4.1.0.4
  • Initial release notes for PowerStoreOS 4.1.0.4 (January 2026)
4.1.0.3
  • Initial release notes for PowerStoreOS 4.1.0.3 (October 2025)
4.1.0.2
  • Changed PSSL09F-241 to PSSLDF-15242, changed PSSL09E-313 to PSSLDF-4055, and added PSSLDF-20249 (September 2025)
  • Initial release notes for PowerStoreOS 4.1.0.2 (September 2025)
4.1.0.1
  • Changed PSSL03E-227 to PSSLDF-327 (September 2025)
  • Initial release notes for PowerStoreOS 4.1.0.1 (July 2025)
4.1.0.0
  • Added MDT-433757 to Resolved issues (March 2025)
  • Updated the functional area and description for MDT-649452 (March 2025)
  • Initial release notes for PowerStoreOS 4.1.0.0 (February 2025)

PowerStoreOS 4.1.0.4 (Build: 2633110)

Resolved issues

Issue ID Description
PSSLDF-34194 In rare cases, if a NAS replication session fails over to the destination side and the source side comes back online, the NAS server on the source side may report a Production Mode of true instead of false.
PSSLDF-25330 System Manager (SYM) may become unresponsive and restart while handling SYM agent messages.
PSSLDF-23124 A PowerStore 3200Q or 5200Q storage system may experience a Data Unavailable (DU) event while the secondary M.2 drive is replaced or repaired.
PSSLDF-20041 When the load on a PowerStore system is very high, the scripts responsible with bringing up NAS services on a node may encounter an internal timing issue that causes the NAS container to restart multiple times.
PSSLDF-8516 If a PowerStore cluster was deployed using PowerStoreOS 2.x or earlier, Data Path (DP) trace collection may be disabled on the cluster after it is upgraded to PowerStoreOS 4.0 or later. 
PSSLDF-7018 In rare cases, performing a non-disruptive upgrade (NDU) may fail if gates are closed during metro reservation synchronization because SCSI-3 Persistent Reserve Release (PRR) operations are blocked.
PSSLDF-5336 Performing a non-disruptive upgrade (NDU) from PowerStoreOS 3.6.1.3 to 4.0.1.3 may fail due to a node becoming unresponsive and failing to reboot.
PSSLDF-4571 Hardware fencing may be mistakenly disabled after performing a non-disruptive upgrade (NDU) from PowerStoreOS 2.1.x to PowerStoreOS 3.5 or 3.6.
PSSLDF-4389 In rare cases, the Data Path (DP) on a destination PowerStore system may become unresponsive and restart when asynchronous replication, synchronous replication, metro replication, or migration is performed.
PSSLDF-3286 In rare cases, performing a non-disruptive upgrade (NDU) may fail due to an issue with the worker locking mechanism that allows two workers to run simultaneously.
PSSLDF-2852 When an NVRAM drive with the part number 005033035 or 005053655 is replaced, the PowerStore cluster may raise the false alert The drive does not meet FIPS requirements, even though the drive is online and functioning normally.
PSSLDF-2442 Event sequence numbers for the Data Path (DP) and Control Path (CP) may become misaligned, which can result in missed DP events and cause the CP to restart unexpectedly.
PSSLDF-2087 If a PowerStore 500T appliance incorrectly determines that a node reboot was caused by a power failure, the node may fail to stop in service mode and enter a reboot loop.
PSSLDF-1883 A PowerStore cluster may raise the alert DATA_PATH_SCHEDULE_MAPPER_RECOVERY_LATER (0x00200f02) after a node reboot or system outage occurs.
PSSLDF-1436 Error handling in logical merge processing may fail when a metadata inconsistency occurs in the logical copy count.
PSSLDF-1428 If the automatic download of software upgrades is enabled on a PowerStore system, a malformed manifest file can cause multiple software packages to be downloaded, leading to an out-of-space issue on the root partition.
PSSLDF-478 Information about metro volumes may be missing from Data Collection files because the Data Collect utility fails to collect metro volume data.
PSSLDF-255 A false metadata corruption message may appear in PowerStore system logs due to incorrect error handling during an internal metadata update process.
PSSL14K-485 If newly supported drives are present in a system running PowerStoreOS 4.0 or earlier, performing a non-disruptive upgrade (NDU) may fail and result in a Data Unavailable (DU) event.
PSSL14I-192 One or more Ethernet interfaces may become unavailable on a node after performing a non-disruptive upgrade (NDU).
PSSL08C-569 When a new drive is added to an appliance, manufacturing metadata on the drive may be lost. If both appliance nodes are rebooted after the metadata is lost, a Data Unavailable (DU) condition may occur.
PSSL03L-545 NVRAM resiliency mode may be unnecessarily triggered when a non-disruptive upgrade (NDU) fails.
PSSL01B-513 PowerStore systems only support increasing the size of vVols. However, in rare cases, a rollback scenario may attempt to decrease the size of a vVol, which can cause the Data Path (DP) to become unresponsive and restart.

Upgrade Package

If automatic download is not enabled on your PowerStore cluster, download the PowerStore upgrade package from the Dell Technologies Support site.

The name of the upgrade package on the support site is PowerStore T OS Upgrade LTS2025-4.1.0.4-2633110, and the file name of the downloadable upgrade package is PowerStoreT-LTS2025-4.1.0.4-2633110-retail.tgz.bin.

PowerStoreOS 4.1.0.3 (Build: 2596462)

Resolved issues

Issue ID Description
PSSLDF-20147 Upgrading the firmware on Intel SSDs may fail because of a timing issue during firmware activation, resulting in a Data Unavailable (DU) event. 
PSSLDF-3640 A metro outage may occur after performing a non-disruptive upgrade (NDU) from PowerStoreOS 3.6 or earlier to PowerStoreOS 4.0 or later on the first appliance of a cluster because SCSI reservation synchronization between the metro appliances may be blocked.

Upgrade Package

If automatic download is not enabled on your PowerStore cluster, download the PowerStore upgrade package from the Dell Technologies Support site.

The name of the upgrade package on the support site is PowerStore T OS Upgrade LTS2025-4.1.0.3-2596462, and the file name of the downloadable upgrade package is PowerStoreT-LTS2025-4.1.0.3-2596462-retail.tgz.bin.

PowerStoreOS 4.1.0.2 (Build: 2567482)

Resolved issues

Issue ID Description
PSSLDF-20249 Adjusted the Crypto-J library configuration to improve system stability and maintain consistent performance.
PSSLDF-15242 If a PowerStore appliance is deployed using PowerStoreOS 2.x or earlier, performing a nondisruptive upgrade (NDU) to PowerStoreOS 4.1 may cause the first node of the appliance to enter service mode. 
PSSLDF-4055 On a PowerStore 500T appliance, performing a non-disruptive upgrade (NDU) to PowerStoreOS 4.1 may cause the fru_use_state of the 4-port card to be incorrectly set to fru_not_in_use. 

Upgrade Package

If automatic download is not enabled on your PowerStore cluster, download the PowerStore upgrade package from the Dell Technologies Support site.

The name of the upgrade package on the support site is PowerStore T OS Upgrade LTS2025-4.1.0.2-2567482, and the file name of the downloadable upgrade package is PowerStoreT-LTS2025-4.1.0.2-2567482-retail.tgz.bin.

PowerStoreOS 4.1.0.1 (Build: 2529516)

Resolved issues

Issue ID Functional area Description
MDT-692523 Install or Upgrade A non-disruptive upgrade (NDU) to PowerStoreOS 4.1 may fail during post-upgrade operations due to a missing NDU-related code change in PowerStoreOS 4.1.
PSSLDF-327 Storage - Block Running an XCOPY command with invalid metadata may cause the Data Path (DP) service to become unresponsive and restart during a cache flush operation. This condition may cause the nodes of the appliance to reboot and result in a Data Unavailable (DU) condition.
MDT-707329 Storage - Block If an initiator object is deleted and a new initiator object with the same name is created, the deleted object may be restored after the System Manager (SYM) restarts. This condition can result in an "initiator name not unique" error and cause SYM to restart repeatedly until a Data Unavailable (DU) condition occurs.
MDT-700713 Storage - Block If a drive fails after both appliance nodes reboot, a Data Unavailable (DU) condition may occur, and the appliance may fail to recover automatically.
MDT-699337 Storage - Block A metadata page inconsistency may lead to an internal I/O timeout on a volume with snapshots enabled. This condition can cause appliance nodes to become unresponsive and reboot.
MDT-696700 Storage - Block If a TCP replication session repeatedly reconnects, the Data Path (DP) service may become unresponsive and restart.
MDT-694064 Storage - Block If a volume in a metro session experiences a high rate of unmap requests, I/O requests may exceed the token pool capacity, causing I/O to queue. If the I/O is queued for too long, the Data Path (DP) service may become unresponsive and restart.
MDT-689736 Storage - Block An internal timing issue in PowerStoreOS may cause a node to unexpectedly reboot.
MDT-617719 Storage - Block When a node is removed and reinserted into an appliance, the NVRAM drives may experience an issue that can lead to a faulted NVRAM pair and result in a Data Unavailable (DU) condition.
MDT-705861 Storage - File A Unified appliance may become unresponsive and reboot due to a segmentation fault caused by invalid memory access.
MDT-691358 Support Connectivity On a PowerStore cluster running PowerStoreOS 4.0 or later, enabling Support Connectivity using a Secure Connect Gateway connection may fail due to a failed health check. 

Upgrade Package

If automatic download is not enabled on your PowerStore cluster, download the PowerStore upgrade package from the Dell Technologies Support site.

The name of the upgrade package on the support site is PowerStore T OS Upgrade LTS2025-4.1.0.1-2529516, and the file name of the downloadable upgrade package is PowerStoreT-LTS2025-4.1.0.1-2529516-retail.tgz.bin.

PowerStoreOS 4.1.0.0 (Build: 2435323)

See the Dell PowerStoreOS 4.1.0.0 Release Notes on the PowerStore Info Hub

Affected Products

PowerStore 1000T, PowerStore 1200T, PowerStore 3000T, PowerStore 3200T, PowerStore 5000T, PowerStore 500T, PowerStore 5200T, PowerStore 7000T, PowerStore 9000T, PowerStore 9200T
Article Properties
Article Number: 000347814
Article Type: How To
Last Modified: 06 Jan 2026
Version:  6
Find answers to your questions from other Dell users
Support Services
Check if your device is covered by Support Services.