PowerProtect: Kan een vCenter Discovery-taak niet detecteren, fout: 500

Summary: PowerProtect Data Manager OS kan geen vCenter detecteren. Discovery-taakfout: 500 geen geldig certificeringspad naar het aangevraagde doel kunnen vinden.

This article applies to This article does not apply to This article is not tied to any specific product. Not all product versions are identified in this article.

Symptoms

Discovery Job Error: 500 : "{"code":500,"reason":"Failed to connect to <PPDM FQDN>: HTTP transport error: javax.net.ssl.SSLHandshakeException: 
PKIX path building failed: sun.security.provider.certpath.SunCertPathBuilderException: Unable to find valid certification path to requested target","remediation":null,"timestamp":1723825208953,"path":"/api/v2/vmwareservice/vcenters/validate-connection","extendedInfo":null}".

Cause

Certificaat verlopen

Resolution

  1. Maak verbinding met het PowerProtect Data Manager Management IP met behulp van SSH.
    1. Beleven /var/log/brs/vmdm
    2. Controleer in de logboeken: vmdm-discovery.log <unable to find valid certification path to requested target>
  2. Maak via een webbrowser verbinding met het PowerProtect Data Manager Management IP-adres.
    1. Ga naar >Administration Certificates, controleer in het rechterpaneel of er Certificaten verlopen zijn.
    2. Selecteer het verlopen certificaat en klik vervolgens op Certificaten opnieuw genereren
  3. Ga naar Infrastructure >Asset Sources, selecteer de vCenter-naam en klik op Discovery
  4. Ga naar Taken Systeemtaken>, controleer het proces van Handmatige detectie

Affected Products

Data Protection Suite, PowerProtect Data Protection Appliance, PowerProtect Data Manager Appliance
Article Properties
Article Number: 000227955
Article Type: Solution
Last Modified: 16 Oct 2024
Version:  1
Find answers to your questions from other Dell users
Support Services
Check if your device is covered by Support Services.