PowerFlex SDC-er har I/O-feil etter at ny SDS er lagt til i klynge
Summary: Når du har lagt til et nytt SDS i PowerFlex-klyngen og rebalansert data i det nye SDS, viser noen SDC-er I/O-feil
Symptoms
- SDS ble lagt til klyngen (fra MDM-hendelser)
2022-03-07 18:28:07.080 MDM_CLI_CONF_COMMAND_RECEIVED INFO Command add_sds received, User: 'admin'. [4576114] protection_domain with ID a876543f00000000, fault_set N/A, New SDS name: sds12, Hostnames: 172.1.0.12, Port: 7072 2022-03-07 18:28:07.324 CLI_COMMAND_SUCCEEDED INFO Command add_sds succeeded. [4576114] ID: 7d120650000002f
- SDC-logger viser kjernestakkspor i forsøket på å koble til det nye SDS. Disse kan vises flere ganger når SDC prøver å koble til den nye SDS:
022-03-07T18:29:02.880040-05:00 sdc32 kernel: net_sched: page allocation failure: order:4, mode:0x104020 2022-03-07T18:29:02.880170-05:00 sdc32 kernel: CPU: 16 PID: 5662 Comm: net_sched Kdump: loaded Tainted: P OE ------------ 3.10.0-1062.el7.x86_64 #1 2022-03-07T18:29:02.880242-05:00 sdc32 kernel: Hardware name: Dell Inc. PowerEdge R740xd/5XXXXX, BIOS 2.4.8 11/26/2019 2022-03-07T18:29:02.880355-05:00 sdc32 kernel: Call Trace: 2022-03-07T18:29:02.880453-05:00 sdc32 kernel: [<ffffffffbb179262>] dump_stack+0x19/0x1b 2022-03-07T18:29:02.880553-05:00 sdc32 kernel: [<ffffffffbabc23d0>] warn_alloc_failed+0x110/0x180 2022-03-07T18:29:02.880623-05:00 sdc32 kernel: [<ffffffffbb1747fc>] __alloc_pages_slowpath+0x6b6/0x724 2022-03-07T18:29:02.880709-05:00 sdc32 kernel: [<ffffffffc09c021e>] ? netAddress_ToStrCopy+0x2de/0x520 [scini] 2022-03-07T18:29:02.880787-05:00 sdc32 kernel: [<ffffffffbabc6b84>] __alloc_pages_nodemask+0x404/0x420 2022-03-07T18:29:02.880851-05:00 sdc32 kernel: [<ffffffffbac14c68>] alloc_pages_current+0x98/0x110 2022-03-07T18:29:02.880922-05:00 sdc32 kernel: [<ffffffffbabc117e>] __get_free_pages+0xe/0x40 2022-03-07T18:29:02.880995-05:00 sdc32 kernel: [<ffffffffbac2052e>] kmalloc_order_trace+0x2e/0xa0 2022-03-07T18:29:02.881053-05:00 sdc32 kernel: [<ffffffffbac24571>] __kmalloc+0x211/0x230 2022-03-07T18:29:02.881110-05:00 sdc32 kernel: [<ffffffffc0988274>] mapClass_AllocAndInitObj+0x44/0x140 [scini] 2022-03-07T18:29:02.881167-05:00 sdc32 kernel: [<ffffffffc098959e>] mapClass_UpdateAll+0x40e/0x9b0 [scini] 2022-03-07T18:29:02.881229-05:00 sdc32 kernel: [<ffffffffc09c9994>] ? mosMitSchedThrd_CurThrdOurs+0x64/0x90 [scini] 2022-03-07T18:29:02.881298-05:00 sdc32 kernel: [<ffffffffc099aa07>] mapMdm_HandleObjUpdate_CK+0x327/0x730 [scini] 2022-03-07T18:29:02.881360-05:00 sdc32 kernel: [<ffffffffc099c070>] ? mapMdm_SendUpdateReq_CK+0xf0/0xed0 [scini] 2022-03-07T18:29:02.881419-05:00 sdc32 kernel: [<ffffffffc099c4b0>] mapMdm_SendUpdateReq_CK+0x530/0xed0 [scini] 2022-03-07T18:29:02.881480-05:00 sdc32 kernel: [<ffffffffc09a704f>] ? netSock_DoIO+0xef/0x7d0 [scini] 2022-03-07T18:29:02.881543-05:00 sdc32 kernel: [<ffffffffc09aaf47>] ? netChanThrottler_TryToWakeupWaiterOfCond+0x27/0x100 [scini] 2022-03-07T18:29:02.881606-05:00 sdc32 kernel: [<ffffffffc09ab118>] ? netChanThrottler_TryToWakeupWaiter+0x58/0x80 [scini] 2022-03-07T18:29:02.881660-05:00 sdc32 kernel: [<ffffffffc095cc80>] ? netChan_SendReq_CK+0x90/0xa70 [scini] 2022-03-07T18:29:02.881716-05:00 sdc32 kernel: [<ffffffffc095cdd0>] netChan_SendReq_CK+0x1e0/0xa70 [scini] 2022-03-07T18:29:02.881775-05:00 sdc32 kernel: [<ffffffffc09699c5>] netCon_SendReq_CK+0x175/0x590 [scini] 2022-03-07T18:29:02.881835-05:00 sdc32 kernel: [<ffffffffc0963cf7>] ? netRPC_SendDone_CK+0x47/0xab0 [scini] 2022-03-07T18:29:02.881890-05:00 sdc32 kernel: [<ffffffffc0963dd3>] netRPC_SendDone_CK+0x123/0xab0 [scini] 2022-03-07T18:29:02.881959-05:00 sdc32 kernel: [<ffffffffc09c9c24>] mosMit_RunWithTLS+0x54/0x60 [scini] 2022-03-07T18:29:02.882017-05:00 sdc32 kernel: [<ffffffffc09cbb92>] mosMitSchedThrd_ThrdEntry+0x1a2/0x500 [scini] 2022-03-07T18:29:02.882071-05:00 sdc32 kernel: [<ffffffffc09c82f0>] ? mosTicks_DestroyEnvSpecific+0x10/0x10 [scini] 2022-03-07T18:29:02.882126-05:00 sdc32 kernel: [<ffffffffc09c8310>] mosOsThrd_Entry+0x20/0x50 [scini] 2022-03-07T18:29:02.882185-05:00 sdc32 kernel: [<ffffffffbaac50d1>] kthread+0xd1/0xe0 2022-03-07T18:29:02.882240-05:00 sdc32 kernel: [<ffffffffbaac5000>] ? insert_kthread_work+0x40/0x40 2022-03-07T18:29:02.882294-05:00 sdc32 kernel: [<ffffffffbb18bd37>] ret_from_fork_nospec_begin+0x21/0x21 2022-03-07T18:29:02.882351-05:00 sdc32 kernel: [<ffffffffbaac5000>] ? insert_kthread_work+0x40/0x40 2022-03-07T18:29:02.891431-05:00 sdc32 kernel: ScaleIO mapClass_AllocAndInitObj:1301 :Error: Failed to allocate memory 38480.Cannot process MDM response
- SDC-logger viser da I/O-feil:
2022-03-07T18:49:03.652009-05:00 sdc32 kernel: ScaleIO mapMultiHead_UpdateInPlace:561 :Warning: Invalid primaryTgtIdx 47 at 2. Multi-head ID dd990042. 2022-03-07T18:49:03.652130-05:00 sdc32 kernel: ScaleIO mapClass_UpdateAll:614 :Error: Object ffff948c7f350000 (class multi_head) failed to update in place.status NO_RESOURCES (67) 2022-03-07T18:49:04.662144-05:00 sdc32 kernel: ScaleIO mapVolIO_ReportIOErrorIfNeeded:491 :[67641433832] IO-ERROR Type READ. comb: 6ecc80210154. offsetInComb 14536800. SizeInLB 256. SDS_ID 7dd0d24700000033. Comb Gen 21c1. Head Gen 222c. StartLB 5fb1ac860. 2022-03-07T18:49:04.662268-05:00 sdc32 kernel: blk_update_request: I/O error, dev scinic, sector 25687672672
Innvirkning
I/O-feil på enkelte SDC-er
Cause
Resolution
I/O-feilene kan stoppes umiddelbart ved å sette den nye SDS i modus for øyeblikkelig vedlikehold. SDC-ene kan få dataene sine fra de gjenværende SDS-ene. Ta SDS ut av vedlikehold når SDC-minneproblemet er løst.
Det er et par ting å gjøre her, alle bør vurderes for handlingsplanen:
- Hvis en sikker metode er nødvendig for å fikse det, løser en omstart av SDC-verten problemet. Det initialiserer operativsystemet på nytt, og minnefragmenteringen som var der før, vil være borte
-
Hvis en omstart ikke er mulig, bruk følgende kommando. Den prøver å gjenvinne og komprimere det fragmenterte minnet så mye som mulig. Dette er ikke garantert å fungere og kan være forstyrrende for gjeldende applikasjoner i de få sekundene det gjenvinner / komprimerer minnefragmenter:
sync; echo 1 > /proc/sys/vm/drop_caches; echo 1 > /proc/sys/vm/compact_memory
Sjekk minnebruken med "cat / proc / buddyinfo" for å se om kommandoen ovenfor hjalp eller ikke. Bruk den før og etter å ha kjørt kommandoen ovenfor for å se om den stiger over null. Vi ser på den fjerde kolonnen i raden "Node 0, zone Normal", som er et antall sammenhengende minnebiter på 64 kB. I dette tilfellet vises det før du kjører kommandoen ovenfor for å gjenvinne/komprimere:sdc32:~ # cat /proc/buddyinfo Node 0, zone DMA 1 0 0 1 2 1 1 0 1 1 2 Node 0, zone DMA32 9 5 7 5 9 6 8 6 7 5 295 Node 0, zone Normal 909921 1263646 202478 0<=== 0 0 0 0 0 0 0 Node 1, zone Normal 39085 0 0 0 0 0 0 0 0 0 0
- Kontroller minnets overcommit-innstillinger på kjernen ved hjelp av "sysctl -a." Hvis kjernen bruker standarden som følger:
vm.overcommit_memory = 0
vm.overcommit_ratio = 50
Det ville være fordelaktig å snakke med OS-leverandøren om å endre disse parametrene som følger, for å gi operativsystemet mer minne å jobbe med etter en omstart og unngå dette problemet i fremtiden:
vm.overcommit_memory = 2
vm.overcommit_ratio = 98
- Linux-kjernen må kanskje oppgraderes hvis dette blir et vanlig mønster av fragmentering av OS-minnet
Berørte versjoner
Alle PowerFlex SDC-er kan påvirkes av problemer med fragmentering av operativsystemet.