VNX: server_df comando falha

Summary: VNX: server_df comando falha

This article applies to This article does not apply to This article is not tied to any specific product. Not all product versions are identified in this article.

Symptoms

O comando 'server_df server_2' falha com "Erro 2: server_2 : Nenhum arquivo ou diretório apresentou falha ao concluir o comando":

[nasadmin@ssgnas03cs0 ~]$ server_df server_2
server_2 :
Error 2: server_2 : No such file or directory
failed to complete command

As verificações de integridade pré-upgrade falham com os seguintes erros:

Blades : Check if root filesystem is too large
Error HC_DM_14505148436: Output from command "/nas/bin/server_df
         server_2" has no information on file system root_fs_2

Blades : Check if root filesystem has enough free space
Error HC_DM_14505148440: Output from command "/nas/bin/server_df
         server_2" has no information on file system root_fs_2

Blades : Check if file system usage is under limit
Error HC_DM_14505148563: Could not determine available disk space for
         the mounted file systems on the following Blades:
         * server_2

Todos os outros comandos server_df funcionam com sucesso em outros movimentadores de dados:

[nasadmin@ssgnas03cs0 ~]$ server_df server_3
server_3 :
Filesystem          kbytes         used        avail capacity Mounted on
root_fs_common       15368         5280        10088   34%    /.etc_common
root_fs_3           258128         6184       251944    2%    /

 

Cause

A causa raiz nesse caso foi que o file system raiz do server_2 foi desmontado.

[nasadmin@ssgnas03cs0 ~]$ server_mount ALL
server_2 :
                       <------ nothing mounted
server_3 :
root_fs_3 on / uxfs,perm,rw
root_fs_common on /.etc_common uxfs,perm,ro

Ao listar todos os sistemas de arquivos, ficou claro que o sistema de arquivos raiz "root_fs_2" de server_2 estava listado como não em uso porque foi desmontado.

[nasadmin@ssgnas03cs0 ~]$ nas_fs -l
id      inuse type acl   volume    name                server
1         n    1   0     10        root_fs_1
2         y    1   0     40        root_fs_common      3,2
3         n    5   0     73        root_fs_ufslog
4         n    5   0     76        root_panic_reserve
5         n    5   0     93        root_fs_d3
6         n    5   0     94        root_fs_d4
7         n    5   0     95        root_fs_d5
8         n    5   0     96        root_fs_d6
9         n    1   0     12        root_fs_2              <------------ inuse = n
10        y    1   0     14        root_fs_3           2

 

Resolution

Antes de o cliente solicitar assistência do suporte, uma reinicialização do Data Mover era concluída e nenhuma melhoria era observada. Para resolver esse problema, faça log-in como usuário "root" na Control Station primária e monte novamente o "root_fs_2" do file system no Data Mover server_2:

[root@ssgnas03cs0 nasadmin]# server_mount server_2 root_fs_2 /
server_2 : done

Certifique-se de que o file system raiz seja remontado:

[root@ssgnas03cs0 nasadmin]# server_mount ALL
server_2 :
root_fs_2 on / uxfs,perm,rw
root_fs_common on /.etc_common uxfs,perm,ro

server_3 :
root_fs_3 on / uxfs,perm,rw
root_fs_common on /.etc_common uxfs,perm,ro

Depois que o file system raiz for montado, execute o comando "server_df server_2" para garantir que ele seja concluído com sucesso:

[root@ssgnas03cs0 nasadmin]# server_df server_2
server_2 :
Filesystem          kbytes         used        avail capacity Mounted on
root_fs_common       15368         5280        10088   34%    /.etc_common
root_fs_2           258128         6264       251864    2%    /

 

Additional Information

Nesse caso específico, o cliente estava realizando uma limpeza de file systems desnecessários para recuperar espaço para o pool de NAS. Como parte da limpeza, eles desmontaram permanentemente e tentaram excluir o "root_fs_2" do file system raiz do Data Mover server_2. O file system raiz de um Data Mover nunca deve ser excluído.

 

Affected Products