Nestabilita procesu PowerFlex SDS způsobuje chybu I/O
Summary: Systém SDS opakovaně nereaguje, což způsobuje chyby I/O, protože není evakuován ze systému.
This article applies to
This article does not apply to
This article is not tied to any specific product.
Not all product versions are identified in this article.
Symptoms
V událostech MDM může být pozorováno opakované odpojení SDS (opakované odpojení) s případnou aplikací a SDC hlásícími chyby I/O. Nestabilita SDS je pozorována u událostí MDM:
# grep ee9b4eb200000002 events.txt | egrep -v "(OSC|SDC_CON|SDC_DISC)" 4284507 2020-10-26 23:38:02.330 SDS_RECONNECTED INFO SDS: sds-********v004 (ID ee9b4eb200000002) reconnected 4284546 2020-10-26 23:38:17.103 SDS_RECONNECTED INFO SDS: sds-********v004 (ID ee9b4eb200000002) reconnected 4284674 2020-10-26 23:40:12.318 SDS_RECONNECTED INFO SDS: sds-********v004 (ID ee9b4eb200000002) reconnected
SDC se odpojí od SDS, například od systému ESXi:
vmkernel.0:2020-10-27T04:01:01.193Z cpu56:66319)WARNING: [14896504445] Disconnected from SDS with ID ee9b4eb200000002 vmkernel.0:2020-10-27T04:01:02.296Z cpu32:66320)WARNING: [14896505547] Connected to SDS with ID ee9b4eb200000002 vmkernel.0:2020-10-27T04:01:18.232Z cpu35:66319)WARNING: [14896521482] Disconnected from SDS with ID ee9b4eb200000002 vmkernel.0:2020-10-27T04:01:19.332Z cpu35:66319)WARNING: [14896522582] Connected to SDS with ID ee9b4eb200000002 vmkernel.0:2020-10-27T04:01:34.769Z cpu53:66320)WARNING: [14896538017] Disconnected from SDS with ID ee9b4eb200000002
Na SDC se zobrazí chyba I/O:
2020-10-27T03:38:02.752Z cpu32:66313)WARNING: ScaleIO mapVolIO_ReportIOErrorIfNeeded:491 :[14895126141] IO-ERROR Type TEST_AND_SET. comb: 55880098015. offsetInComb 2721096. SizeInLB 1. SDS_ID 0. Comb Gen 4619. Head Gen 4b30. StartLB ad48. 2020-10-27T03:38:02.752Z cpu32:66313)WARNING: ScaleIO mapVolIO_ReportIOErrorIfNeeded:512 :Vol ID 0x735105ff0000001c. Last vol network error status NOT_CONN(4) Reason (ABORTED) RC (ABORTED) Retry count (5) chan (0) . . . 2020-10-27T04:08:20.234Z cpu35:66313)WARNING: ScaleIO netCon_IsKaNeeded:3761 :CON 0x439dc29f6700 didn't receive message for 30 iterations. Marking as down 2020-10-27T04:08:20.234Z cpu18:66894)WARNING: ScaleIO netSock_RcvIntrn:1920 :Error: Failed to receive 128 data PTR 0x439dc29f5efc socket 0x439dc29f6418 2020-10-27T04:08:20.234Z cpu33:66806)WARNING: ScaleIO netSock_RcvIntrn:1920 :Error: Failed to receive 128 data PTR 0x439dc29f817c socket 0x439dc29f8698 2020-10-27T04:08:20.234Z cpu0:66879)WARNING: ScaleIO netSock_RcvIntrn:1920 :Error: Failed to receive 128 data PTR 0x439dc29f6a7c socket 0x439dc29f6f98 2020-10-27T04:08:20.234Z cpu23:66319)WARNING: [14896943442] Disconnected from SDS with ID ee9b4eb200000002 2020-10-27T04:08:23.246Z cpu37:65868)Res6: 2346: All helpers quiesced (12 cancelled) for vol 'SD4W21AVxFlexCU03': 1280 LFBCs, 20/1 buckets allocated (4 KB), 1 flush, 0 helpers
Pokud dochází k opakovanému odpojování a opětovnému připojování SDS, pravděpodobně se jedná o problém popsaný v článku znalostní databáze. V níže uvedeném příkladu vede hardwarový (hardwarový) problém NVDIMM k chybě SIGBUS (špatný přístup k paměti) a způsobuje selhání SDS se signálem 7. Rozšíření 0:
26/10 23:37:55.305617 Termination due to signal 7. PID 2601 Faulting address 0x7efb85004000. errno 0 26/10 23:37:55.306321 Writing backtraces for all UMTs: 26/10 23:38:10.132585 Termination due to signal 7. PID 99889 Faulting address 0x7f5485004000. errno 0 26/10 23:38:10.133167 Writing backtraces for all UMTs:
Messages:
Oct 26 23:37:55 kernel: mce: Uncorrected hardware memory error in user-access at 3d84e04440 Oct 26 23:37:55 kernel: MCE 0x3d84e04: Killing sds-3.0.1000.20:2601 due to hardware memory corruption Oct 26 23:37:55 kernel: MCE 0x3d84e04: dax page page recovery: Recovered Oct 26 23:37:55 kernel: sds-3.0.1000.20:4006 conflicting memory types 3d84e04000-3d84e05000 uncached-minus<->write-back Oct 26 23:37:55 kernel: reserve_memtype failed [mem 0x3d84e04000-0x3d84e04fff], track uncached-minus, req uncached-minus Oct 26 23:37:55 kernel: Could not invalidate pfn=0x3d84e04 from 1:1 map Oct 26 23:37:56 sh: abrt-dump-oops: Found oopses: 1 Oct 26 23:37:56 sh: abrt-dump-oops: Creating problem directories Oct 26 23:37:56 sh: abrt-dump-oops: Not going to make dump directories world readable because PrivateReports is on Oct 26 23:37:56 systemd: Configuration file /opt/nsr/admin/networker.service is marked executable.
Cause
- Selhání softwaru (SW) nebo hardwaru způsobí, že proces SDS přestane reagovat a odpojí se od MDM.
- SDS se zotaví z havárie a projde fází rekonfigurace, která označí tento SDS jako obecně dostupný z pohledu MDM i pro všechny ostatní součásti systému, včetně SDC.
- Po 15 sekundách se SDC znovu pokusí o I/O (výchozí), zatímco SDS opět nereaguje, jak je popsáno v bodě "1".
- Po vypršení časového limitu se I/O nezdaří a aplikace SDC hlásí chybu I/O.
- Kroky "2"→"4" se mohou opakovat, dokud nebude tento bezpečnostní list evakuován ze systému.
Resolution
Systém funguje standardním způsobem.
Možnost 1:
Odeberte SDS z clusteru. Disk SDS můžete kdykoli bez prostojů odebrat. Během odstraňování se přidružená data replikují do různých uzlů. Proces odebrání je asynchronní a může trvat dlouhou dobu.
Opravte problémy s hardwarem a softwarem, které způsobovaly nestabilitu SDS, a vraťte SDS do clusteru.
Možnost 2:
Sledujte systém, a pokud se za podobných okolností začne ozývat funkce SDS, zastavte službu SDS spuštěním následujícího příkazu:
Poznámka: Zastavení služby SDS spustí opětovné vytvoření. Po vyřešení problému restartujte službu SDS spuštěním následujícího příkazu:
Možnost 1:
Odeberte SDS z clusteru. Disk SDS můžete kdykoli bez prostojů odebrat. Během odstraňování se přidružená data replikují do různých uzlů. Proces odebrání je asynchronní a může trvat dlouhou dobu.
Poznámka: Pokud svazky využívají kapacitu tohoto disku SDS a kapacitu nelze nahradit kvůli nedostatku dostupného volného místa, odebrání se nezdaří.
Opravte problémy s hardwarem a softwarem, které způsobovaly nestabilitu SDS, a vraťte SDS do clusteru.
Možnost 2:
Sledujte systém, a pokud se za podobných okolností začne ozývat funkce SDS, zastavte službu SDS spuštěním následujícího příkazu:
/opt/emc/scaleio/sds/bin/delete_service.sh
Poznámka: Zastavení služby SDS spustí opětovné vytvoření. Po vyřešení problému restartujte službu SDS spuštěním následujícího příkazu:
/opt/emc/scaleio/sds/bin/create_service.sh
Additional Information
Odolnost vůči tomuto typu událostí je plánována pro software PowerFlex verze 4.0.
Affected Products
PowerFlex rack, VxRackArticle Properties
Article Number: 000181511
Article Type: Solution
Last Modified: 07 May 2026
Version: 3