PowerFlex storcli add vd 命令报告“hard drive does not have appropriate attributes”(硬盘驱动器没有适当的属性)

Summary: Storcli add vd 命令报告“hard drive does not have appropriate attributes”(硬盘驱动器没有适当的属性)

This article applies to This article does not apply to This article is not tied to any specific product. Not all product versions are identified in this article.

Symptoms

情况说明

在未遵循正确步骤的情况下将磁盘从机柜中拉出并放回时,可能会发生这种情况。

这可能发生在使用 LSI 控制器和 storcli 的 VxRack 节点和其他系统上。

症状

storcli 上的错误添加了 vd 命令:

 # /opt/MegaRAID/storcli/storcli64 /c0 add vd type=raid0 drives=252:2 direct wb ra
Controller = 0
Status = Failure
Description = physical disk does not have appropriate attributes

在“storcli /c0 show”输出中,252:2 的状态为“UBad”,DG 为“F”:

 # /opt/MegaRAID/storcli/storcli64 /c0 show
...
PD LIST :
=======
----------------------------------------------------------------------------
EID:Slt DID State DG Size Intf Med SED PI SeSz Model Sp
----------------------------------------------------------------------------
252:0 13 Onln 4 372.093 GB SATA SSD N N 512B INTEL SSDSC2BA400G3 U
252:1 12 Onln 0 837.843 GB SAS HDD Y N 512B ST900MM0026 U
252:2 11 UBad F 837.843 GB SAS HDD Y N 512B ST900MM0026 U
252:4  8 Onln 1 837.843 GB SAS HDD Y N 512B ST900MM0026 U
252:5  9 Onln 2 837.843 GB SAS HDD Y N 512B ST900MM0026 U
252:6 10 Onln 3 837.843 GB SAS HDD Y N 512B ST900MM0026 U

 

影响

无法使用磁盘。

Cause

当磁盘被拉出并放回时,控制器可能会认为此磁盘的配置是“外部的”(DG=F)。这会阻止控制器使用磁盘,并且尝试在此 PD 上添加虚拟磁盘将失败。

 

Resolution

必须先删除外部配置,然后控制器才能使用 PD。

提醒:此作会使磁盘上的数据失效。这应该不会导致 ScaleIO 出现问题,因为所有数据都有两个副本。

1.清除物理磁盘的“Ubad”状态(如果有):

# /opt/MegaRAID/storcli/storcli64 /c0/e252/s2 set good
Controller = 0
Status = Success
Description = Set Drive Good Succeeded.

2.使用“storcli /c0/fall show”验证外部配置

# /opt/MegaRAID/storcli/storcli64 /c0/fall show
Controller = 0
Status = Success
Description = Operation on foreign configuration Succeeded
FOREIGN CONFIGURATION :
=====================
-----------------------------------------
DG EID:Slot Type  State       Size NoVDs
-----------------------------------------
 0 -        RAID0 Frgn  837.843 GB     1
-----------------------------------------
NoVDs - Number of VDs in disk group|DG - Diskgroup
Total foreign drive groups = 1

3.使用“storcli /c0/fall del”删除外部配置

# /opt/MegaRAID/storcli/storcli64 /c0/fall del
Controller = 0
Status = Success
Description = Successfully deleted foreign configuration

之后,“storcli /c0 show”将显示具有有效 DG 编号的 UGood 状态的物理磁盘,并且该物理磁盘可以再次用于“add vd”命令。