PowerScale: SyncIQ ei replikoi käyttöaikaa (atime) kohdeklusteriin

Summary: Kun tietoja replikoidaan SyncIQ:n avulla, jos tiedostojen käyttöaika (atime) on muuttunut tuotantoklusterissa. Käyttöaikaa (atime) ei replikoida kohdeklusteriin, kun SyncIQ suorittaa replikoinnin loppuun. ...

This article applies to This article does not apply to This article is not tied to any specific product. Not all product versions are identified in this article.

Symptoms

Example:
 

Source:
SIQ1-1# stat -x /ifs/data/Sync_Test1
  File: "/ifs/data/Sync_Test1"
  Size: 8347045    FileType: Regular File
  Mode: (0777/-rwxrwxrwx)         Uid: (1001450/(1001450))  Gid: (1000069/(1000069))
Device: 136,1757282482   Inode: 4314169351    Links: 3
Access: Wed Jun 14 13:56:49 2023    <-- Access Time is newer than Target Access Time
Modify: Sun Jun 11 09:08:41 2023
Change: Sun Jun 11 09:08:41 2023


Target:
SIQ-2# stat -x /ifs/data/Sync_Test1
  File: "/ifs/data/Sync_Test1"
  Size: 8347045      FileType: Regular File
  Mode: (0777/-rwxrwxrwx)         Uid: (1000759/(1000759))  Gid: (1000195/(1000195))
Device: 18446744073709551597,18446744072263041268   Inode: 51447964289    Links: 3
Access: Sun Jun 11 09:08:35 2023   <-- Target Access time is not updated
Modify: Sun Jun 11 09:08:41 2023
Change: Sun Jun 11 10:21:48 2023

Cause

SyncIQ perustaa kaiken muutosten siirron tilannevedoksessa näkyviin attribuutteihin. SyncIQ voi siirtyä vain kerran lähteestä kohteeseen. Kun lähdetiedostoon on tehty jokin muu muutos, joka laukaisee COW:n, esimerkiksi käyttöoikeuksien muutos.

Resolution

Tämä on tarkoituksellista. Tulevaa koodia varten on lähetetty ominaisuuksien parannuspyyntö.
Article Properties
Article Number: 000215411
Article Type: Solution
Last Modified: 02 Jan 2026
Version:  2
Find answers to your questions from other Dell users
Support Services
Check if your device is covered by Support Services.