Connectrix MDS Series: FC Module in Powered down status due to System Error code "0x42630007 mauler obt bist failure"

Summary: Hardware failure is detected by the Built-In Self Test (BIST) on one of the F16 ASICs

This article applies to This article does not apply to This article is not tied to any specific product. Not all product versions are identified in this article.

Symptoms



BIST (Built-In Self Test) Failure encountered on Port Blade Module .

`show module`
Mod  Ports  Module-Type                         Model              Status
---  -----  ----------------------------------- ------------------ ----------
8    48     2/4/8/10/16 Gbps Advanced FC Module DS-X9448-768K9     powered-dn

`show module internal exceptionlog module 8`
Module Slot Number: 8
Device Id         : 204
Device Name       : F16 Generic Driver
Device Errorcode  : 0xccc01400
Device ID         : 204 (0xcc)
Device Instance   : 01 (0x01)
Dev Type (HW/SW)  : 04 (0x04)
ErrNum (devInfo)  : 00 (0x00)
System Errorcode  : 0x42630007 mauler obt bist failure
Error Type        : Minor error
PhyPortLayer      : Fibre Channel
Port(s) Affected  : fc8/9-16
Error Description : hardware init failure
DSAP              : 0 (0x0)
UUID              : 1129 (0x469)
Time              : Fri Jun 26 01:05:56 2020
                    (Ticks: 5EF59044 jiffies) 

Mod  Power-Status  Reason 
---  ------------  ---------------------------
8    powered-dn     Reset (powered-down) because module does not boot

show logging log:

2020 Jun 26 01:04:06 CMISAN-10 %MODULE-2-MOD_SOMEPORTS_FAILED: Module 8 (Serial number: XXXXXXXXXXX) reported failure on ports fc8/9-16 (Fibre Channel) due to mauler obt   bist failure in device DEV_F16_CMN (device error 0xccc01400)
2020 Jun 26 01:05:01 CMISAN-10 %PORT-5-MODULE_BRINGUP_NOT_ALLOWED: Not allowing module 8 to come up for reason: Device Name:[0xC4] Instance:[38] Error Type:[diag error]   code:[0] (0xcc426300)

 

Cause

BIST (Built-In Self Test) is a part of POST (Power On Self Test). BIST is basically a diagnostic test meant to detect hardware failures. The different switches that are part of the MDS platform, supports a whole set of diagnostic tests, and that includes BIST. 

When a chip gets corrupted, as a result BIST fails. This is an issue with hardware failure on one of the F16 ASICs inside Port blade module.

In the above case - BIST is getting failed for one of the ASIC which is responsible for ports (9-16).

Resolution

The Module needs to be replaced as this is a Hardware ASIC Failure.

Affected Products