Data Domain: STORAGE-00017 Alert | Read Errors Detected on Multiple Disks in the Same Disk Group
Summary: The Data Domain Operating System (DDOS) continuously monitors disk health. When multiple disks within the same disk group report read errors over a one-hour period, DDOS triggers alert STORAGE-00017 and initiates copy reconstructions to protect data integrity. ...
This article applies to
This article does not apply to
This article is not tied to any specific product.
Not all product versions are identified in this article.
Symptoms
The system generates the following alert:
-
Event Id: EVT-STORAGE-00017 Event Message: Read errors have been detected on multiple disks in the same disk group. Event Description: There are too many disks reporting read errors in the same RAID group. As each of these disks completes reconstruction it will be failed. If the ongoing RAID reconstruction fails, there might be permanent loss of data.
System Behavior:
- DDOS initiates copy reconstructions for affected disks.
- Affected disks appear as
(E)Error disks in thedisk show stateoutput. - Other related disk states:
(C)= Copy Rebuild Disk (source disk with errors)(R)= Reconstructing SPARE disk(F)= Failed Disk (copy rebuild completed or pending)
Example Output:
-
sysadmin@DD# disk show state Enclosure Disk Row(disk-id) 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 -------------- ------------------------------------------------- 1 s . . . - - - - - - - . . . . . 2 |--------|--------|--------|--------| |Pack 1|Pack 2|Pack 3|Pack 4| E(49-60) |. . . |. E . |. . . |. . . | D(37-48) |. . . |. C . |. . . |. . . | C(25-36) |. . . |. . F |. . . |. . . | B(13-24) |. . . |. . . |. . . |. . . | A( 1-12) |. . . |F . . |. . . |R . . | |--------|--------|--------|--------| - In this example, we had 4x error disks (E) - 2.53 | 2.41 | 2.30 | 2.4 --> All within the same disk group (Pack 2)
- 2x rebuilds have completed to available SPAREs leaving the faulty disks as 'F' (Failed)
- 1x (C) Copy reconstruction is underway to SPARE (2.10)
- 1x Error Disk (E) will have rebuild 'Pending' until a SPARE is made available.
Cause
DDOS monitors disk SMART and reliability metrics. When more than one disk in the same disk group reports over 20 read errors per hour, DDOS flags STORAGE-00017 and begins copy reconstruction to prevent data loss.
Resolution
Because this alert involves multiple disks in the same disk group, and may impact data integrity, contact Dell Technical Support, or your contracted support provider immediately.
Support will:
- Analyze the event logs.
- Verify the cause of the read errors.
- Confirm that all reconstructions were completed successfully.
- Ensure that data integrity has not been compromised.
Affected Products
Data Domain, PowerProtect Data Protection Appliance, Data Domain Deduplication Storage Systems, Integrated Data Protection Appliance Family, PowerProtect Data Protection HardwareArticle Properties