A instabilidade do processo de SDS do PowerFlex causa erro de E/S

Summary: O SDS fica repetidamente sem responder, causando erros de E/S porque o SDS não é evacuado do sistema.

This article applies to This article does not apply to This article is not tied to any specific product. Not all product versions are identified in this article.

Symptoms

Em eventos de MDM, a desconexão repetida do SDS (desacoplamento repetido) pode ser observada com possíveis erros de E/S de relatório do aplicativo e SDC. A instabilidade do SDS é observada nos eventos do MDM:

# grep ee9b4eb200000002 events.txt  | egrep -v "(OSC|SDC_CON|SDC_DISC)"
4284507 2020-10-26 23:38:02.330 SDS_RECONNECTED           INFO     	 SDS: sds-********v004 (ID ee9b4eb200000002) reconnected 
4284546 2020-10-26 23:38:17.103 SDS_RECONNECTED           INFO     	 SDS: sds-********v004 (ID ee9b4eb200000002) reconnected

4284674 2020-10-26 23:40:12.318 SDS_RECONNECTED           INFO     	 SDS: sds-********v004 (ID ee9b4eb200000002) reconnected

O SDC se desconecta do SDS, por exemplo, do ESXi:

vmkernel.0:2020-10-27T04:01:01.193Z cpu56:66319)WARNING: [14896504445] Disconnected from SDS with ID ee9b4eb200000002
vmkernel.0:2020-10-27T04:01:02.296Z cpu32:66320)WARNING: [14896505547] Connected to SDS with ID ee9b4eb200000002
vmkernel.0:2020-10-27T04:01:18.232Z cpu35:66319)WARNING: [14896521482] Disconnected from SDS with ID ee9b4eb200000002
vmkernel.0:2020-10-27T04:01:19.332Z cpu35:66319)WARNING: [14896522582] Connected to SDS with ID ee9b4eb200000002
vmkernel.0:2020-10-27T04:01:34.769Z cpu53:66320)WARNING: [14896538017] Disconnected from SDS with ID ee9b4eb200000002

O erro de E/S é exibido no SDC:

2020-10-27T03:38:02.752Z cpu32:66313)WARNING: ScaleIO mapVolIO_ReportIOErrorIfNeeded:491 :[14895126141] IO-ERROR Type TEST_AND_SET. comb: 55880098015. offsetInComb 2721096. SizeInLB 1. SDS_ID 0. Comb Gen 4619. Head Gen 4b30. StartLB ad48.
2020-10-27T03:38:02.752Z cpu32:66313)WARNING: ScaleIO mapVolIO_ReportIOErrorIfNeeded:512 :Vol ID 0x735105ff0000001c. Last vol network error status NOT_CONN(4) Reason (ABORTED) RC (ABORTED) Retry count (5) chan (0)
.
.
.
2020-10-27T04:08:20.234Z cpu35:66313)WARNING: ScaleIO netCon_IsKaNeeded:3761 :CON 0x439dc29f6700 didn't receive message for 30 iterations.  Marking as down
2020-10-27T04:08:20.234Z cpu18:66894)WARNING: ScaleIO netSock_RcvIntrn:1920 :Error: Failed  to receive 128 data PTR 0x439dc29f5efc socket 0x439dc29f6418
2020-10-27T04:08:20.234Z cpu33:66806)WARNING: ScaleIO netSock_RcvIntrn:1920 :Error: Failed  to receive 128 data PTR 0x439dc29f817c socket 0x439dc29f8698
2020-10-27T04:08:20.234Z cpu0:66879)WARNING: ScaleIO netSock_RcvIntrn:1920 :Error: Failed  to receive 128 data PTR 0x439dc29f6a7c socket 0x439dc29f6f98
2020-10-27T04:08:20.234Z cpu23:66319)WARNING: [14896943442] Disconnected from SDS with ID ee9b4eb200000002
2020-10-27T04:08:23.246Z cpu37:65868)Res6: 2346: All helpers quiesced (12 cancelled)  for vol 'SD4W21AVxFlexCU03': 1280 LFBCs, 20/1 buckets allocated (4 KB), 1 flush, 0 helpers

Se ocorrerem desconexões e reconexões repetidas do SDS, o problema descrito no artigo da KB provavelmente está ocorrendo. No exemplo abaixo, um problema de hardware do NVDIMM (HW) leva a um erro SIGBUS (acesso incorreto à memória) e causa uma falha do SDS com sinal 7. exp.0:

26/10 23:37:55.305617 Termination due to signal 7. PID 2601 Faulting address 0x7efb85004000. errno 0
26/10 23:37:55.306321 Writing backtraces for all UMTs:
26/10 23:38:10.132585 Termination due to signal 7. PID 99889 Faulting address 0x7f5485004000. errno 0
26/10 23:38:10.133167 Writing backtraces for all UMTs:

Messages:

Oct 26 23:37:55  kernel: mce: Uncorrected hardware memory error in user-access at 3d84e04440
Oct 26 23:37:55  kernel: MCE 0x3d84e04: Killing sds-3.0.1000.20:2601 due to hardware memory corruption
Oct 26 23:37:55  kernel: MCE 0x3d84e04: dax page page recovery: Recovered
Oct 26 23:37:55  kernel: sds-3.0.1000.20:4006 conflicting memory types 3d84e04000-3d84e05000 uncached-minus<->write-back
Oct 26 23:37:55  kernel: reserve_memtype failed [mem 0x3d84e04000-0x3d84e04fff], track uncached-minus, req uncached-minus
Oct 26 23:37:55  kernel: Could not invalidate pfn=0x3d84e04 from 1:1 map
Oct 26 23:37:56  sh: abrt-dump-oops: Found oopses: 1
Oct 26 23:37:56  sh: abrt-dump-oops: Creating problem directories
Oct 26 23:37:56  sh: abrt-dump-oops: Not going to make dump directories world readable because PrivateReports is on
Oct 26 23:37:56  systemd: Configuration file /opt/nsr/admin/networker.service is marked executable.

Cause

  1. A falha de software (SW) ou de hardware faz com que o processo do SDS não responda e se desconecte do MDM.
  2. O SDS se recupera da falha e passa no "estágio de reconfiguração", que marca esse SDS como geralmente disponível do ponto de vista do MDM e para todos os outros componentes do sistema, inclusive o SDC.
  3. Após 15 segundos, o SDC repetirá a E/S (padrão); enquanto isso, o SDS não responde novamente, conforme descrito no ponto "1".
  4. A E/S falha com o tempo de espera excedido, e o aplicativo SDC relata um erro de E/S.
  5. As etapas "2"→"4" podem ocorrer repetidamente até que esse SDS seja evacuado do sistema.

Resolution

O sistema está funcionando conforme projetado.

Opção 1:
Remova o SDS do cluster. Você pode remover um SDS a qualquer momento, sem necessidade de tempo de inatividade. Durante a remoção, os dados associados são replicados para diferentes nós. O processo de remoção é assíncrono e pode levar muito tempo.
 
Nota: Se os volumes usarem a capacidade desse SDS e a capacidade não puder ser substituída devido à falta de espaço livre disponível, a remoção falhará.

Corrija os problemas de hardware e software que causaram a instabilidade do SDS e retorne o SDS ao cluster.

Opção 2:
Monitore o sistema e, se o SDS começar a oscilar em circunstâncias semelhantes, interrompa o serviço SDS executando o seguinte comando no SDS:
 /opt/emc/scaleio/sds/bin/delete_service.sh

Nota: A interrupção do serviço SDS aciona uma recriação. Depois que o problema for resolvido, reinicie o serviço SDS executando o seguinte comando no SDS:
 /opt/emc/scaleio/sds/bin/create_service.sh

Additional Information

A resiliência a esse tipo de evento está planejada para o software PowerFlex versão 4.0.

Affected Products

PowerFlex rack, VxRack
Article Properties
Article Number: 000181511
Article Type: Solution
Last Modified: 07 May 2026
Version:  3
Find answers to your questions from other Dell users
Support Services
Check if your device is covered by Support Services.