Symptoms
Dell Unity PUHC, ERROR_CODE = platform::check_for_hardware_faults_2 için başarısız oldu
One or more errors have occurred. Follow the instructions provided to correct the problem and try again. Upgrade cannot proceed. -------------------------------------Errors------------------------------------- Platform: Check for hardware faults A power supply hardware fault (AC Power Loss) detected on: spb Action : Check you power cables. If correct, contact your online portal for replacement instructions. ERROR_CODE=platform::check_for_hardware_faults_2|Error|spb Platform: Check for enclosure faults A fault in the DPE enclosure was detected Action : Contact your online portal for corrective instructions. ERROR_CODE=platform::check_for_enclosure_faults_2|Error| --------------------------------------------------------------------------------
Cause
Yükseltme öncesi durum kontrolünün bir parçası olarak aşağıdaki bileşenlerin donanım durumları incelenir: Güç kaynakları,
Pil yedekleme birimleri
, Fanlar
DPE
, DAE
Platform::check_for_hardware_faults_2 hatası, DPE muhafazasında bir arıza tespit edildiğini gösterir.
Yukarıdaki örnekte söz konusu sorun, SPB üzerinde tespit edilen güç kaynağı donanım arızasıdır (AC Güç Kaybı).
Pil yedekleme birimleri
, Fanlar
DPE
, DAE
Platform::check_for_hardware_faults_2 hatası, DPE muhafazasında bir arıza tespit edildiğini gösterir.
Yukarıdaki örnekte söz konusu sorun, SPB üzerinde tespit edilen güç kaynağı donanım arızasıdır (AC Güç Kaybı).
Resolution
GUI uyarılarını ve toplanan verileri, arızalı donanım olup olmadığını kontrol edin ve gerekirse değiştirin.
Bu örnekte, DPE Güç Kaynağı B0 güç almıyor ve değiştirilmeye hazır.
TRiiAGE_full_SPlogs.txt
A 04/29/24 09:53:25.471 espkg 1670066 [INFO] System: PS_MGMT CacheStatus changes from: OK to DEGRADED. B 04/29/24 09:53:28.451 Bus0 Enc0 PowB 1678006 [ERROR] System: Power Supply is Faulted (GenFlt/AcFail ). B 04/29/24 09:53:28.458 espkg 1670066 [INFO] System: PS_MGMT CacheStatus changes from: OK to DEGRADED. B 04/29/24 09:53:48.597 DGSSP 1 [INFO] System: 04/29/2024 09:53:07 | BMC Power Supply Status | PS1_Status | External Fault | Asserted ELOG(632) 0x79 : 0xB800 0x7E : 0x00 0x80 : 0x08 0x01 : 0x80 0x02 : 0x15 0x79 : 0xB800 0x7E : 0x00 0x80 : 0x08 0x01 : 0x80 0x02 : 0x15 0x79 : 0xB800 0x7E : 0x00 0x80 : 0x08 0x01 : 0x80 0x02 : 0x15 0x79 : 0x0000 0x7E : 0x00 0x80 : 0x10 0x01 : 0x80 0x02 : 0x15 0x79 : 0x0800 0x7E : 0x00 0x80 : 0x10 0x01 : 0x80 0x02 : 0x15 0x79 : 0x8000 0x7E : 0x00 0x80 : 0x10 0x01 : 0x80 0x02 : 0x15 0x79 : 0x0000 0x7E : 0x00 0x80 : 0x10 0x01 : 0x80 0x02 : 0x15 0x79 : 0x0000 0x7E : 0x00 0x80 : 0x10 0x01 : 0x80 0x02 : 0x15 0x79 : 0x0000 0x7E : 0x00 0x80 : 0x10 0x01 : 0x80 0x02 : 0x15 0x79 : 0x0000 0x7E : 0x00 0x80 : 0x10 0x01 : 0x80 0x02 : 0x15 A 04/29/24 09:54:15.409 DGSSP 1 [INFO] System: 04/29/2024 09:53:06 | BMC Power Supply Status | PSB_Status | External Fault | Asserted ELOG(632) 0x79 : 0xB800 0x7E : 0x00 0x80 : 0x08 0x01 : 0x80 0x02 : 0x15 0x79 : 0xB800 0x7E : 0x00 0x80 : 0x08 0x01 : 0x80 0x02 : 0x15 0x79 : 0xB800 0x7E : 0x00 0x80 : 0x08 0x01 : 0x80 0x02 : 0x15 0x79 : 0x0000 0x7E : 0x00 0x80 : 0x10 0x01 : 0x80 0x02 : 0x15 0x79 : 0x0800 0x7E : 0x00 0x80 : 0x10 0x01 : 0x80 0x02 : 0x15 0x79 : 0x8000 0x7E : 0x00 0x80 : 0x10 0x01 : 0x80 0x02 : 0x15 0x79 : 0x0000 0x7E : 0x00 0x80 : 0x10 0x01 : 0x80 0x02 : 0x15 0x79 : 0x0000 0x7E : 0x00 0x80 : 0x10 0x01 : 0x80 0x02 : 0x15 0x79 : 0x0000 0x7E : 0x00 0x80 : 0x10 0x01 : 0x80 0x02 : 0x15 0x79 : 0x0000 0x7E : 0x00 0x80 : 0x10 0x01 : 0x80 0x02 : 0x15 B 04/29/24 09:54:16.285 Health 601f4 [CRIT] User: Power supply DPE Power Supply B0 is not receiving power B 04/29/24 09:54:16.465 Health 60516 [ERROR] User: System dsus017d2-un32 has experienced one or more problems that have had a major impact.
SPB_fbecli_exe_ccollectall.txt
---------------------------------------------------------------- FBECLI> sptime: Current Time: 05/16/24 10:08:26.283 SP TimeStamp: 14267394886ms ---------------------------------------------------------------- FBECLI> spstat: SP B [Passive SP] PEER SP: PRESENT HW Cache Status: DEGRADED Reason: PS Physical memory: SPA(65536 MB), SPB(65536 MB) DPE-MIRANDA 0 (Bus 0, Pos 0) -OK EnclFaultLedStatus: ON EnclFaultLedReason: PS Fault PS A B OK (0214) FLT (0214)
Affected Products
Dell EMC Unity, Dell EMC Unity Family |Dell EMC Unity All Flash, Dell EMC Unity Family, Dell EMC Unity Hybrid, Dell Unity Operating Environment (OE)Article Properties
Article Number: 000228125