Symptoms

OEMの事前チェックが失敗しています。エラー:
Oem Package Update
Perform Oem Extension update.

BeforeOEMUpdate
Tasks before OEMUpdate.

Test Firmware PreUpdate
Determine if OEM Firmware should be updated on physical nodes.

Firmware Check Health.
Check firmware health before update.

OEM.png

[Download Summary]をクリックします

Error.json: 
Type ‘FirmwareCheckHealth’ of Role ‘OEM’ raised an exception:\n\nError running Test-OEMFirmwareHealth: iDRAC: 10.224.190.3 has Critical Major faults, could not proceed with Firmware update….

OEMerror.png
 

Cause

4台のサーバーのうち3台でメモリー エラーが発生しました。続行する前に、これらを解決する必要があります。 
The memory health monitor feature has detected a degradation in the DIMM installed in DIMM_A6. Reboot system to initiate self-heal process.

Resolution

この問題を解決するには、メモリー エラーを修正します。

  1. 障害が発生したメモリーを示すiDRACでノードの待機電力を放電します。 
  2. ドレインしたら、PEP PowerShell ウィンドウで次のコマンドを実行します。 
get-virtualdisk -cimsession "s-cluster"
get-virtualdisk -cimsession "s-cluster" | get-storagejob
  1. すべてのストレージ ジョブが完了したら、iDRACからサーバーをコールド ブートします
  2. DIMMが修復されたことを確認します。
    The self-heal operation successfully completed at DIMM DIMM_A6.
  3. Azure Stackウィンドウで、ノードを開始します。
  4. Azure Stackウィンドウで、ノードを再開します。

Affected Products

Integrated System for Microsoft Azure Stack Hub, Integrated System for Microsoft Azure Stack Hub 14G
Article Properties
Article Number: 000200301
Article Type: Solution
Last Modified: 08 Sep 2025
Version:  3
Find answers to your questions from other Dell users
Support Services
Check if your device is covered by Support Services.