Dell Unity: ERROR_CODE=platform::에 대해 PUHC가 실패했습니다check_for_hardware_faults_2
Summary: ERROR_CODE=platform::에 대한 Dell Unity PUHC(Pre Upgrade Health Check)가 실패했습니다check_for_hardware_faults_2
This article applies to
This article does not apply to
This article is not tied to any specific product.
Not all product versions are identified in this article.
Symptoms
Dell Unity PUHC failed for ERROR_CODE = platform::check_for_hardware_faults_2
One or more errors have occurred. Follow the instructions provided to correct the problem and try again. Upgrade cannot proceed. -------------------------------------Errors------------------------------------- Platform: Check for hardware faults A power supply hardware fault (AC Power Loss) detected on: spb Action : Check you power cables. If correct, contact your online portal for replacement instructions. ERROR_CODE=platform::check_for_hardware_faults_2|Error|spb Platform: Check for enclosure faults A fault in the DPE enclosure was detected Action : Contact your online portal for corrective instructions. ERROR_CODE=platform::check_for_enclosure_faults_2|Error| --------------------------------------------------------------------------------
Cause
업그레이드 전 상태 점검의 일환으로 다음 구성 요소의 하드웨어 상태를 검사합니다.
전원 공급 장치
배터리 백업 장치
팬
DPEDAE
플랫폼::check_for_hardware_faults_2 오류는 DPE 인클로저에서 장애가 감지되었음을 나타냅니다.
위의 예에서 특정 문제는 spb에서 감지된 전원 공급 장치 하드웨어 장애(AC 전원 손실)입니다.
전원 공급 장치
배터리 백업 장치
팬
DPEDAE
플랫폼::check_for_hardware_faults_2 오류는 DPE 인클로저에서 장애가 감지되었음을 나타냅니다.
위의 예에서 특정 문제는 spb에서 감지된 전원 공급 장치 하드웨어 장애(AC 전원 손실)입니다.
Resolution
장애가 발생한 하드웨어에 대한 GUI 알림 및 데이터 수집을 확인하고 필요에 따라 교체합니다.
이 예에서는 DPE 전원 공급 장치 B0에 전원이 공급되지 않으며 교체할 준비가 되었습니다.
TRiiAGE_full_SPlogs.txt
A 04/29/24 09:53:25.471 espkg 1670066 [INFO] System: PS_MGMT CacheStatus changes from: OK to DEGRADED. B 04/29/24 09:53:28.451 Bus0 Enc0 PowB 1678006 [ERROR] System: Power Supply is Faulted (GenFlt/AcFail ). B 04/29/24 09:53:28.458 espkg 1670066 [INFO] System: PS_MGMT CacheStatus changes from: OK to DEGRADED. B 04/29/24 09:53:48.597 DGSSP 1 [INFO] System: 04/29/2024 09:53:07 | BMC Power Supply Status | PS1_Status | External Fault | Asserted ELOG(632) 0x79 : 0xB800 0x7E : 0x00 0x80 : 0x08 0x01 : 0x80 0x02 : 0x15 0x79 : 0xB800 0x7E : 0x00 0x80 : 0x08 0x01 : 0x80 0x02 : 0x15 0x79 : 0xB800 0x7E : 0x00 0x80 : 0x08 0x01 : 0x80 0x02 : 0x15 0x79 : 0x0000 0x7E : 0x00 0x80 : 0x10 0x01 : 0x80 0x02 : 0x15 0x79 : 0x0800 0x7E : 0x00 0x80 : 0x10 0x01 : 0x80 0x02 : 0x15 0x79 : 0x8000 0x7E : 0x00 0x80 : 0x10 0x01 : 0x80 0x02 : 0x15 0x79 : 0x0000 0x7E : 0x00 0x80 : 0x10 0x01 : 0x80 0x02 : 0x15 0x79 : 0x0000 0x7E : 0x00 0x80 : 0x10 0x01 : 0x80 0x02 : 0x15 0x79 : 0x0000 0x7E : 0x00 0x80 : 0x10 0x01 : 0x80 0x02 : 0x15 0x79 : 0x0000 0x7E : 0x00 0x80 : 0x10 0x01 : 0x80 0x02 : 0x15 A 04/29/24 09:54:15.409 DGSSP 1 [INFO] System: 04/29/2024 09:53:06 | BMC Power Supply Status | PSB_Status | External Fault | Asserted ELOG(632) 0x79 : 0xB800 0x7E : 0x00 0x80 : 0x08 0x01 : 0x80 0x02 : 0x15 0x79 : 0xB800 0x7E : 0x00 0x80 : 0x08 0x01 : 0x80 0x02 : 0x15 0x79 : 0xB800 0x7E : 0x00 0x80 : 0x08 0x01 : 0x80 0x02 : 0x15 0x79 : 0x0000 0x7E : 0x00 0x80 : 0x10 0x01 : 0x80 0x02 : 0x15 0x79 : 0x0800 0x7E : 0x00 0x80 : 0x10 0x01 : 0x80 0x02 : 0x15 0x79 : 0x8000 0x7E : 0x00 0x80 : 0x10 0x01 : 0x80 0x02 : 0x15 0x79 : 0x0000 0x7E : 0x00 0x80 : 0x10 0x01 : 0x80 0x02 : 0x15 0x79 : 0x0000 0x7E : 0x00 0x80 : 0x10 0x01 : 0x80 0x02 : 0x15 0x79 : 0x0000 0x7E : 0x00 0x80 : 0x10 0x01 : 0x80 0x02 : 0x15 0x79 : 0x0000 0x7E : 0x00 0x80 : 0x10 0x01 : 0x80 0x02 : 0x15 B 04/29/24 09:54:16.285 Health 601f4 [CRIT] User: Power supply DPE Power Supply B0 is not receiving power B 04/29/24 09:54:16.465 Health 60516 [ERROR] User: System dsus017d2-un32 has experienced one or more problems that have had a major impact.
SPB_fbecli_exe_ccollectall.txt
---------------------------------------------------------------- FBECLI> sptime: Current Time: 05/16/24 10:08:26.283 SP TimeStamp: 14267394886ms ---------------------------------------------------------------- FBECLI> spstat: SP B [Passive SP] PEER SP: PRESENT HW Cache Status: DEGRADED Reason: PS Physical memory: SPA(65536 MB), SPB(65536 MB) DPE-MIRANDA 0 (Bus 0, Pos 0) -OK EnclFaultLedStatus: ON EnclFaultLedReason: PS Fault PS A B OK (0214) FLT (0214)
Affected Products
Dell EMC Unity, Dell EMC Unity Family |Dell EMC Unity All Flash, Dell EMC Unity Family, Dell EMC Unity Hybrid, Dell Unity Operating Environment (OE)Article Properties
Article Number: 000228125
Article Type: Solution
Last Modified: 29 Jul 2025
Version: 4