L'instabilità del processo dell'SDS PowerFlex causa errore di I/O
Summary: L SDS smette ripetutamente di rispondere, causando errori di I/O perché l SDS non viene evacuato dal sistema.
This article applies to
This article does not apply to
This article is not tied to any specific product.
Not all product versions are identified in this article.
Symptoms
Negli eventi MDM, è possibile osservare ripetute disconnessioni dell SDS (disaccoppiamento ripetuto) con possibili errori di I/O dell'applicazione e dell SDC. L'instabilità SDS viene osservata negli eventi MDM:
# grep ee9b4eb200000002 events.txt | egrep -v "(OSC|SDC_CON|SDC_DISC)" 4284507 2020-10-26 23:38:02.330 SDS_RECONNECTED INFO SDS: sds-********v004 (ID ee9b4eb200000002) reconnected 4284546 2020-10-26 23:38:17.103 SDS_RECONNECTED INFO SDS: sds-********v004 (ID ee9b4eb200000002) reconnected 4284674 2020-10-26 23:40:12.318 SDS_RECONNECTED INFO SDS: sds-********v004 (ID ee9b4eb200000002) reconnected
L SDC si disconnette dall SDS, ad esempio da ESXi:
vmkernel.0:2020-10-27T04:01:01.193Z cpu56:66319)WARNING: [14896504445] Disconnected from SDS with ID ee9b4eb200000002 vmkernel.0:2020-10-27T04:01:02.296Z cpu32:66320)WARNING: [14896505547] Connected to SDS with ID ee9b4eb200000002 vmkernel.0:2020-10-27T04:01:18.232Z cpu35:66319)WARNING: [14896521482] Disconnected from SDS with ID ee9b4eb200000002 vmkernel.0:2020-10-27T04:01:19.332Z cpu35:66319)WARNING: [14896522582] Connected to SDS with ID ee9b4eb200000002 vmkernel.0:2020-10-27T04:01:34.769Z cpu53:66320)WARNING: [14896538017] Disconnected from SDS with ID ee9b4eb200000002
Sull SDC viene visualizzato un errore di I/O:
2020-10-27T03:38:02.752Z cpu32:66313)WARNING: ScaleIO mapVolIO_ReportIOErrorIfNeeded:491 :[14895126141] IO-ERROR Type TEST_AND_SET. comb: 55880098015. offsetInComb 2721096. SizeInLB 1. SDS_ID 0. Comb Gen 4619. Head Gen 4b30. StartLB ad48. 2020-10-27T03:38:02.752Z cpu32:66313)WARNING: ScaleIO mapVolIO_ReportIOErrorIfNeeded:512 :Vol ID 0x735105ff0000001c. Last vol network error status NOT_CONN(4) Reason (ABORTED) RC (ABORTED) Retry count (5) chan (0) . . . 2020-10-27T04:08:20.234Z cpu35:66313)WARNING: ScaleIO netCon_IsKaNeeded:3761 :CON 0x439dc29f6700 didn't receive message for 30 iterations. Marking as down 2020-10-27T04:08:20.234Z cpu18:66894)WARNING: ScaleIO netSock_RcvIntrn:1920 :Error: Failed to receive 128 data PTR 0x439dc29f5efc socket 0x439dc29f6418 2020-10-27T04:08:20.234Z cpu33:66806)WARNING: ScaleIO netSock_RcvIntrn:1920 :Error: Failed to receive 128 data PTR 0x439dc29f817c socket 0x439dc29f8698 2020-10-27T04:08:20.234Z cpu0:66879)WARNING: ScaleIO netSock_RcvIntrn:1920 :Error: Failed to receive 128 data PTR 0x439dc29f6a7c socket 0x439dc29f6f98 2020-10-27T04:08:20.234Z cpu23:66319)WARNING: [14896943442] Disconnected from SDS with ID ee9b4eb200000002 2020-10-27T04:08:23.246Z cpu37:65868)Res6: 2346: All helpers quiesced (12 cancelled) for vol 'SD4W21AVxFlexCU03': 1280 LFBCs, 20/1 buckets allocated (4 KB), 1 flush, 0 helpers
Se si verificano ripetute disconnessioni e riconnessioni dell SDS, è probabile che si verifichi il problema descritto nell'articolo della KB. Nell'esempio riportato di seguito, un problema hardware (HW) NVDIMM genera un errore SIGBUS (accesso alla memoria errato) e provoca un arresto anomalo dell SDS con segnale 7. Esp.0:
26/10 23:37:55.305617 Termination due to signal 7. PID 2601 Faulting address 0x7efb85004000. errno 0 26/10 23:37:55.306321 Writing backtraces for all UMTs: 26/10 23:38:10.132585 Termination due to signal 7. PID 99889 Faulting address 0x7f5485004000. errno 0 26/10 23:38:10.133167 Writing backtraces for all UMTs:
Messages:
Oct 26 23:37:55 kernel: mce: Uncorrected hardware memory error in user-access at 3d84e04440 Oct 26 23:37:55 kernel: MCE 0x3d84e04: Killing sds-3.0.1000.20:2601 due to hardware memory corruption Oct 26 23:37:55 kernel: MCE 0x3d84e04: dax page page recovery: Recovered Oct 26 23:37:55 kernel: sds-3.0.1000.20:4006 conflicting memory types 3d84e04000-3d84e05000 uncached-minus<->write-back Oct 26 23:37:55 kernel: reserve_memtype failed [mem 0x3d84e04000-0x3d84e04fff], track uncached-minus, req uncached-minus Oct 26 23:37:55 kernel: Could not invalidate pfn=0x3d84e04 from 1:1 map Oct 26 23:37:56 sh: abrt-dump-oops: Found oopses: 1 Oct 26 23:37:56 sh: abrt-dump-oops: Creating problem directories Oct 26 23:37:56 sh: abrt-dump-oops: Not going to make dump directories world readable because PrivateReports is on Oct 26 23:37:56 systemd: Configuration file /opt/nsr/admin/networker.service is marked executable.
Cause
- Il guasto del software (software) o dell'hardware fa sì che il processo SDS non risponda e si disconnetta da MDM.
- L SDS si ripristina in seguito all'arresto anomalo e supera la "fase di riconfigurazione" che contrassegna questo SDS come generalmente disponibile dal punto di vista dell MDM e per tutti gli altri componenti del sistema, incluso l SDC.
- Dopo 15 secondi, l SDC effettua un nuovo tentativo di I/O (impostazione predefinita), mentre l SDS non risponde più come descritto nel punto "1".
- L'I/O non riesce al timeout e l'applicazione SDC segnala un errore di I/O.
- I passaggi "2"→"4" possono ripetersi più volte fino a quando l SDS non viene evacuato dal sistema.
Resolution
Il sistema funziona come previsto.
Opzione 1:
Rimuovere l SDS dal cluster. È possibile rimuovere un SDS in qualsiasi momento, senza downtime. Durante la rimozione, i dati associati vengono replicati in nodi diversi. Il processo di rimozione è asincrono e può richiedere molto tempo.
Risolvere i problemi hardware e software che causavano l'instabilità dell SDS e riportare l SDS al cluster.
Opzione 2:
Monitorare il sistema e, se l SDS inizia a instabilità in circostanze simili, arrestare il servizio SDS eseguendo il seguente comando sull SDS:
Nota: L'arresto del servizio SDS attiva una ricostruzione. Una volta risolto il problema, riavviare il servizio SDS eseguendo il seguente comando sull SDS:
Opzione 1:
Rimuovere l SDS dal cluster. È possibile rimuovere un SDS in qualsiasi momento, senza downtime. Durante la rimozione, i dati associati vengono replicati in nodi diversi. Il processo di rimozione è asincrono e può richiedere molto tempo.
Nota: Se i volumi utilizzano la capacità di questo SDS e la capacità non può essere sostituita a causa della mancanza di spazio libero disponibile, la rimozione non riesce.
Risolvere i problemi hardware e software che causavano l'instabilità dell SDS e riportare l SDS al cluster.
Opzione 2:
Monitorare il sistema e, se l SDS inizia a instabilità in circostanze simili, arrestare il servizio SDS eseguendo il seguente comando sull SDS:
/opt/emc/scaleio/sds/bin/delete_service.sh
Nota: L'arresto del servizio SDS attiva una ricostruzione. Una volta risolto il problema, riavviare il servizio SDS eseguendo il seguente comando sull SDS:
/opt/emc/scaleio/sds/bin/create_service.sh
Additional Information
La resilienza a questo tipo di eventi è pianificata per la versione 4.0 del software PowerFlex.