尝试运行升级前运行状况检查时,屏幕截图中会显示一条警告。
收集的数据收集(请参阅有关如何从 Dell Unity: 阵列收集服务数据的知识库 483583 ),并对它们运行分类
TRiiAGE_SPlogs.txt文件:
B 08/29/16 08:14:03.616 UpdateProvider 180001 [INFO] User: Health check has been started. B 08/29/16 08:14:32.315 PreUpdateHealhthChk 0 [INFO] System: Msg: Key=[flr::check_if_storage_pool_recovery_is_required_3] Level=[external] Title=[Flare: Check if storage pool recovery is required ] Full Error Log=[/nas/log/check_health.160829-081403.log]
/nas/log/check_health.160829-081403.log
2016-08-29T08:14:31+00:00 check_if_storage_pool_recovery_is_required: (Pass Pass Pass Fail) .. .. .. One or more warnings have occurred. It is recommended that you follow the instructions provided to correct the problem then try again. Upgrade cannot proceed. ------------------------------------Warnings------------------------------------ Flare: Check if storage pool recovery is required The following pools do not appear to be in a healthy state: * P4, Database Prod Pool - This storage pool has exceeded the capacity threshold you specified. To allocate more storage space, add additional disks to your system. (https://W.X.Y.Z/help/webhelp/- en_US/index.htm?#unity_c_storage_pool_at_or_near_full_capacity.html) Action : Upgrade may continue, but the recommended course of action is to escalate this issue through your support organization. Provide this output with the escalation. ERROR_CODE=flr::check_if_storage_pool_recovery_is_required_3|Warning|P4, Database Prod Pool - This storage pool has exceeded the capacity threshold you specified. To allocate more storage space, add additional disks to your system. (https://W.X.Y.Z/help/webhelp/en_US/index.htm?#unity_c_storage_pool_at_or_near_full_capacity.html) -------------------------------------------------------------------------------- Check Result: Warning
Cause
在执行 TRiiAGE_SPlogs.txt 和 /nas/log/check_health.160829-081403.log 之后,可以看到 Pool P4 已超过容量阈值。
Resolution
要纠正这种情况,请执行以下作:
- 在存储下,选择池。
- 选择相关的池,然后选择编辑图标。
- 在Usage选项卡上,将警报阈值提高到高于已用量的百分比。
- 重新运行升级前运行状况检查
提醒:警报阈值是达到该值时 Unisphere 生成有关池中剩余空间量的通知的存储分配百分比。您可以将此值设置为介于 50% 和 84% 之间。
Additional Information
修改 P4 存储池的警报阈值后,这些日志将发布在TRiiAGE_SPlogs.txt中。第二次运行状况检查后未出现任何错误,这表示干净运行,没有错误或警告。
B 08/29/16 09:00:19.684 mlu 12d010c [INFO] System: The user has initiated the change of one or more properties for Storage Pool 300000005. B 08/29/16 09:00:19.697 mlu 12d010d [INFO] System: The user has successfully changed one or more properties for Storage Pool 300000005. B 08/29/16 09:00:21.756 UIS_PoolProvisioningService 540066 [INFO] Audit: User local/admin has successfully modified pool P4, Database Prod Pool. B 08/29/16 09:00:22.024 Health 60326 [INFO] User: Storage pool P4, Database Prod Pool is operating normally B 08/29/16 09:01:28.552 UpdateProvider 180001 [INFO] User: Health check has been started.
Affected Products
Dell EMC Unity FamilyProducts
Dell Unity 300, Dell EMC Unity 300F, Dell EMC Unity 400, Dell EMC Unity 400F, Dell EMC Unity 500, Dell EMC Unity 500F, Dell EMC Unity 600, Dell EMC Unity 600F, Dell EMC Unity Family |Dell EMC Unity All Flash, Dell EMC Unity Family
, Dell EMC Unity Hybrid, Dell EMC UnityVSA Professional Edition/Unity Cloud Edition
...
Article Properties
Article Number: 000052020
Article Type: Solution
Last Modified: 24 Oct 2025
Version: 5
Find answers to your questions from other Dell users
Support Services
Check if your device is covered by Support Services.