Cisco MDS:设置引导变量失败,并显示“实际映像类型与引导变量 (0x4045001E) 不匹配”

Summary: 客户执行从 NX-OS 6.2.23 到 9.4.2a 的中断升级。

This article applies to This article does not apply to This article is not tied to any specific product. Not all product versions are identified in this article.

Symptoms

用于设置引导变量的语法如下:
switch(config)#
no boot system
switch(config)#
boot bootflash:<kickstart new_kickstart_image_name>
switch(config)#
boot bootflash:<system new_system_image_name>
switch(config)#
end
switch#
copy running-config startup-config
switch#
reload

在 MDS 9148S 上运行以下命令的客户:
MDS9148S(config)# boot kickstart bootflash:m9148-s6ek9-kickstart-mz.9.4.2a.bin

Performing image verification and compatibility check, please wait....
Failed to configure bootvar kickstart for sup-1: mismatch between actual image type and boot variable (0x4045001E)

Cause

Cisco MDS9148s 平台使用的映像不正确:
从 MDS9148s:
MDS9148s# show version
  kickstart image file is: bootflash:///m9100-s5ek9-kickstart-mz.6.2.23.bin
  kickstart compile time:  3/31/2018 23:00:00 [02/20/2018 18:47:57]
  system image file is:    bootflash:///m9100-s5ek9-mz.6.2.23.bin
  system compile time:     3/31/2018 23:00:00 [02/20/2018 19:58:46]

请注意,show version from switch 是:
-m9100-s5ek9
但是尝试使用来自不同平台的映像设置引导变量将失败:
-m9148-s6ek9

Resolution

确保每个平台
都使用正确的系统/Kickstart 映像 可从中下载每种交换机类型的平台映像:https://www.dell.com/support/home/en-ie/product-support/product/connectrix/drivers

Affected Products

Connectrix MDS-9148S
Article Properties
Article Number: 000249589
Article Type: Solution
Last Modified: 12 Mar 2025
Version:  2
Find answers to your questions from other Dell users
Support Services
Check if your device is covered by Support Services.