Dell Unity: PUHC mislukt voor ERROR_CODE=platform::check_for_hardware_faults_2
Summary: Dell Unity PUHC (Pre-upgrade healthcheck) mislukt voor ERROR_CODE=platform::check_for_hardware_faults_2
This article applies to
This article does not apply to
This article is not tied to any specific product.
Not all product versions are identified in this article.
Symptoms
Dell Unity PUHC mislukt voor ERROR_CODE = platform::check_for_hardware_faults_2
One or more errors have occurred. Follow the instructions provided to correct the problem and try again. Upgrade cannot proceed. -------------------------------------Errors------------------------------------- Platform: Check for hardware faults A power supply hardware fault (AC Power Loss) detected on: spb Action : Check you power cables. If correct, contact your online portal for replacement instructions. ERROR_CODE=platform::check_for_hardware_faults_2|Error|spb Platform: Check for enclosure faults A fault in the DPE enclosure was detected Action : Contact your online portal for corrective instructions. ERROR_CODE=platform::check_for_enclosure_faults_2|Error| --------------------------------------------------------------------------------
Cause
Als onderdeel van de healthcheck voorafgaand aan de upgrade worden de hardwarestatussen van de volgende componenten onderzocht:
Voedingen
Noodvoedingen Back-upbatterij Ventilatoren
DPE
DAE
De platform::check_for_hardware_faults_2 fout geeft aan dat er een fout in de DPE-behuizing is gedetecteerd.
In het bovenstaande voorbeeld is het specifieke probleem een hardwarefout van de voeding (AC Power Loss) die is gedetecteerd op: spb
Voedingen
Noodvoedingen Back-upbatterij Ventilatoren
DPE
DAE
De platform::check_for_hardware_faults_2 fout geeft aan dat er een fout in de DPE-behuizing is gedetecteerd.
In het bovenstaande voorbeeld is het specifieke probleem een hardwarefout van de voeding (AC Power Loss) die is gedetecteerd op: spb
Resolution
Controleer de GUI-waarschuwingen en verzamelde data op defecte hardware en vervang deze indien nodig.
In dit voorbeeld krijgt de DPE-voeding B0 geen voeding en is deze klaar voor vervanging.
TRiiAGE_full_SPlogs.txt
A 04/29/24 09:53:25.471 espkg 1670066 [INFO] System: PS_MGMT CacheStatus changes from: OK to DEGRADED. B 04/29/24 09:53:28.451 Bus0 Enc0 PowB 1678006 [ERROR] System: Power Supply is Faulted (GenFlt/AcFail ). B 04/29/24 09:53:28.458 espkg 1670066 [INFO] System: PS_MGMT CacheStatus changes from: OK to DEGRADED. B 04/29/24 09:53:48.597 DGSSP 1 [INFO] System: 04/29/2024 09:53:07 | BMC Power Supply Status | PS1_Status | External Fault | Asserted ELOG(632) 0x79 : 0xB800 0x7E : 0x00 0x80 : 0x08 0x01 : 0x80 0x02 : 0x15 0x79 : 0xB800 0x7E : 0x00 0x80 : 0x08 0x01 : 0x80 0x02 : 0x15 0x79 : 0xB800 0x7E : 0x00 0x80 : 0x08 0x01 : 0x80 0x02 : 0x15 0x79 : 0x0000 0x7E : 0x00 0x80 : 0x10 0x01 : 0x80 0x02 : 0x15 0x79 : 0x0800 0x7E : 0x00 0x80 : 0x10 0x01 : 0x80 0x02 : 0x15 0x79 : 0x8000 0x7E : 0x00 0x80 : 0x10 0x01 : 0x80 0x02 : 0x15 0x79 : 0x0000 0x7E : 0x00 0x80 : 0x10 0x01 : 0x80 0x02 : 0x15 0x79 : 0x0000 0x7E : 0x00 0x80 : 0x10 0x01 : 0x80 0x02 : 0x15 0x79 : 0x0000 0x7E : 0x00 0x80 : 0x10 0x01 : 0x80 0x02 : 0x15 0x79 : 0x0000 0x7E : 0x00 0x80 : 0x10 0x01 : 0x80 0x02 : 0x15 A 04/29/24 09:54:15.409 DGSSP 1 [INFO] System: 04/29/2024 09:53:06 | BMC Power Supply Status | PSB_Status | External Fault | Asserted ELOG(632) 0x79 : 0xB800 0x7E : 0x00 0x80 : 0x08 0x01 : 0x80 0x02 : 0x15 0x79 : 0xB800 0x7E : 0x00 0x80 : 0x08 0x01 : 0x80 0x02 : 0x15 0x79 : 0xB800 0x7E : 0x00 0x80 : 0x08 0x01 : 0x80 0x02 : 0x15 0x79 : 0x0000 0x7E : 0x00 0x80 : 0x10 0x01 : 0x80 0x02 : 0x15 0x79 : 0x0800 0x7E : 0x00 0x80 : 0x10 0x01 : 0x80 0x02 : 0x15 0x79 : 0x8000 0x7E : 0x00 0x80 : 0x10 0x01 : 0x80 0x02 : 0x15 0x79 : 0x0000 0x7E : 0x00 0x80 : 0x10 0x01 : 0x80 0x02 : 0x15 0x79 : 0x0000 0x7E : 0x00 0x80 : 0x10 0x01 : 0x80 0x02 : 0x15 0x79 : 0x0000 0x7E : 0x00 0x80 : 0x10 0x01 : 0x80 0x02 : 0x15 0x79 : 0x0000 0x7E : 0x00 0x80 : 0x10 0x01 : 0x80 0x02 : 0x15 B 04/29/24 09:54:16.285 Health 601f4 [CRIT] User: Power supply DPE Power Supply B0 is not receiving power B 04/29/24 09:54:16.465 Health 60516 [ERROR] User: System dsus017d2-un32 has experienced one or more problems that have had a major impact.
SPB_fbecli_exe_ccollectall.txt
---------------------------------------------------------------- FBECLI> sptime: Current Time: 05/16/24 10:08:26.283 SP TimeStamp: 14267394886ms ---------------------------------------------------------------- FBECLI> spstat: SP B [Passive SP] PEER SP: PRESENT HW Cache Status: DEGRADED Reason: PS Physical memory: SPA(65536 MB), SPB(65536 MB) DPE-MIRANDA 0 (Bus 0, Pos 0) -OK EnclFaultLedStatus: ON EnclFaultLedReason: PS Fault PS A B OK (0214) FLT (0214)
Affected Products
Dell EMC Unity, Dell EMC Unity Family |Dell EMC Unity All Flash, Dell EMC Unity Family, Dell EMC Unity Hybrid, Dell Unity Operating Environment (OE)Article Properties
Article Number: 000228125
Article Type: Solution
Last Modified: 29 Jul 2025
Version: 4
Find answers to your questions from other Dell users
Support Services
Check if your device is covered by Support Services.