PowerEdge: 17Gen Performance throttle post PSU cable removal in iDRAC10

Summary: Performance drops after power supply unit (PSU) cable removal and does not recover upon reconnection, despite the A/B Grid Redundant policy being active in iDRAC10.

This article applies to This article does not apply to This article is not tied to any specific product. Not all product versions are identified in this article.

Symptoms

When the PSU power is removed, an alert occurs, which throttles the CPU as expected. However, after the PSU is reinserted, the SMB alerts are not cleared, causing the CPU throttling to continue.
This issue is observed with two Power Supply Unit (PSU) configurations. (Redundancy Policy - A/B Grid Redundant)
The issue is observed only when one PSU is removed and inserted back into the server.
A reduction in CPU performance and network bandwidth is anticipated with the loss of a PSU.

 

iDRAC power supply GUI

 

 

 

Cause

iDRAC10 firmware is not clearing the SMB alert.

Resolution

Fixed in iDRAC10 firmware version 1.10.17.00

Workaround:
Perform an AC power cycle or Virtual AC cycle.

Affected Products

OEMR XL R6715, OEMR XL R6725, OEMR XL R7715, OEMR XL R7725, PowerEdge R570, PowerEdge R670, PowerEdge R6715, PowerEdge R6725, PowerEdge R770, PowerEdge R7715, PowerEdge R7725, PowerEdge R7725xd
Article Properties
Article Number: 000247062
Article Type: Solution
Last Modified: 07 Jul 2025
Version:  2
Find answers to your questions from other Dell users
Support Services
Check if your device is covered by Support Services.