PowerScale: SyncIQ replikerer ikke tilgangstid (atime) til målklyngen
Summary: Hvis en tilgangstid for filer (atime) er endret i produksjonsklyngen når du replikerer data ved hjelp av SyncIQ. Tilgangstid (atime) replikeres ikke til målklyngen når SyncIQ fullfører replikeringen. ...
This article applies to
This article does not apply to
This article is not tied to any specific product.
Not all product versions are identified in this article.
Symptoms
Example:
Source:
SIQ1-1# stat -x /ifs/data/Sync_Test1
File: "/ifs/data/Sync_Test1"
Size: 8347045 FileType: Regular File
Mode: (0777/-rwxrwxrwx) Uid: (1001450/(1001450)) Gid: (1000069/(1000069))
Device: 136,1757282482 Inode: 4314169351 Links: 3
Access: Wed Jun 14 13:56:49 2023 <-- Access Time is newer than Target Access Time
Modify: Sun Jun 11 09:08:41 2023
Change: Sun Jun 11 09:08:41 2023
Target:
SIQ-2# stat -x /ifs/data/Sync_Test1
File: "/ifs/data/Sync_Test1"
Size: 8347045 FileType: Regular File
Mode: (0777/-rwxrwxrwx) Uid: (1000759/(1000759)) Gid: (1000195/(1000195))
Device: 18446744073709551597,18446744072263041268 Inode: 51447964289 Links: 3
Access: Sun Jun 11 09:08:35 2023 <-- Target Access time is not updated
Modify: Sun Jun 11 09:08:41 2023
Change: Sun Jun 11 10:21:48 2023Cause
SyncIQ baserer all endringsoverføring på attributter som er synlige i et øyeblikksbilde. SyncIQ kan bare overføre en gang fra kilde til mål. Når en kildefil har hatt en annen modifikasjon som utløser en COW, for eksempel en tillatelsesendring.
Resolution
Dette er tiltenkt, en forespørsel om funksjonsforbedring er sendt inn for fremtidig kode.
Article Properties
Article Number: 000215411
Article Type: Solution
Last Modified: 02 Jan 2026
Version: 2
Find answers to your questions from other Dell users
Support Services
Check if your device is covered by Support Services.