ECS: resourcesvc hopper på grund af overdrevent hukommelsesforbrug

Summary: Tjenesten resourcesvc kan fortsætte med at genstarte, hvis årsagen til overdrevent hukommelsesforbrug ikke løses.

This article applies to This article does not apply to This article is not tied to any specific product. Not all product versions are identified in this article.

Symptoms

Seneste opdateringer af ILM-politikker
 
Resourcesvc genstarter konstant:

admin@node1:~> svc_node services -sr
svc_node v1.1.0 (svc_tools v1.6.6)                 Started 2019-11-20 18:32:20


Total Restarts on each node (all services) from 7 hours ago to now:

Node          # Service Restarts
--------------------------------

169.254.1.1                    1
169.254.1.2                   84
169.254.1.3                    1
169.254.1.4                   43
169.254.1.5                   51
169.254.1.6                   72
169.254.1.7                    0
169.254.1.8                   13

Aggregate restarts on nodes 'all':

Time              blbsvc  cm      crdsvc  datahd  dtq     evntsv  georcv  metrng  objctl  portal  rm      rsrcsv  sr      ss      ssm     stat    vnest
--------------------------------------------------------------------------------------------------------------------------------------------------------

2019-11-20 11:xx  -       -       -       -       -       -       -       -       -       -       -       38      -       -       -       -       -
2019-11-20 12:xx  -       -       -       -       -       -       -       -       -       -       -       36      -       -       -       -       -
2019-11-20 13:xx  -       -       -       -       -       -       -       -       -       -       -       30      -       -       -       -       -

RR eller RT DT er, der hopper mellem klar og ikke-klar

admin@Rack1Node1:~> svc_dt check

svc_dt v1.0.20 (svc_tools v1.6.6)                 Started 2019-11-20 19:32:48

Date                     Total DT       Unknown #      Unready #      Check type     Time since check

2019-11-20 19:28:01      1920           0              58             AutoCheck      4m 47s
2019-11-20 19:22:31      1920           2              46             AutoCheck      10m 17s
2019-11-20 19:16:41      1920           0              0              AutoCheck      16m 7s
2019-11-20 19:11:26      1920           0              16             AutoCheck      21m 22s
                           BR1     BR2     CT1     CT2     ET0     LS0     MA0     MR0     OB0     PR1     PR2     RR0     RT0     SS1     SS2     TT0
Date                     Unk Unr|Unk Unr|Unk Unr|Unk Unr|Unk Unr|Unk Unr|Unk Unr|Unk Unr|Unk Unr|Unk Unr|Unk Unr|Unk Unr|Unk Unr|Unk Unr|Unk Unr|Unk Unr|

2019-11-20 19:28:01      0   0  |0   0  |0   0  |0   0  |0   0  |0   0  |0   0  |0   0  |0   0  |0   0  |0   0  |0   0  |0   58 |0   0  |0   0  |0   0  |
2019-11-20 19:22:31      0   0  |0   0  |0   0  |0   0  |0   0  |0   0  |0   0  |0   0  |0   0  |0   0  |0   0  |0   0  |2   46 |0   0  |0   0  |0   0  |

Resourcesvc-loggen viser lignende hukommelsesproblemer:

169.254.1.1 2019-11-15T20:03:16,427 [Thread-16] ERROR ProcessMonitor.java (line 264) heap memory usage (99%) exceeded threshold (85%)
169.254.1.1 2019-11-15T20:03:16,428 [Thread-16] ERROR ServiceMemoryListener.java (line 47) WSCritical. Memory usage threshold exceeded. usedMemory=1028612296, percentageUsed=99.09949521251302

Klient oplever indlæsning af brugergrænsefladesider

Kontrollér, at tjenesten genstarter over /var/log/warn i objektets primære container.
# svc_exec -c "grep restart /var/log/warn | tail -2"

admin@ecsnode1:~>  svc_exec -c "grep restart /var/log/warn | tail -2"
svc_exec v1.0.6 (svc_tools v2.11.1)                 Started 2023-04-27 18:01:41

Output from node: r1n1 (object-main)                  retval: 0
2023-04-27T17:56:56.028973+00:00 gf01rsso833v-pub01 monitor: Process /opt/storageos/bin/resourcesvc is restarting.
2023-04-27T17:59:18.281755+00:00 gf01rsso833v-pub01 monitor: Process /opt/storageos/bin/resourcesvc is restarting.

Output from node: r1n2 (object-main)                  retval: 0
2023-04-27T17:44:17.243145+00:00 gf01rsso833v-pub02 monitor: Process /opt/storageos/bin/resourcesvc is restarting.
2023-04-27T17:51:58.026469+00:00 gf01rsso833v-pub02 monitor: Process /opt/storageos/bin/resourcesvc is restarting.

Output from node: r1n3 (object-main)                  retval: 0
2023-04-27T17:49:30.865189+00:00 gf01rsso833v-pub03 monitor: Process /opt/storageos/bin/resourcesvc is restarting.
2023-04-27T17:57:22.368574+00:00 gf01rsso833v-pub03 monitor: Process /opt/storageos/bin/resourcesvc is restarting.

Output from node: r1n4 (object-main)                  retval: 0
2023-04-27T17:40:11.327713+00:00 gf01rsso833v-pub04 monitor: Process /opt/storageos/bin/resourcesvc is restarting.
2023-04-27T17:59:24.566502+00:00 gf01rsso833v-pub04 monitor: Process /opt/storageos/bin/resourcesvc is restarting.

Output from node: r1n5 (object-main)                  retval: 0
2023-04-27T17:50:35.589292+00:00 gf01rsso833v-pub05 monitor: Process /opt/storageos/bin/resourcesvc is restarting.
2023-04-27T18:01:09.344803+00:00 gf01rsso833v-pub05 monitor: Process /opt/storageos/bin/resourcesvc is restarting.

Output from node: r1n6 (object-main)                  retval: 0
2023-04-27T17:39:39.480222+00:00 gf01rsso833v-pub06 monitor: Process /opt/storageos/bin/resourcesvc is restarting.
2023-04-27T17:51:49.229058+00:00 gf01rsso833v-pub06 monitor: Process /opt/storageos/bin/resourcesvc is restarting.

Output from node: r1n7 (object-main)                  retval: 0
2023-04-27T17:58:08.383501+00:00 gf01rsso833v-pub07 monitor: Process /opt/storageos/bin/resourcesvc is restarting.
2023-04-27T18:00:00.346869+00:00 gf01rsso833v-pub07 monitor: Process /opt/storageos/bin/resourcesvc is restarting.

Output from node: r1n8 (object-main)                  retval: 0
2023-04-27T17:41:11.263187+00:00 gf01rsso833v-pub08 monitor: Process /opt/storageos/bin/resourcesvc is restarting.
2023-04-27T18:00:10.438252+00:00 gf01rsso833v-pub08 monitor: Process /opt/storageos/bin/resourcesvc is restarting.

Cause

Resourcesvc-hukommelsen kan påvirkes af overforbrug af ILM-politikker.

Resolution

Åbn en serviceanmodning hos ECS-support for at få problemet undersøgt med henvisning til denne KB.

Affected Products

ECS Appliance, ECS Software
Article Properties
Article Number: 000063163
Article Type: Solution
Last Modified: 26 Sept 2025
Version:  5
Find answers to your questions from other Dell users
Support Services
Check if your device is covered by Support Services.