ECS: resourcesvc som studsar på grund av överdriven minnesförbrukning
Summary: Tjänsten resourcesvc kan startas om kontinuerligt om orsaken till överdriven minnesförbrukning inte åtgärdas.
This article applies to
This article does not apply to
This article is not tied to any specific product.
Not all product versions are identified in this article.
Symptoms
De senaste uppdateringarna av ILM-principer
Resourcesvc startar om hela tiden:
admin@node1:~> svc_node services -sr svc_node v1.1.0 (svc_tools v1.6.6) Started 2019-11-20 18:32:20 Total Restarts on each node (all services) from 7 hours ago to now: Node # Service Restarts -------------------------------- 169.254.1.1 1 169.254.1.2 84 169.254.1.3 1 169.254.1.4 43 169.254.1.5 51 169.254.1.6 72 169.254.1.7 0 169.254.1.8 13 Aggregate restarts on nodes 'all': Time blbsvc cm crdsvc datahd dtq evntsv georcv metrng objctl portal rm rsrcsv sr ss ssm stat vnest -------------------------------------------------------------------------------------------------------------------------------------------------------- 2019-11-20 11:xx - - - - - - - - - - - 38 - - - - - 2019-11-20 12:xx - - - - - - - - - - - 36 - - - - - 2019-11-20 13:xx - - - - - - - - - - - 30 - - - - -
RR eller RT DT studsar mellan redo och inte redo
admin@Rack1Node1:~> svc_dt check svc_dt v1.0.20 (svc_tools v1.6.6) Started 2019-11-20 19:32:48 Date Total DT Unknown # Unready # Check type Time since check 2019-11-20 19:28:01 1920 0 58 AutoCheck 4m 47s 2019-11-20 19:22:31 1920 2 46 AutoCheck 10m 17s 2019-11-20 19:16:41 1920 0 0 AutoCheck 16m 7s 2019-11-20 19:11:26 1920 0 16 AutoCheck 21m 22s BR1 BR2 CT1 CT2 ET0 LS0 MA0 MR0 OB0 PR1 PR2 RR0 RT0 SS1 SS2 TT0 Date Unk Unr|Unk Unr|Unk Unr|Unk Unr|Unk Unr|Unk Unr|Unk Unr|Unk Unr|Unk Unr|Unk Unr|Unk Unr|Unk Unr|Unk Unr|Unk Unr|Unk Unr|Unk Unr| 2019-11-20 19:28:01 0 0 |0 0 |0 0 |0 0 |0 0 |0 0 |0 0 |0 0 |0 0 |0 0 |0 0 |0 0 |0 58 |0 0 |0 0 |0 0 | 2019-11-20 19:22:31 0 0 |0 0 |0 0 |0 0 |0 0 |0 0 |0 0 |0 0 |0 0 |0 0 |0 0 |0 0 |2 46 |0 0 |0 0 |0 0 |
Loggen resourcesvc visar liknande minnesproblem:
169.254.1.1 2019-11-15T20:03:16,427 [Thread-16] ERROR ProcessMonitor.java (line 264) heap memory usage (99%) exceeded threshold (85%) 169.254.1.1 2019-11-15T20:03:16,428 [Thread-16] ERROR ServiceMemoryListener.java (line 47) WSCritical. Memory usage threshold exceeded. usedMemory=1028612296, percentageUsed=99.09949521251302
Klienten läser in gränssnittssidor
Kontrollera att tjänsten startas om över /var/log/warn i object-main-containern.# svc_exec -c "grep restart /var/log/warn | tail -2"
admin@ecsnode1:~> svc_exec -c "grep restart /var/log/warn | tail -2" svc_exec v1.0.6 (svc_tools v2.11.1) Started 2023-04-27 18:01:41 Output from node: r1n1 (object-main) retval: 0 2023-04-27T17:56:56.028973+00:00 gf01rsso833v-pub01 monitor: Process /opt/storageos/bin/resourcesvc is restarting. 2023-04-27T17:59:18.281755+00:00 gf01rsso833v-pub01 monitor: Process /opt/storageos/bin/resourcesvc is restarting. Output from node: r1n2 (object-main) retval: 0 2023-04-27T17:44:17.243145+00:00 gf01rsso833v-pub02 monitor: Process /opt/storageos/bin/resourcesvc is restarting. 2023-04-27T17:51:58.026469+00:00 gf01rsso833v-pub02 monitor: Process /opt/storageos/bin/resourcesvc is restarting. Output from node: r1n3 (object-main) retval: 0 2023-04-27T17:49:30.865189+00:00 gf01rsso833v-pub03 monitor: Process /opt/storageos/bin/resourcesvc is restarting. 2023-04-27T17:57:22.368574+00:00 gf01rsso833v-pub03 monitor: Process /opt/storageos/bin/resourcesvc is restarting. Output from node: r1n4 (object-main) retval: 0 2023-04-27T17:40:11.327713+00:00 gf01rsso833v-pub04 monitor: Process /opt/storageos/bin/resourcesvc is restarting. 2023-04-27T17:59:24.566502+00:00 gf01rsso833v-pub04 monitor: Process /opt/storageos/bin/resourcesvc is restarting. Output from node: r1n5 (object-main) retval: 0 2023-04-27T17:50:35.589292+00:00 gf01rsso833v-pub05 monitor: Process /opt/storageos/bin/resourcesvc is restarting. 2023-04-27T18:01:09.344803+00:00 gf01rsso833v-pub05 monitor: Process /opt/storageos/bin/resourcesvc is restarting. Output from node: r1n6 (object-main) retval: 0 2023-04-27T17:39:39.480222+00:00 gf01rsso833v-pub06 monitor: Process /opt/storageos/bin/resourcesvc is restarting. 2023-04-27T17:51:49.229058+00:00 gf01rsso833v-pub06 monitor: Process /opt/storageos/bin/resourcesvc is restarting. Output from node: r1n7 (object-main) retval: 0 2023-04-27T17:58:08.383501+00:00 gf01rsso833v-pub07 monitor: Process /opt/storageos/bin/resourcesvc is restarting. 2023-04-27T18:00:00.346869+00:00 gf01rsso833v-pub07 monitor: Process /opt/storageos/bin/resourcesvc is restarting. Output from node: r1n8 (object-main) retval: 0 2023-04-27T17:41:11.263187+00:00 gf01rsso833v-pub08 monitor: Process /opt/storageos/bin/resourcesvc is restarting. 2023-04-27T18:00:10.438252+00:00 gf01rsso833v-pub08 monitor: Process /opt/storageos/bin/resourcesvc is restarting.
Cause
resourcesvc-minnet kan påverkas av överanvändning av ILM-principer.
Resolution
Öppna en tjänstebegäran med ECS-support för att få problemet undersökt, med hänvisning till denna KB.
Affected Products
ECS Appliance, ECS SoftwareArticle Properties
Article Number: 000063163
Article Type: Solution
Last Modified: 26 Sept 2025
Version: 5
Find answers to your questions from other Dell users
Support Services
Check if your device is covered by Support Services.