Instabilitet i PowerFlex SDS-prosessen fører til I/O-feil
Summary: SDS svarer gjentatte ganger og forårsaker I/O-feil fordi SDS ikke evakueres fra systemet.
This article applies to
This article does not apply to
This article is not tied to any specific product.
Not all product versions are identified in this article.
Symptoms
I MDM-hendelser kan gjentatt SDS-frakobling (gjentatt frakobling) observeres med mulige I/O-feil for applikasjons- og SDC-rapportering. SDS-ustabilitet observeres i MDM-hendelsene:
# grep ee9b4eb200000002 events.txt | egrep -v "(OSC|SDC_CON|SDC_DISC)" 4284507 2020-10-26 23:38:02.330 SDS_RECONNECTED INFO SDS: sds-********v004 (ID ee9b4eb200000002) reconnected 4284546 2020-10-26 23:38:17.103 SDS_RECONNECTED INFO SDS: sds-********v004 (ID ee9b4eb200000002) reconnected 4284674 2020-10-26 23:40:12.318 SDS_RECONNECTED INFO SDS: sds-********v004 (ID ee9b4eb200000002) reconnected
SDC kobles fra SDS, for eksempel fra ESXi:
vmkernel.0:2020-10-27T04:01:01.193Z cpu56:66319)WARNING: [14896504445] Disconnected from SDS with ID ee9b4eb200000002 vmkernel.0:2020-10-27T04:01:02.296Z cpu32:66320)WARNING: [14896505547] Connected to SDS with ID ee9b4eb200000002 vmkernel.0:2020-10-27T04:01:18.232Z cpu35:66319)WARNING: [14896521482] Disconnected from SDS with ID ee9b4eb200000002 vmkernel.0:2020-10-27T04:01:19.332Z cpu35:66319)WARNING: [14896522582] Connected to SDS with ID ee9b4eb200000002 vmkernel.0:2020-10-27T04:01:34.769Z cpu53:66320)WARNING: [14896538017] Disconnected from SDS with ID ee9b4eb200000002
I/O-feil vises på SDC:
2020-10-27T03:38:02.752Z cpu32:66313)WARNING: ScaleIO mapVolIO_ReportIOErrorIfNeeded:491 :[14895126141] IO-ERROR Type TEST_AND_SET. comb: 55880098015. offsetInComb 2721096. SizeInLB 1. SDS_ID 0. Comb Gen 4619. Head Gen 4b30. StartLB ad48. 2020-10-27T03:38:02.752Z cpu32:66313)WARNING: ScaleIO mapVolIO_ReportIOErrorIfNeeded:512 :Vol ID 0x735105ff0000001c. Last vol network error status NOT_CONN(4) Reason (ABORTED) RC (ABORTED) Retry count (5) chan (0) . . . 2020-10-27T04:08:20.234Z cpu35:66313)WARNING: ScaleIO netCon_IsKaNeeded:3761 :CON 0x439dc29f6700 didn't receive message for 30 iterations. Marking as down 2020-10-27T04:08:20.234Z cpu18:66894)WARNING: ScaleIO netSock_RcvIntrn:1920 :Error: Failed to receive 128 data PTR 0x439dc29f5efc socket 0x439dc29f6418 2020-10-27T04:08:20.234Z cpu33:66806)WARNING: ScaleIO netSock_RcvIntrn:1920 :Error: Failed to receive 128 data PTR 0x439dc29f817c socket 0x439dc29f8698 2020-10-27T04:08:20.234Z cpu0:66879)WARNING: ScaleIO netSock_RcvIntrn:1920 :Error: Failed to receive 128 data PTR 0x439dc29f6a7c socket 0x439dc29f6f98 2020-10-27T04:08:20.234Z cpu23:66319)WARNING: [14896943442] Disconnected from SDS with ID ee9b4eb200000002 2020-10-27T04:08:23.246Z cpu37:65868)Res6: 2346: All helpers quiesced (12 cancelled) for vol 'SD4W21AVxFlexCU03': 1280 LFBCs, 20/1 buckets allocated (4 KB), 1 flush, 0 helpers
Hvis det oppstår gjentatte SDS-frakoblinger og nye tilkoblinger, oppstår problemet som er beskrevet i KB. I eksemplet nedenfor fører et NVDIMM-maskinvareproblem (HW) til en SIGBUS-feil (dårlig minnetilgang) og forårsaker SDS-krasj med signal 7. exp.0:
26/10 23:37:55.305617 Termination due to signal 7. PID 2601 Faulting address 0x7efb85004000. errno 0 26/10 23:37:55.306321 Writing backtraces for all UMTs: 26/10 23:38:10.132585 Termination due to signal 7. PID 99889 Faulting address 0x7f5485004000. errno 0 26/10 23:38:10.133167 Writing backtraces for all UMTs:
Meldinger:
Oct 26 23:37:55 kernel: mce: Uncorrected hardware memory error in user-access at 3d84e04440 Oct 26 23:37:55 kernel: MCE 0x3d84e04: Killing sds-3.0.1000.20:2601 due to hardware memory corruption Oct 26 23:37:55 kernel: MCE 0x3d84e04: dax page page recovery: Recovered Oct 26 23:37:55 kernel: sds-3.0.1000.20:4006 conflicting memory types 3d84e04000-3d84e05000 uncached-minus<->write-back Oct 26 23:37:55 kernel: reserve_memtype failed [mem 0x3d84e04000-0x3d84e04fff], track uncached-minus, req uncached-minus Oct 26 23:37:55 kernel: Could not invalidate pfn=0x3d84e04 from 1:1 map Oct 26 23:37:56 sh: abrt-dump-oops: Found oopses: 1 Oct 26 23:37:56 sh: abrt-dump-oops: Creating problem directories Oct 26 23:37:56 sh: abrt-dump-oops: Not going to make dump directories world readable because PrivateReports is on Oct 26 23:37:56 systemd: Configuration file /opt/nsr/admin/networker.service is marked executable.
Cause
- Feil på programvare (SW) eller HW fører til at SDS-prosessen ikke svarer og kobles fra MDM.
- SDS kommer seg etter krasjet og passerer "rekonfigureringsstadiet" som markerer dette SDS som generelt tilgjengelig fra MDMs synspunkt, og til alle andre systemkomponenter, inkludert SDC.
- Etter 15 sekunder prøver SDC I/O på nytt (standard), mens SDS ikke svarer igjen som beskrevet i punkt "1".
- I/O mislykkes ved tidsavbrudd, og SDC-applikasjonen rapporterer en I/O-feil.
- Trinn "2"→"4" kan forekomme igjen og igjen til denne SDS evakueres fra systemet.
Resolution
Systemet fungerer som det skal.
Alternativ 1:
Fjern SDS fra klyngen. Du kan fjerne et SDS når som helst, uten at nedetid er nødvendig. Under fjerning replikeres de tilknyttede dataene til forskjellige noder. Fjerningsprosessen er asynkron og kan ta lang tid.
Reparer HW- og programvareproblemene som forårsaket ustabiliteten i SDS, og returner SDS til klyngen.
Alternativ 2:
Overvåk systemet, og hvis SDS begynner å klappe under lignende omstendigheter, stopp SDS-tjenesten ved å kjøre følgende kommando på SDS:
Merk: Hvis du stopper SDS-tjenesten, utløses en gjenoppbygging. Når problemet er løst, starter du SDS-tjenesten på nytt ved å kjøre følgende kommando på SDS:
Alternativ 1:
Fjern SDS fra klyngen. Du kan fjerne et SDS når som helst, uten at nedetid er nødvendig. Under fjerning replikeres de tilknyttede dataene til forskjellige noder. Fjerningsprosessen er asynkron og kan ta lang tid.
Merk: Hvis volumene bruker kapasiteten til dette SDS, og kapasiteten ikke kan erstattes på grunn av mangel på ledig plass, mislykkes fjerningen.
Reparer HW- og programvareproblemene som forårsaket ustabiliteten i SDS, og returner SDS til klyngen.
Alternativ 2:
Overvåk systemet, og hvis SDS begynner å klappe under lignende omstendigheter, stopp SDS-tjenesten ved å kjøre følgende kommando på SDS:
/opt/emc/scaleio/sds/bin/delete_service.sh
Merk: Hvis du stopper SDS-tjenesten, utløses en gjenoppbygging. Når problemet er løst, starter du SDS-tjenesten på nytt ved å kjøre følgende kommando på SDS:
/opt/emc/scaleio/sds/bin/create_service.sh
Additional Information
Fleksibilitet mot denne typen hendelser er planlagt for PowerFlex-programvareversjon 4.0.
Affected Products
PowerFlex rack, VxRackArticle Properties