MFE ConGroup: ConGroup abend S0C4-11 occurred in PDADMIN during stop processing
Summary: The ConGroup abend S0C4-11 occurred in PDADMIN during stop processing.
This article applies to
This article does not apply to
This article is not tied to any specific product.
Not all product versions are identified in this article.
Symptoms
The ConGroup (Consistency Group) abend S0C4-11 occurred in module PDADMIN during stop processing. After that, the user had to use the CANCEL command to stop the ConGroup task.
Similar to the below symptoms:
P EMCCGRP CGRP282I STOP RECEIVED FROM CONSOLE CGRP282I STOP COMMAND RECEIVED CGRP675I SHUTDOWN DELAYED FOR 4 SECONDS ::::::::::::::::::::::::::::::::::::::::::::::: IEA045I AN SVC DUMP HAS STARTED AT TIME=22.35.06 DATE=04/02/2023 FOR ASID (0093) ERROR ID = SEQ49740 CPU00 ASID0093 TIME22.35.06.7 QUIESCE = NO IEA794I SVC DUMP HAS CAPTURED: 716 DUMPID=001 REQUESTED BY JOB (EMCCGRP ) DUMP TITLE=EMC ABEND S0C4 PGM:PDADMIN EP:161282F0 OFFSET:00002CE8 *** ABEND S0C4 DETECTED *** RTN: TRACE_FORWARDED_MESSAGE - CALLED FROM: CMPF: 84 CMPC: 0C4000 REAS: 00000011 PSW: 078C30009612AFD8 DATA AT PSW: 51484700 07009101 2005A7E4 PGM: PDADMIN EP: 161282F0 OFFSET: 00002CE8 R 0- 3: 00000000 7F198008 166E40C8 00000014 R 4- 7: 7F160968 7F198008 161282F0 00000054 R 8-11: 7F346810 7F346810 163B7060 16138F68 R12-15: 1612AF98 16838820 16832B08 168336D8 *** PERCOLATING WITH DUMP *** ::::::::::::::::::::::::::::::::::::::::::::::::::::::::::::::::::: C EMCCGRP IEA989I SLIP TRAP ID=X222 MATCHED. JOBNAME=EMCCGRP , ASID=0093. CGRP999I CSC LISTENER UNREGISTERED IEE301I EMCCGRP CANCEL COMMAND ACCEPTED IEF450I EMCCGRP EMCCGRP - ABEND=S222 U0000 REASON=00000000 TIME=22.46.24
Cause
This is due to a software issue.
AbendS0C4 in PDADMIN follows lengthy thrashing between PDADMIN and CGNODE during shutdown processing.
On a busy system where heartbeats are missed and subsequent Cross-system Communication (CSC) recovery pings are common, shutdown processing can result in control rapidly passing between PDADMIN and CGNODE. Then the normal shutdown could not stop the ConGroup task. The abend eventually occurred due to inaccessible storage.
Resolution
Permanent Fix:
- For Mainframe Enablers 8.5, Program Temporary Fix (PTF) SC85021 has been developed to correct the issue. It is available to download from Dell Technologies Online Support.
- For Mainframe Enablers 10.0.0, PTF SCA0012 has been developed to correct the issue. It is available to download from Dell Technologies Online Suppor.t
Additional Information
PTF Cover Notes:
++PTF(SCA0012) REWORK(2023290) . ++VER(Z038) FMID(SCGPA00) PRE( SCA0005 ) /* *------------------------------------------------------------- * PROBLEM DESCRIPTION(S): * ------------------------------------------------------------ * PROBLEM FIXED: MFE-16442 * USERS AFFECTED: All * PROBLEM DESCRIPTION: AbendS0C4 in PDADIN * DESCRIPTION DETAIL: * * AbendS0C4 in PDADIN follows lengthy thrashing between * PDADMIN and CGNODE during shutdown processing. * * PROBLEM RESOLUTION: * * On a busy system where heartbeats are missed and subsequent * CSC recovery pings are common, shutdown processing can * result in control rapidly passing between PDADMIN and * CGNODE with shutdown never being achieved. The abend * eventually occurred due to inaccessible storage. * * MODULES: PDADMIN * CGNODE * * ------------------------------------------------------------ * SCA0012 17 Oct 2023 19:28:42 * ------------------------------------------------------------ * OPT Summary * The following OPT was addressed by this PTF: * * MFE-16442 * *------------------------------------------------------------- ++PTF(SC85021) REWORK(2023114) . ++VER(Z038) FMID(SCGP850) PRE( SC85020 SC85023 ) /* *------------------------------------------------------------- * PROBLEM DESCRIPTION(S): * ------------------------------------------------------------ * PROBLEM FIXED: MFE-16419 * USERS AFFECTED: All * PROBLEM DESCRIPTION: AbendS0C4 in PDADIN * DESCRIPTION DETAIL: * * AbendS0C4 in PDADIN follows lengthy thrashing between * PDADMIN and CGNODE during shutdown processing. * * PROBLEM RESOLUTION: * * On a busy system where heartbeats are missed and subsequent * CSC recovery pings are common, shutdown processing can * result in control rapidly passing between PDADMIN and * CGNODE with shutdown never being achieved. The abend * eventually occurred due to inaccessible storage. * * MODULES: PDADMIN * CGNODE * ECGMONT * * ------------------------------------------------------------ * SC85021 24 Apr 2023 18:12:36 * ------------------------------------------------------------ * OPT Summary * The following OPT was addressed by this PTF: * * MFE-16419 *
Affected Products
Mainframe EnablersArticle Properties