MFE ConGroup: Performing an AutoSwap and received AbendS0C4-11 in CGRPQDEV, error message: GDDR322E
Summary: Performing an AutoSwap and received AbendS0C4-11 in CGRPQDEV. When using GDDR PA21 script, message GDDR322E is received.
This article applies to
This article does not apply to
This article is not tied to any specific product.
Not all product versions are identified in this article.
Symptoms
During a DR test, ConGroup on non-owner LPAR abended with S0C4-11 during refresh after a swap back.
When using GDDR PA21 script, message GDDR322E is received.
When using GDDR PA21 script, message GDDR322E is received.
+GDDR322E GDDR ConGroup congroup_REFRESH function failed, rc 16 +GDDR639I GDDR Completed Handle ConGroup Groups with rc 16 +GDDR721I GDDR Starting Script Function Call Stats +GDDR639I GDDR Function Status ===> 340
Cause
AbendS0C4 in CGRPQDEV when AutoSwap passes in a stale address of the ConGroup global block. TPROT test was incorrect - allowing access to invalid storage.
Resolution
Logic changed to allow fetch access to store-protected storage. Stale addresses will now be correctly refreshed.
Permanent Fix:
Permanent Fix:
-
For Mainframe Enablers 8.5, PTF SF85089 has been developed to correct the issue. It is available to download from Dell Online Support
- For Mainframe Enablers 8.4, PTF SF84140 has been developed to correct the issue. It is available to download from Dell Online Support
Additional Information
Addressing PTF (from PTF cover note):
++PTF(SF85089) REWORK(2021302) .
++VER(Z038) FMID(SSCF850)
/*
*-------------------------------------------------------------
* PROBLEM DESCRIPTION(S):
* ------------------------------------------------------------
* PROBLEM FIXED: OPT 589935
* USERS AFFECTED: AutoSwap Users
* PROBLEM DESCRIPTION: AbendS0C4-11 in CGRPQDEV
* DESCRIPTION DETAIL:
*
* AbendS0C4 in CGRPQDEV when AutoSwap passes in a stale
* address of the ConGroup global block. TPROT test was
* incorrect - allowing access to invalid storage.
*
* PROBLEM RESOLUTION:
*
* Logic changed to allow fetch access to store-protected
* storage. Stale addresses will now be correctly refreshed.
* TPROT test was changed to use caller key instead of key 0
* and succeed on CC 0 and CC 1 (not just CC 0).
*
* MODULES: CGRPQDEV
*
* ------------------------------------------------------------
* SF85089 29 Oct 2021 13:05:52
* ------------------------------------------------------------
* OPT Summary
* The following OPT was addressed by this PTF:
*
* 589935
*
*-------------------------------------------------------------
++PTF(SF85089) REWORK(2021302) .
++VER(Z038) FMID(SSCF850)
/*
*-------------------------------------------------------------
* PROBLEM DESCRIPTION(S):
* ------------------------------------------------------------
* PROBLEM FIXED: OPT 589935
* USERS AFFECTED: AutoSwap Users
* PROBLEM DESCRIPTION: AbendS0C4-11 in CGRPQDEV
* DESCRIPTION DETAIL:
*
* AbendS0C4 in CGRPQDEV when AutoSwap passes in a stale
* address of the ConGroup global block. TPROT test was
* incorrect - allowing access to invalid storage.
*
* PROBLEM RESOLUTION:
*
* Logic changed to allow fetch access to store-protected
* storage. Stale addresses will now be correctly refreshed.
* TPROT test was changed to use caller key instead of key 0
* and succeed on CC 0 and CC 1 (not just CC 0).
*
* MODULES: CGRPQDEV
*
* ------------------------------------------------------------
* SF85089 29 Oct 2021 13:05:52
* ------------------------------------------------------------
* OPT Summary