IDPA: Nástroj PowerProtect DP Rapid Upgrade Checker nahlásil selhání předběžné kontroly upgradu firmwaru

Summary: Zařízení řady PowerProtect Data Protection (DP) a IDPA: Nástroj PowerProtect DP Rapid Upgrade Checker (RUCK) nahlásil selhání kontroly upgradu firmwaru. The cached response with Node Event Service is disabled. Služba událostí uzlu je v degradovaném stavu, servisní modul iDRAC není momentálně dostupný resp. aktivní. Check iDRAC Service Module/iDRAC status. Příčinou může být zastaralý firmware karty NVMe PM1735 ve slotu 4 disku PCIe SSD. ...

This article applies to This article does not apply to This article is not tied to any specific product. Not all product versions are identified in this article.

Symptoms

Nástroj PowerProtect Data Protection Rapid Upgrade Checker (RUCK) selže s následující chybou:

+-----------+--------------------+--------+-----------------------------------------------+-----------------------------------------------+
| Component | Check              | Status | Message                                       | Remedy                                        |
+-----------+--------------------+--------+-----------------------------------------------+-----------------------------------------------+
| ESXi      | firmware_readiness | FAILED | Firmware pre-upgrade checks failed. [ xxx.xxx.| Use KB https://www.dell.com/support/kbdoc/191 |
|           |                    |        | xxx.xxx ]: The cached response with Node Event| 627 to fix the issue.                         |
|           |                    |        | Service is disabled. Node Event Service is in |                                               |
|           |                    |        |  a degraded state,iDRAC Service Module is not |                                               |
|           |                    |        |  available/active at this time. Check iDRAC S |                                               |
|           |                    |        | ervice Module/iDRAC status.                   |                                               |
+-----------+--------------------+--------+-----------------------------------------------+-----------------------------------------------+
[ERROR] Firmware pre-upgrade checks failed. [ <ESXi IP Address> ]: The cached response with Node Event Service is disabled. Node Event Service is in a degraded state, iDRAC Service Module is not available/active at this time. Check iDRAC Service Module/iDRAC status.

Hardwarový model disku PCIe SSD ve slotu 4 je karta Dell Enterprise NVMe AGN MU AIC 1,6 TB (NVMe PM1735) a firmware je nižší než verze 2.3.0.

Model karty SSD PCIe a verzi firmwaru naleznete na stránce iDRAC. > Zařízení PCIe System Physical Disks > – disk PCIe SSD ve slotu 4 Disk 1

V tomto příkladu je karta PCIe SSD PM1725b. Proto se v tomto případě náhradní řešení nepoužije:

Jak najít kartu SSD PCIe z uživatelského rozhraní řadiče iDRAC

Obrázek 1: Jak v uživatelském rozhraní řadiče iDRAC najít kartu PCIe SSD.


V protokolu TSR (Technical Support Report) řadiče Dell iDRAC má karta PCIe SSD název "Dell Ent NVMe AGN MU AIC 1.6TB":

V protokolu TSR má karta NVMe PM1735 název Dell Ent NVMe AGN MU AIC 1,6 TB

Obrázek 2: V protokolu TSR má karta NVMe PM1735 název Dell Ent NVMe AGN MU AIC 1,6 TB.

Modul iDRAC Service Module (iSM) se v uživatelském rozhraní řadiče iDRAC zobrazuje jako Running:

Stav modulu iSM je spuštěn.

Obrázek 3: Stav iSM je spuštěn.

Agent Dell PT a iSM jsou spuštěny a problém přetrvává i po jejich restartování:

[root@ESXi:/opt/dell/DellPTAgent/tools] /etc/init.d/DellPTAgent status
DellPTAgent is running
[root@ESXi:/opt/dell/DellPTAgent/tools] /etc/init.d/DellPTAgent stop
Stopping DellPTAgent...
watchdog-DellPTAgent: Terminating watchdog process with PID 7447869
DellPTAgent stopped
[root@ESXi:/opt/dell/DellPTAgent/tools] /etc/init.d/DellPTAgent start
Starting DellPTAgent...
DellPTAgent started
[root@ESXi:/opt/dell/DellPTAgent/tools] /etc/init.d/DellPTAgent status
DellPTAgent is running
[root@ESXi:/opt/dell/DellPTAgent/tools]

[root@ESXi:/opt/dell/DellPTAgent/tools] /etc/init.d/dcism-netmon-watchdog status
iSM is active (running)
[root@ESXi:/opt/dell/DellPTAgent/tools] /etc/init.d/dcism-netmon-watchdog stop
Module dcism_module successfully unloaded
[root@ESXi:/opt/dell/DellPTAgent/tools] /etc/init.d/dcism-netmon-watchdog start
[root@ESXi:/opt/dell/DellPTAgent/tools] /etc/init.d/dcism-netmon-watchdog status
iSM is active (running)
[root@ESXi:/opt/dell/DellPTAgent/tools]

Cause

Z ACM se ukazuje, že mezipaměť řadiče iDRAC je degradovaná:

ACM:/tmp # dpacli -agentinfo
{"Agent Info": [{"ESXiHost-xxx.xxxx.xxx.xxx": {
    "ptagentversion": "2.4.1-3",
    "uptime": "54 seconds ( 54 seconds )",
    "ism_version": "3.6.0",
    "system_uuid": "618axxxx-xxxx-xxxx-xxxx-xxxxxxxxdd70",
    "process_id": "7440642",
    "host_epoch_time": "1646617738.156490 (secs.usecs)",
    "model": "DP4400",
    "name": "<ESXi_hostname>",
    "mfr": "Dell Inc.",
    "domain": "<ESXi FQDN>",
    "servicetag": "XXXXXXX",
    "os": "VMWare ESXi",
    "os_version": "6.7.0 build-17700523",
    "rest_endpoints": "https://127.0.0.1:8086,https://192.168.100.101:8086",
    "api_blocking_enabled": "false",
    "TPM Present": "false",
    "MarvellLibraryVersion": "5.0.13.1109",
    "libstorelib.so": "07.07",
    "libstorelibir-3.so": "15.03-0",
    "libstorelibit.so": "07.05",
    "idrac_pass_thru_ip": "169.254.0.1",
    "idrac_ethernet_ip": "xx.xxx.xxx.x",
    "host_pass_thru_ip": "169.254.0.2",
    "default_server_cert": "true",
    "status": {
        "idraccache": "Degraded",
        "idracConnection": "OK",
        "iSM": "N/A",
        "agent": "Degraded"
    }
}}]}
ACM:/tmp #

A stejné informace se zobrazují při stahování ze systému ESXi:

[root@ESXi:~] /opt/dell/DellPTAgent/tools/pta_call get agent/info
Request sent to DellPTAgent @ https://192.168.100.101:8086
{
    "TPM Present": "false",
    "MarvellLibraryVersion": "5.0.13.1109",
    "uptime": "344 seconds ( 5 minutes 44 seconds )",
    "system_uuid": "618axxxx-xxxx-xxxx-xxxx-xxxxxxxxdd70",
    "host_pass_thru_ip": "169.254.0.2",
    "servicetag": "XXXXXXX",
    "domain": "<ESXi FQDN>",
    "default_server_cert": "true",
    "libstorelibir-3.so": "15.03-0",
    "model": "DP4400",
    "idrac_ethernet_ip": "xxx.xxx.xxx.xxx",
    "os": "VMWare ESXi",
    "rest_endpoints": "https://127.0.0.1:8086,https://192.168.100.101:8086",
    "mfr": "Dell Inc.",
    "api_blocking_enabled": "false",
    "libstorelib.so": "07.07",
    "ptagentversion": "2.4.1-3",
    "ism_version": "3.6.0",
    "host_epoch_time": "1646618523.10088 (secs.usecs)",
    "os_version": "6.7.0 build-17700523",
    "libstorelibit.so": "07.05",
    "idrac_pass_thru_ip": "169.254.0.1",
    "name": "<ESXi_hostname>",
    "process_id": "7441193",
    "status": {
        "idraccache": "Degraded",
        "idracConnection": "OK",
        "agent": "Degraded",
        "iSM": "N/A"
    }
}
Response: status: 200 [OK], size: 1067 bytes, latency: 0.145 seconds.
[root@ESXi:~]

V tomto případě se agentovi PT nepodařilo vyhledat komponentu "PhysicalDisk" v hwInventory protože má problémy s dotazováním na data z karty NVMe PM1735 ve slotu 4.

V části ESXi /scratch/log/pta_debug.log se zobrazí chybová zpráva:

2022/03/07 04:51:03[UTC] [7459005:193227584] WARN  - WSManClient::isValidResponse: Http request to host: 169.254.0.1, failed with status code: -5
2022/03/07 04:51:03[UTC] [7459005:193227584] WARN  - getComponentFromInventory: Cannot find component 'PhysicalDisk' in hwInventory:
{
    "Message": "Read timed out!",
    "ReturnValue": -5
}
2022/03/07 04:52:57[UTC] [7459005:189000512] WARN  - NvmeDiscoveredDevice::setIntAttrFromDescriptor: Cannot convert string <ie> to int.
2022/03/07 04:52:57[UTC] [7459005:189000512] WARN  - NvmeDiscoveredDevice::setIntAttrFromDescriptor: Failed to read <bay> from <PCIe Slot 4>

Proto doporučujeme provést upgrade firmwaru NVMe 1735 na verzi 2.3.0, která je součástí balení PowerProtect Data Protection Appliance-IDPA Firmware Gen14 December 2021. Požadovaný soubor firmwaru je: Express-Flash-PCIe-SSD_Firmware_RP8RC_WN64_2.3.0_A03.EXE

Resolution

Poznámka: Následující zástupné řešení se vztahuje pouze na zařízení NVMe 1735 s verzí firmwaru nižší než 2.3.0 a NETÝKÁ se modelů NVMe 1725, 1725a a 1725b.


Upgrade firmwaru zařízení NVMe 1735 na verzi 2.3.0:

  1. Stáhněte si soubor "PowerProtect Data Protection Series Appliance-IDPA Firmware Gen14 December 2021" z webu podpory společnosti Dell a poté rozbalte požadovaný soubor firmwaru Express-Flash-PCIe-SSD_Firmware_RP8RC_WN64_2.3.0_A03.EXE.

  2. Vypněte zařízení Integrated Data Protection Appliance z webového uživatelského rozhraní ACM.

  3. Po potvrzení, že je systém ESXi vypnutý, přihlaste se do uživatelského rozhraní řadiče iDRAC a poté ručně nahrajte soubor firmwaru do řadiče iDRAC:
    Jak nahrát firmware v uživatelském rozhraní řadiče iDRAC
    Obrázek 4: Jak nahrát firmware v uživatelském rozhraní řadiče iDRAC

  4. Klikněte na tlačítko Express-Flash-PCIe-SSD_Firmware_RP8RC_WN64_2.3.0_A03.EXE a klikněte na tlačítko Install and Reboot. Poté řadič iDRAC nainstaluje firmware a restartuje se.
    Jak nahrát firmware v uživatelském rozhraní řadiče iDRAC
    Obrázek 5: Jak použít firmware

  5. Po restartování lze ověřit verzi firmwaru v nástroji iDRAC >> System Inventory >Firmware Inventory
    Jak zkontrolovat firmware z inventáře firmwaru
    Obrázek 6: Jak zkontrolovat firmware z inventáře firmwaru

  6. Sledování spuštění DP4400 a úspěšného spuštění všech virtuálních počítačů.
  7. Spusťte dpacli znovu v ACM a potvrďte, že idraccache a stav agenta by se měl změnit na OK:
ACM:~ # dpacli -agentinfo
{"Agent Info": [{"ESXiHost-xxx.xxxx.xxx.xxx": {
    "ptagentversion": "2.4.1-3",
    "uptime": "595 seconds ( 9 minutes 55 seconds )",
    "ism_version": "3.6.0",
    "system_uuid": "618axxxx-xxxx-xxxx-xxxx-xxxxxxxxdd70",
    "process_id": "2100391",
    "host_epoch_time": "1646800495.522825 (secs.usecs)",
    "model": "DP4400",
    "name": "<ESXi_hostname>",
    "mfr": "Dell Inc.",
    "domain": "<ESXi FQDN>",
    "servicetag": "XXXXXXX",
    "os": "VMWare ESXi",
    "os_version": "6.7.0 build-17700523",
    "rest_endpoints": "https://127.0.0.1:8086,https://192.168.100.101:8086",
    "api_blocking_enabled": "false",
    "TPM Present": "false",
    "MarvellLibraryVersion": "5.0.13.1109",
    "libstorelib.so": "07.07",
    "libstorelibir-3.so": "15.03-0",
    "libstorelibit.so": "07.05",
    "idrac_pass_thru_ip": "169.254.0.1",
    "idrac_ethernet_ip": "xxx.xxx.xxx.xxx",
    "host_pass_thru_ip": "169.254.0.2",
    "default_server_cert": "true",
    "status": {
        "idraccache": "OK",
        "idracConnection": "OK",
        "iSM": "N/A",
        "agent": "OK"
    }
}}]}
ACM:~ #
  1. Spusťte znovu nástroj RUCK pro kontrolu stavu a ověřte, zda byl problém vyřešen.

Additional Information

Balíček firmwaru "PowerProtect DP Series Appliance-IDPA Firmware Gen14 December 2021" lze stáhnout z webu podpory společnosti Dell:
Firmware
Obrázek 7: Firmware "PowerProtect DP Series Appliance-IDPA Firmware Gen14 December 2021" je k dispozici na webu podpory společnosti Dell.

Extrahování firmwaru z IDPA_Firmware_Gen14_Update_Dec_2021_Package.ziprozbalte všechny soubory balíčku: "dpafw-2.312.rpm" > "dpafw-2.312-0.noarch.cpio" > "IDPA-2.312-2.312.tar.gz" > "IDPA-2.312-2.312.tar",> pak soubor firmwaru najdete v části DUPS > NVME:

Příklad extrahování firmwaru NVMe PM1735 ze sady firmwaru zařízení PowerProtect řady DP – firmware IDPA Gen14 z prosince 2021Obrázek 8: Příklad extrahování firmwaru NVMe PM1735 z balíčku firmwaru "PowerProtect DP Series Appliance-IDPA Firmware Gen14 December 2021".

 

Affected Products

PowerProtect DP4400, PowerProtect Data Protection Software, Integrated Data Protection Appliance Family, PowerProtect Data Protection Hardware, Integrated Data Protection Appliance Software
Article Properties
Article Number: 000197174
Article Type: Solution
Last Modified: 05 Aug 2025
Version:  10
Find answers to your questions from other Dell users
Support Services
Check if your device is covered by Support Services.