxx-CL02-2 isi_quota_notify_d[30374]: Daemon obtained master lock 2017-09-06T17:58:43+02:00 <3.6> AMSTxx-CL02-2 isi_quota_notify_d[30374]: flxapi initialized. 2017-09-06T17:58:43+02:00 <3.3> AMSTxx-CL02-2 isi_quota_notify_d[30374]: Node is not having external IP. Releasing master lock. 2017-09-06T17:58:43+02:00 <3.5> AMSTxx-CL02-2 isi_quota_notify_d[30374]: Exiting.
Cause
Noden som kör isi_quota_notify_d Tjänsten har ingen extern IP-adress.
Resolution
För att behålla isi_quota_notify_d tjänsten från att misslyckas måste varje nod i Isilon ha en extern IP-adress.
Affected Products
Isilon NL410Products
Isilon NL410Article Properties
Article Number: 000164453
Article Type: Solution
Last Modified: 11 Dec 2025
Version: 5
Find answers to your questions from other Dell users
Support Services
Check if your device is covered by Support Services.