PowerScale: Linux CEE-fejlfinding og logindsamling
Summary: Sådan aktiverer du fejlfinding i Common Event Enabler (CEE) på en Linux CEE-boks.
This article applies to
This article does not apply to
This article is not tied to any specific product.
Not all product versions are identified in this article.
Instructions
Mens du kører en Linux CEE, kan fejlfindingstilstand aktiveres for at indsamle mere avancerede data til fejlfinding, følg nedenstående trin:
Kopiér konfigurationsfilen for at gøre det nemt at gendanne:
#cp /opt/CEEPack/emc_cee_config.xml /opt/CEEPack/emc_cee_config.xml.bak Edit the /opt/CEEPack/emc_cee_config.xml configuration file to set both debug and Verbose to 63.
#vi /opt/CEEPack/emc_cee_config.xml Under Configuration, find "Debug" and "Verbose" and change value to 63:
<Configuration>
<CacheSize>100</CacheSize>
<Debug>63</Debug>
<HeartBeatIntervalSecs>10</HeartBeatIntervalSecs>
<InstrIntervalSecs>60</InstrIntervalSecs>
<NumberOfThreads>20</NumberOfThreads>
<Verbose>63</Verbose>
<HttpPort>12228</HttpPort>
<DirDBPath></DirDBPath>
<WatchDog>
<RestartDelay>5</RestartDelay>
<RestartCount>2</RestartCount>
<ResetRestartCountAfter>86400</ResetRestartCountAfter>
</WatchDog>
</Configuration>
</CEEConfig>
Restart the CEE process:
# /opt/CEEPack/emc_cee_svc restart Shutting down EMC CEE Service: [ OK ] Starting EMC CEE Service: emc_cee.exe (pid 18902 18899) is running... Debug is now enabled. Trigger some auditable events on the cluster or monitor for the error we are troubleshooting then revert back to original. To revert back to original config: First, I like to make a copy of the debug config for future use:
#cp /opt/CEEPack/emc_cee_config.xml /opt/CEEPack/emc_cee_config.xml.debug Then Copy the original backup back to the main config and restart CEE again
#cp /opt/CEEPack/emc_cee_config.xml.bak /opt/CEEPack/emc_cee_config.xml #/opt/CEEPack/emc_cee_svc restart We want to then gather the log file /opt/CEEPack/emc_cee_svc.log and have that sent in for review.
Additional Information
For CEE på Linux-konfigurations- og brugsinstruktioner skal du følge dokumentationen "Common Event Enabler on Linux", der er vedhæftet.
Hvis der blev lavet en tidligere lavet fejlfindingskopi af konfigurationsfilen, og den oprindelige konfiguration stadig findes, kan fejlfindingsfilen kopieres til hovedkonfigurationen og genstarte tjenesten (sikkerhedskopier altid den aktuelle konfiguration som vist ovenfor):
#cp /opt/CEEPack/emc_cee_config.xml.debug /opt/CEEPack/emc_cee_config.xml #/opt/CEEPack/emc_cee_svc restart
Affected Products
PowerScale OneFSProducts
PowerScale OneFSArticle Properties
Article Number: 000009293
Article Type: How To
Last Modified: 20 Nov 2025
Version: 4
Find answers to your questions from other Dell users
Support Services
Check if your device is covered by Support Services.