Symptoms
在重新映像过程中显示错误消息“Cannot find disk provider”(找不到磁盘提供程序)。
Cannot find disk provider
Traceback (most recent call last):
File "/root/bin/flashdisk_reimage.py", line 2375, in
sys.exit(main(getargs()))
File "/root/bin/flashdisk_reimage.py", line 2251, in main
setup_psi(args)
File "/root/bin/flashdisk_reimage.py", line 1703, in setup_psi
setup_psi_backup_device(args)
File "/root/bin/flashdisk_reimage.py", line 1763, in setup_psi_backup_device
psi_backup_device.providers.init_short()
File "/root/bin/flashdisk_reimage.py", line 1213, in init_short
bootdisk.init_providers(wipe=False)
File "/b/mnt/obj/b/mnt/src/amd64.amd64/isilon/lib/python/stage-3.8/usr/local/lib/python3.8/site-packages/isi/sys/bootdisk.py", line 729, in init_providers
File "/b/mnt/obj/b/mnt/src/amd64.amd64/isilon/lib/python/stage-3.8/usr/local/lib/python3.8/site-packages/isi/sys/bootdisk.py", line 730, in
IndexError: list index out of range
确认问题的命令是: isi_bootstrap_devices -b,这将生成以下输出:
isi-bsd# /usr/bin/isi_hwtools/isi_bootstrap_devices -b name: isi-bsd#
Cause
导致此问题的原因是节点的 A 底座的最高插槽编号中缺少磁盘。
Resolution
要解决该问题,请按照下列步骤作:
- 将驱动器放入节点 A 底座的最高插槽编号中。如果驱动器因故障而被卸下,请更换出现故障的驱动器,然后再继续。
- 如果您的驱动器位于最高 A 插槽编号中,请将该驱动器与底座中的另一个驱动器交换。重新拔插底座后,再次尝试重新映像过程。
注意: 如果您不确定或担心是否进行这些更改,请联系戴尔支持或浏览他们的网站以获得进一步的帮助。
提醒:请小心安装硬件,以免造成任何损坏。