PowerScale: SyncIQ replikerer ikke tilgangstid (atime) til målklyngen

Summary: Hvis en tilgangstid for filer (atime) er endret i produksjonsklyngen når du replikerer data ved hjelp av SyncIQ. Tilgangstid (atime) replikeres ikke til målklyngen når SyncIQ fullfører replikeringen. ...

This article applies to This article does not apply to This article is not tied to any specific product. Not all product versions are identified in this article.

Symptoms

Example:
 

Source:
SIQ1-1# stat -x /ifs/data/Sync_Test1
  File: "/ifs/data/Sync_Test1"
  Size: 8347045    FileType: Regular File
  Mode: (0777/-rwxrwxrwx)         Uid: (1001450/(1001450))  Gid: (1000069/(1000069))
Device: 136,1757282482   Inode: 4314169351    Links: 3
Access: Wed Jun 14 13:56:49 2023    <-- Access Time is newer than Target Access Time
Modify: Sun Jun 11 09:08:41 2023
Change: Sun Jun 11 09:08:41 2023


Target:
SIQ-2# stat -x /ifs/data/Sync_Test1
  File: "/ifs/data/Sync_Test1"
  Size: 8347045      FileType: Regular File
  Mode: (0777/-rwxrwxrwx)         Uid: (1000759/(1000759))  Gid: (1000195/(1000195))
Device: 18446744073709551597,18446744072263041268   Inode: 51447964289    Links: 3
Access: Sun Jun 11 09:08:35 2023   <-- Target Access time is not updated
Modify: Sun Jun 11 09:08:41 2023
Change: Sun Jun 11 10:21:48 2023

Cause

SyncIQ baserer all endringsoverføring på attributter som er synlige i et øyeblikksbilde. SyncIQ kan bare overføre en gang fra kilde til mål. Når en kildefil har hatt en annen modifikasjon som utløser en COW, for eksempel en tillatelsesendring.

Resolution

Dette er tiltenkt, en forespørsel om funksjonsforbedring er sendt inn for fremtidig kode.