Can I create LUN 0 from two separate arrays on one ESXi host

Summary: Can I create LUN 0 from two separate arrays on one ESXi host?

This article applies to This article does not apply to This article is not tied to any specific product. Not all product versions are identified in this article.

Instructions

Customer sees LUNZ from two arrays, causing performance issues.

It is possible to create LUN 0 from two separate arrays on one ESXi host. ESXi host and multipathing software see the LUNs as separate entities both due to the naa unique ID and the unique paths to the device.

 

The below example of a host that is attached to two different Clariion arrays, the LUN 0 on each array has a distinct path:

naa.600601xxxxxxxxxxxxxxxxx0
Clariion 4xxxxxxx0

vmhba1:C0:T0:L0

Active

fc

WWNN: 20:00:00:xx:xx:xx:00:00 WWPN: 20:00:00:0:xx:xx:xa00:00 WWNN: 50:xx:xx:xx:xx:xx:xx:xx  WWPN: 50:xx:xx:xx:xx:xx:xx:70 (dir = B6)

vmhba1:C0:T1:L0

Active

fc

WWNN: 20:00:00:0:xx:xx:xx:00:00 WWPN: 20:00:00:0:xx:xx:a:00:00 WWNN: 50:xx:xx:xx:xx:xx:xx:xx  WWPN: 50:xx:xx:xx:xx:xx:xx:70 (dir = A9)

vmhba2:C0:T0:L0

Active

fc

WWNN: 20:00:00:0:xx:xx:xx:00:00 WWPN: 20:00:000:xx:xx:xx:00:00 WWNN: 50:xx:xx:xx:xx:xx:xx:xx  WWPN: 50:xx:xx:xx:xx:xx:xx:70 (dir = B11)

vmhba1:C0:T2:L0

Active

fc

WWNN: 20:00:00:xx0:xx:xx:00:00 WWPN: 20:00:00:0:xx:xx:xx:00:00 WWNN: 50:xx:xx:xx:xx:xx:xx:xx  WWPN: 50:xx:xx:xx:xx:xx:xx:70 (dir = B1)

vmhba2:C0:T1:L0

Active

fc

WWNN: 20:00:00:0:xx:xx:xx:00:00 WWPN: 20:00:00:0:xx:xx:xx:00:00 WWNN: 50:xx:xx:xx:xx:xx:xx:xx  WWPN: 50:xx:xx:xx:xx:xx:xx:70(dir = A11)

vmhba1:C0:T3:L0

Active

fc

WWNN: 20:00:000:xx:xx:xx:00:00 WWPN: 20:00:00:0:xx:xx:xx::00:00 WWNN: 50:xx:xx:xx:xx:xx:xx:xx  WWPN: 50:xx:xx:xx:xx:xx:xx:70 (dir = A5)

vmhba2:C0:T2:L0

Active

fc

WWNN: 20:00:00:0:xx:xx:xx:00:00 WWPN: 20:00:000:xx:xx:xx:00:00 WWNN: 50:xx:xx:xx:xx:xx:xx:xx  WWPN: 50:xx:xx:xx:xx:xx:xx:70 (dir = A7)

vmhba2:C0:T3:L0

Active

fc

WWNN: 20:00:00:0:xx:xx:xx::00:00 WWPN: 20:00:00:0:xx:xx:xx::00:00 WWNN: 50:xx:xx:xx:xx:xx:xx:xx  WWPN: 50:xx:xx:xx:xx:xx:xx:70 (dir = B7)

 

naa.600601xxxxxxxxxxxxxxxxxxxxxxxxxx1
Clariion 4xxxxxxb

vmhba2:C0:T4:L0

Active

fc

WWNN: 20:00:00:xx:xx:xx:00:00 WWPN: 20:00:00:0:xx:xx:xb:00:00 WWNN: 50:xx:xx:xx:xx:xx:xx:xx  WWPN: 50:xx:xx:xx:xx:xx:xx::fb (dir = B4)

vmhba2:C0:T5:L0

Active

fc

WWNN: 20:00:00:xx:xx:xx:00:00 WWPN: 20:00:00:0:xx:xx:xb:00:00 WWNN: 50:xx:xx:xx:xx:xx:xx:xx  WWPN: 50:xx:xx:xx:xx:xx:xx::fb (dir = A8)

vmhba1:C0:T5:L0

Active

fc

WWNN: 20:00:00:xx:xx:xx:00:00 WWPN: 20:00:00:0:xx:xx:xa:00:00 WWNN: 50:xx:xx:xx:xx:xx:xx:xx  WWPN: 50:xx:xx:xx:xx:xx:xx:fb (dir = A5)

vmhba1:C0:T4:L0

Active

fc

WWNN: 20:00:00:xx:xx:xx:00:00 WWPN: 20:00:00:0:xx:xx:xa:00:00 WWNN: 50:xx:xx:xx:xx:xx:xx:xx  WWPN: 50:xx:xx:xx:xx:xx:xx::fb (dir = B9)

 

Affected Products

VMware ESXi 4.x

Products

VMware ESXi 5.x, VMware ESXi 6.5.X, VMware ESXi 8.x
Article Properties
Article Number: 000204532
Article Type: How To
Last Modified: 31 Jul 2024
Version:  3