Summary: Enheder i PowerProtect Data Protection (DP)-serien og IDPA: PowerProtect DP Rapid Upgrade Checker (RUCK) rapporterede, at en forhåndskontrol af firmwareopgraderingen mislykkedes. Det cachelagrede svar med Node Event Service er deaktiveret. Nodehændelsestjenesten er i en forringet tilstand, og iDRAC-servicemodulet er ikke tilgængeligt/aktivt i øjeblikket. Kontrollér status for iDRAC Service Module/iDRAC. Dette kan skyldes forældet NVMe PM1735-kortfirmware i PCIe SSD-slot 4. ...

This article applies to This article does not apply to This article is not tied to any specific product. Not all product versions are identified in this article.

Symptoms

PowerProtect Data Protection Rapid Upgrade Checker (RUCK) mislykkes med følgende fejl:

+-----------+--------------------+--------+-----------------------------------------------+-----------------------------------------------+
| Component | Check              | Status | Message                                       | Remedy                                        |
+-----------+--------------------+--------+-----------------------------------------------+-----------------------------------------------+
| ESXi      | firmware_readiness | FAILED | Firmware pre-upgrade checks failed. [ xxx.xxx.| Use KB https://www.dell.com/support/kbdoc/191 |
|           |                    |        | xxx.xxx ]: The cached response with Node Event| 627 to fix the issue.                         |
|           |                    |        | Service is disabled. Node Event Service is in |                                               |
|           |                    |        |  a degraded state,iDRAC Service Module is not |                                               |
|           |                    |        |  available/active at this time. Check iDRAC S |                                               |
|           |                    |        | ervice Module/iDRAC status.                   |                                               |
+-----------+--------------------+--------+-----------------------------------------------+-----------------------------------------------+
[ERROR] Firmware pre-upgrade checks failed. [ <ESXi IP Address> ]: The cached response with Node Event Service is disabled. Node Event Service is in a degraded state, iDRAC Service Module is not available/active at this time. Check iDRAC Service Module/iDRAC status.

Hardwaremodellen på PCIe SSD i slot 4 er et Dell Enterprise NVMe AGN MU AIC 1.6 TB-kort (NVMe PM1735), og firmwaren er under version 2.3.0.

PCIe SSD-kortmodellen og firmwareversionen er beskrevet på iDRAC. > Systemfysiske diske > PCIe-enhed – PCIe SSD i slot 4 Disk 1

I dette eksempel er PCIe SSD-kortet en PM1725b. Derfor er løsningen ikke relevant i dette tilfælde:

Sådan finder du PCIe SSD-kortet fra iDRAC-brugergrænsefladen

Figur 1: Sådan finder du PCIe SSD-kortet fra iDRAC-brugergrænsefladen.


I loggen over Dell iDRAC Technical Support Report (TSR) hedder PCIe SSD-kortet "Dell Ent NVMe AGN MU AIC 1,6 TB":

Fra TSR-loggen hedder NVMe PM1735-kortet Dell Ent NVMe AGN MU AIC 1,6 TB

Figur 2: Fra TSR-loggen hedder NVMe PM1735-kortet Dell Ent NVMe AGN MU AIC 1,6 TB.

iDRAC Service Module (iSM) vises som Kører i iDRAC-brugergrænsefladen:

iSM-status kører

Figur 3: iSM-status kører.

Dell PT Agent og iSM kører, og problemet fortsætter efter genstart:

[root@ESXi:/opt/dell/DellPTAgent/tools] /etc/init.d/DellPTAgent status
DellPTAgent is running
[root@ESXi:/opt/dell/DellPTAgent/tools] /etc/init.d/DellPTAgent stop
Stopping DellPTAgent...
watchdog-DellPTAgent: Terminating watchdog process with PID 7447869
DellPTAgent stopped
[root@ESXi:/opt/dell/DellPTAgent/tools] /etc/init.d/DellPTAgent start
Starting DellPTAgent...
DellPTAgent started
[root@ESXi:/opt/dell/DellPTAgent/tools] /etc/init.d/DellPTAgent status
DellPTAgent is running
[root@ESXi:/opt/dell/DellPTAgent/tools]

[root@ESXi:/opt/dell/DellPTAgent/tools] /etc/init.d/dcism-netmon-watchdog status
iSM is active (running)
[root@ESXi:/opt/dell/DellPTAgent/tools] /etc/init.d/dcism-netmon-watchdog stop
Module dcism_module successfully unloaded
[root@ESXi:/opt/dell/DellPTAgent/tools] /etc/init.d/dcism-netmon-watchdog start
[root@ESXi:/opt/dell/DellPTAgent/tools] /etc/init.d/dcism-netmon-watchdog status
iSM is active (running)
[root@ESXi:/opt/dell/DellPTAgent/tools]

Cause

Fra ACM viser det, at iDRAC-cachen er forringet:

ACM:/tmp # dpacli -agentinfo
{"Agent Info": [{"ESXiHost-xxx.xxxx.xxx.xxx": {
    "ptagentversion": "2.4.1-3",
    "uptime": "54 seconds ( 54 seconds )",
    "ism_version": "3.6.0",
    "system_uuid": "618axxxx-xxxx-xxxx-xxxx-xxxxxxxxdd70",
    "process_id": "7440642",
    "host_epoch_time": "1646617738.156490 (secs.usecs)",
    "model": "DP4400",
    "name": "<ESXi_hostname>",
    "mfr": "Dell Inc.",
    "domain": "<ESXi FQDN>",
    "servicetag": "XXXXXXX",
    "os": "VMWare ESXi",
    "os_version": "6.7.0 build-17700523",
    "rest_endpoints": "https://127.0.0.1:8086,https://192.168.100.101:8086",
    "api_blocking_enabled": "false",
    "TPM Present": "false",
    "MarvellLibraryVersion": "5.0.13.1109",
    "libstorelib.so": "07.07",
    "libstorelibir-3.so": "15.03-0",
    "libstorelibit.so": "07.05",
    "idrac_pass_thru_ip": "169.254.0.1",
    "idrac_ethernet_ip": "xx.xxx.xxx.x",
    "host_pass_thru_ip": "169.254.0.2",
    "default_server_cert": "true",
    "status": {
        "idraccache": "Degraded",
        "idracConnection": "OK",
        "iSM": "N/A",
        "agent": "Degraded"
    }
}}]}
ACM:/tmp #

Og de samme oplysninger ses, når du trækker fra ESXi:

[root@ESXi:~] /opt/dell/DellPTAgent/tools/pta_call get agent/info
Request sent to DellPTAgent @ https://192.168.100.101:8086
{
    "TPM Present": "false",
    "MarvellLibraryVersion": "5.0.13.1109",
    "uptime": "344 seconds ( 5 minutes 44 seconds )",
    "system_uuid": "618axxxx-xxxx-xxxx-xxxx-xxxxxxxxdd70",
    "host_pass_thru_ip": "169.254.0.2",
    "servicetag": "XXXXXXX",
    "domain": "<ESXi FQDN>",
    "default_server_cert": "true",
    "libstorelibir-3.so": "15.03-0",
    "model": "DP4400",
    "idrac_ethernet_ip": "xxx.xxx.xxx.xxx",
    "os": "VMWare ESXi",
    "rest_endpoints": "https://127.0.0.1:8086,https://192.168.100.101:8086",
    "mfr": "Dell Inc.",
    "api_blocking_enabled": "false",
    "libstorelib.so": "07.07",
    "ptagentversion": "2.4.1-3",
    "ism_version": "3.6.0",
    "host_epoch_time": "1646618523.10088 (secs.usecs)",
    "os_version": "6.7.0 build-17700523",
    "libstorelibit.so": "07.05",
    "idrac_pass_thru_ip": "169.254.0.1",
    "name": "<ESXi_hostname>",
    "process_id": "7441193",
    "status": {
        "idraccache": "Degraded",
        "idracConnection": "OK",
        "agent": "Degraded",
        "iSM": "N/A"
    }
}
Response: status: 200 [OK], size: 1067 bytes, latency: 0.145 seconds.
[root@ESXi:~]

I dette tilfælde kunne PT-agenten ikke finde komponenten »PhysicalDisk« i hwInventory fordi den har problemer med at forespørge på data fra NVMe PM1735-kortet i slot 4.

Fra ESXi /scratch/log/pta_debug.log vises fejlmeddelelsen:

2022/03/07 04:51:03[UTC] [7459005:193227584] WARN  - WSManClient::isValidResponse: Http request to host: 169.254.0.1, failed with status code: -5
2022/03/07 04:51:03[UTC] [7459005:193227584] WARN  - getComponentFromInventory: Cannot find component 'PhysicalDisk' in hwInventory:
{
    "Message": "Read timed out!",
    "ReturnValue": -5
}
2022/03/07 04:52:57[UTC] [7459005:189000512] WARN  - NvmeDiscoveredDevice::setIntAttrFromDescriptor: Cannot convert string <ie> to int.
2022/03/07 04:52:57[UTC] [7459005:189000512] WARN  - NvmeDiscoveredDevice::setIntAttrFromDescriptor: Failed to read <bay> from <PCIe Slot 4>

Derfor foreslås det at opgradere NVMe 1735-firmware til version 2.3.0, som er samlet i "PowerProtect Data Protection Appliance-IDPA Firmware Gen14 December 2021." Den krævede firmwarefil er: Express-Flash-PCIe-SSD_Firmware_RP8RC_WN64_2.3.0_A03.EXE

Resolution

Bemærk: Følgende løsning kan kun gælde for NVMe 1735 med firmwareversion under 2.3.0 og dækker IKKE NVMe-modellerne 1725, 1725a og 1725b.


Sådan opgraderes NVMe 1735-firmwaren til version 2.3.0:

  1. Download "PowerProtect Data Protection Series Appliance-IDPA Firmware Gen14 December 2021" fra Dell Support Web, og pak derefter den nødvendige firmwarefil ud Express-Flash-PCIe-SSD_Firmware_RP8RC_WN64_2.3.0_A03.EXE.

  2. Luk den integrerede databeskyttelsesenhed fra ACM-webbrugergrænsefladen.

  3. Når du har bekræftet, at ESXi er slukket, skal du logge på iDRAC-brugergrænsefladen og derefter manuelt uploade firmwarefilen til iDRAC:
    Sådan uploader du firmware i iDRAC-brugergrænsefladen
    Figur 4: Sådan uploader du firmware i iDRAC-brugergrænsefladen

  4. Vælg ikonet Express-Flash-PCIe-SSD_Firmware_RP8RC_WN64_2.3.0_A03.EXE fil, og klik på Installer og genstart. Derefter installerer iDRAC firmwaren og genstarter.
    Sådan uploader du firmware i iDRAC-brugergrænsefladen
    Figur 5: Sådan anvendes firmwaren

  5. Efter genstart kan firmwareversionen kontrolleres i iDRAC >System Inventory >Firmware Inventory:
    Sådan gennemser du firmwaren fra firmwareoversigten
    Figur 6: Sådan gennemser du firmwaren fra firmwareoversigten

  6. Overvågning af DP4400-opstarten og efter alle de virtuelle maskiner opstart med succes.
  7. Kør dpacli kommandere igen i ACM, og bekræft, at ikonet idraccache og agentstatus skal ændres til OK:
ACM:~ # dpacli -agentinfo
{"Agent Info": [{"ESXiHost-xxx.xxxx.xxx.xxx": {
    "ptagentversion": "2.4.1-3",
    "uptime": "595 seconds ( 9 minutes 55 seconds )",
    "ism_version": "3.6.0",
    "system_uuid": "618axxxx-xxxx-xxxx-xxxx-xxxxxxxxdd70",
    "process_id": "2100391",
    "host_epoch_time": "1646800495.522825 (secs.usecs)",
    "model": "DP4400",
    "name": "<ESXi_hostname>",
    "mfr": "Dell Inc.",
    "domain": "<ESXi FQDN>",
    "servicetag": "XXXXXXX",
    "os": "VMWare ESXi",
    "os_version": "6.7.0 build-17700523",
    "rest_endpoints": "https://127.0.0.1:8086,https://192.168.100.101:8086",
    "api_blocking_enabled": "false",
    "TPM Present": "false",
    "MarvellLibraryVersion": "5.0.13.1109",
    "libstorelib.so": "07.07",
    "libstorelibir-3.so": "15.03-0",
    "libstorelibit.so": "07.05",
    "idrac_pass_thru_ip": "169.254.0.1",
    "idrac_ethernet_ip": "xxx.xxx.xxx.xxx",
    "host_pass_thru_ip": "169.254.0.2",
    "default_server_cert": "true",
    "status": {
        "idraccache": "OK",
        "idracConnection": "OK",
        "iSM": "N/A",
        "agent": "OK"
    }
}}]}
ACM:~ #
  1. Kør Health Check RUCK-værktøjet igen for at bekræfte, om problemet er blevet løst.

Additional Information

Firmwarepakken "PowerProtect DP Series Appliance-IDPA Firmware Gen14 December 2021" kan downloades fra Dell Support-websiden:
Firmwaren
Figur 7: Firmwaren "PowerProtect DP Series Appliance-IDPA Firmware Gen14 December 2021" er tilgængelig på Dell Support-websiden.

Sådan udpakkes firmwaren fra IDPA_Firmware_Gen14_Update_Dec_2021_Package.zip, udpak alle bundtfilerne: "dpafw-2.312.rpm" > "dpafw-2.312-0.noarch.cpio" > "IDPA-2.312-2.312.tar.gz" > "IDPA-2.312-2.312.tar",> så kan firmwarefilen findes under DUPS > NVME:

Et eksempel på udpakning af NVMe PM1735-firmwaren fra PowerProtect DP-seriens enhed – IDPA Firmware Gen14 December 2021-firmwarepakkeFigur 8: Et eksempel på udpakning af NVMe PM1735-firmwaren fra firmwarepakken "PowerProtect DP Series Appliance-IDPA Firmware Gen14 December 2021".

 

Affected Products

PowerProtect DP4400, PowerProtect Data Protection Software, Integrated Data Protection Appliance Family, PowerProtect Data Protection Hardware, Integrated Data Protection Appliance Software
Article Properties
Article Number: 000197174
Article Type: Solution
Last Modified: 05 Aug 2025
Version:  10
Find answers to your questions from other Dell users
Support Services
Check if your device is covered by Support Services.