Symptoms

在使用客户提供的 vCenter 和共享 Witness 部署 vSAN 双节点群集时,部署失败并显示错误“无法将标准群集转换为延伸群集 LAG-NAM”。

 

检查 VxRail Manager /var/log/microservice_log/dayone.log,是否存在关于“无法满足共享见证的功能要求”的 vim.fault.VsanFault。

2022-05-05-14:01:57 microservice.do-cluster "[2022-05-05 14:01:57,066: WARNING/MainProcess] pyVmomi.VmomiSupport.vim.fault.VsanFault: (vim.fault.VsanFault) {"
2022-05-05-14:01:57 microservice.do-cluster "   dynamicType = <unset>,"
2022-05-05-14:01:57 microservice.do-cluster "   dynamicProperty = (vmodl.DynamicProperty) [],"
2022-05-05-14:01:57 microservice.do-cluster "   msg = 'cannot meet the capability requirement of shared witness.'"

Cause

ESXi 节点版本与共享见证 vSAN 磁盘格式版本不兼容。

Resolution

1.通过以下方式检查共享见证的 vSAN 磁盘格式版本: vSphere Web Client:[vSAN 群集] >配置 > vSAN > 磁盘管理。
image.png
选择共享见证 > 查看磁盘。
image.png
 

2.检查 vSAN 磁盘格式版本支持矩阵 ,以确定哪个 ESXi 版本与共享见证 vSAN 磁盘格式版本兼容。
 

3.如果 ESXi 节点不支持共享见证的 vSAN 磁盘格式版本,则有两个选项可解决此问题:

选项 1.升级 ESXi 节点版本以支持共享见证 vSAN 磁盘格式。

联系戴尔支持工程师,以使用“快速设备自我恢复 (RASR) 出厂映像升级过程”升级 ESXi 节点

然后使用新代码版本部署 vSAN 双节点群集。


选项 2.使用独立见证部署 vSAN 双节点群集。