AppSync: VMware Sanal NVMe Denetleyicilerinde VMWare Sanal Diskler için uygulama eşlemesi başarısız oluyor

Summary: AppSync, VMWare NVMe Sanal Denetleyicilerini desteklemez.

This article applies to This article does not apply to This article is not tied to any specific product. Not all product versions are identified in this article.

Symptoms

Uygulama eşleme aşaması java.lang.StringIndexOutOfBoundsException ile başarısız oldu:  AppSync Sunucusu günlüğünde görüldüğü üzere dize dizini aralık dışında.

CSV Etkinliği şunları gösterecektir:

 

2019-02-17 19:48:20.161,Uygulama eşleme, SPP_000001,AppSyncServer,UYGULAMA için
uygulama eşleme aşaması 2019-02-17 19:48:29.688,Uygulama eşleme, MILE_000005,AppSyncServer,UYGULAMA için uygulama eşleme aşaması hatalarla tamamlandı

 
 
AppSync Sunucu Günlüğü:
 

02-17-2019 19:48:27.501 ERROR WFLYEJB0034: EJB Invocation failed on component MapGenericStorageCommandBean for method public void com.emc.archway.commands.genericstorage.MapGenericStorageCommandBean.mapNew(com.emc.archway.context.ExecutionContext,com.emc.archway.objectmodel.serviceplan.PhasePit,java.util.Collection) throws com.emc.archway.errorMessages.ArchwayException: javax.ejb.EJBException: java.lang.StringIndexOutOfBoundsException: String index out of range: -40

02-17-2019 19:48:27.845 DEBUG >>> Finding physicaldisks associated with HostFileSystemEntity: E:\

02-17-2019 19:48:27.845 ERROR WFLYEJB0034: EJB Invocation failed on component GetSourceStorageCommandBean for method public java.util.List ... throws com.emc.archway.errorMessages.UnsupportedOperationException: javax.ejb.EJBTransactionRolledbackException: String index out of range: -40
Neden: java.lang.StringIndexOutOfBoundsException: String index out of range: -40


02-17-2019 19:48:28.485 ERROR Exception Occurred: StringIndexOutOfBoundsException, Message: String index out of range: -40


 
 Aracı günlüklerinden, fiziksel sürücülerin WWN'si beklenen değer olarak 32 karakter yerine 72 karakter olarak geliyor ve bu da aralık dışı/bağlı özel durumu tetikliyor.
 
AppSync Aracı Günlükleri:

 

2019-02-17 19:48:23.201 INFO [6580] [] [XXXXXXXXX] [f5f10af6-18eb-47f2-aa9c-ab57e7c82e91] Device Properties
2019-02-17 19:48:23.201 INFO [6580] [] [XXXXXXXXX] [f5f10af6-18eb-47f2-aa9c-ab57e7c82e91] -----------------
2019-02-17 19:48:23.201 INFO [6580] [] [XXXXXXXXX] [f5f10af6-18eb-47f2-aa9c-ab57e7c82e91] Cihaz Türü : (0x0)
2019-02-17 19:48:23.201 INFO [6580] [] [XXXXXXXXX] [f5f10af6-18eb-47f2-aa9c-ab57e7c82e91] Removable Media : Hayır
2019-02-17 19:48:23.201 INFO [6580] [] [XXXXXXXXX] [f5f10af6-18eb-47f2-aa9c-ab57e7c82e91] Vendor ID : VMware (VMware Teknolojisi
2019-02-17 19:48:23.201 INFO [6580] [] [XXXXXXXXX] [f5f10af6-18eb-47f2-aa9c-ab57e7c82e91] Ürün Kimliği : Sanal disk
2019-02-17 19:48:23.201 INFO [6580] [] [XXXXXXXXX] [f5f10af6-18eb-47f2-aa9c-ab57e7c82e91] Product Revision: 2.0
2019-02-17 19:48:23.201 INFO [6580] [] [XXXXXXXXX] [f5f10af6-18eb-47f2-aa9c-ab57e7c82e91] Serial Number : 6000c292XXXXXXXXXXXXXXX
2019-02-17 19:48:23.201 INFO [6580] [] [XXXXXXXXX] [f5f10af6-18eb-47f2-aa9c-ab57e7c82e91] PHYSICALDRIVE : 
.*PHYSICALDRIVEXX*
2019-02-17 19:48:23.201 INFO [6580] [] [XXXXXXXXX] [f5f10af6-18eb-47f2-aa9c-ab57e7c82e91] RMInquiry::InquireDrive - Inquire drive completed for : \\.\PHYSICALDRIVEXX
2019-02-17 19:48:23.201 INFO [6580] [] [XXXXXXXXX] [f5f10af6-18eb-47f2-aa9c-ab57e7c82e91] Number of Page 83 idenfitiers:
12019-02-17 19:48:23.201 INFO [6580] [] [XXXXXXXXX] [f5f10af6-18eb-47f2-aa9c-ab57e7c82e91] Sayfa 83 tanımlayıcı dizini 0, id=8 size=36
2019-02-17 19:48:23.201 INFO [6580] [] [XXXXXXXXX] [f5f10af6-18eb-47f2-aa9c-ab57e7c82e91] Page 83 SCSI name string found
2019-02-17 19:48:23.201 INFO [6580] [] [XXXXXXXXX] [f5f10af6-18eb-47f2-aa9c-ab57e7c82e91] Device WWN: 566972747561XXXXXX69736B00000000303030305F303030305F303030305F3030XXXXXX

 

Cause

Sanal diskler, Kaynak ana bilgisayar düzenleme ayarlarında görüldüğü gibi bir VMware NVMe Denetleyicisine tanımlanır.
AppSync, VMWare NVMe Denetleyicilerini desteklemez.

Resolution

AppSync, Vmware NVMe aygıtlarını desteklemez.
AppSync Destek Matrisinde açıklandığı gibi AppSync tarafından desteklenen bir VMWare Denetleyicisi kullanın.
5 Mart 2019 itibarıyla AppSync Destek Matrisi şunları belirtir:

 
RDM ve Vdisk için yalnızca BusLogic Parallel, LSI Logic ve VMware Paravirtual SCSI denetleyicileri desteklenir.

Additional Information

Bu makalede, Kaynak ana bilgisayarın düzenleme ayarlarında görüldüğü üzere, bir VMware NVMe Denetleyicisine tanımlanan VMware sanal diskinde bulunan ve korunmakta olan bir SQL Server veri tabanına sahip olan eşleme hatasıyla ilgili bu sorun açıklanmaktadır.

Kaynak ana bilgisayardan alınan emcreports'taki çıktıda görüldüğü gibi normal bir inq, bir NVMe Denetleyicisinin kullanılıp kullanılmadığını belirlemek için şu şekilde kullanılabilir:
 

Sorgulama yardımcı programı, Sürüm V9.0-2503 (Rev 0.0)
(c) 2018 Telif Hakkı Dell Inc. Tüm Hakları Saklıdır.
Yardım için inq -h yazın.



...................------------------------------------------------------------------------------
DEVICE :VEND :P ROD :REV :SER NUM :CAP(kb)
------------------------------------------------------------------------------
\\.\PHYSICALDRIVE0 :NVMe :Virtual disk :1.0 :           :  3351248896
\\.\PHYSICALDRIVE1 :NVMe :Sanal disk :1.0 :           :  1073741824
\\.\PHYSICALDRIVE2 :NVMe :Virtual disk :1.0 :           : 16106127360
\\.\PHYSICALDRIVE3 :NVMe :Sanal disk :1.0 :           :  3351248896