Serie Connectrix MDS: El firmware del cargador en la salida de show version muestra NA

Summary: El firmware del cargador en la salida de show version muestra N/A.

This article applies to This article does not apply to This article is not tied to any specific product. Not all product versions are identified in this article.

Symptoms

Todos los switches de fabric (independientemente de NX-OS) muestran la versión del cargador (S, T y V) como N/A. Desde la versión 6.x hasta la 9.x, solo se muestra N/A:
Software
  BIOS:      version 2.1.19
  loader:    version N/A        <<<<<<<<< loader version displayed as N/A
  kickstart: version 9.4(2a)
  system:    version 9.4(2a)
  BIOS compile time:       05/15/23
  kickstart image file is: bootflash:///m9100-s5ek9-kickstart-mz.9.4.2a.bin     <<<<<< 9148S
  kickstart compile time:  7/15/2024 12:00:00 [07/22/2024 16:53:33]
  system image file is:    bootflash:///m9100-s5ek9-mz.9.4.2a.bin
  system compile time:     7/15/2024 12:00:00 [07/22/2024 18:31:20]

Software
  BIOS:      version 1.47.0
  loader:    version N/A      <<<<<<<<< loader version displayed as N/A
  kickstart: version 9.4(1a)
  system:    version 9.4(1a)
  BIOS compile time:       03/14/2024
  kickstart image file is: bootflash:///m9100-s6ek9-kickstart-mz.9.4.1a.bin      <<<<< 9132T
  kickstart compile time:  12/25/2023 12:00:00 [01/12/2024 09:04:07]
  system image file is:    bootflash:///m9100-s6ek9-mz.9.4.1a.bin
  system compile time:     12/25/2023 12:00:00 [01/12/2024 10:45:51]

Software
  BIOS:      version 1.07.0
  loader:    version N/A       <<<<<<<<< loader version displayed as N/A
  kickstart: version 9.4(2)
  system:    version 9.4(2)
  BIOS compile time:       12/18/2023
  kickstart image file is: bootflash:///m9124v-s8ek9-kickstart-mz.9.4.2.bin   <<<<<< 9124V
  kickstart compile time:  4/25/2024 12:00:00 [05/09/2024 20:44:44]
  system image file is:    bootflash:///m9124v-s8ek9-mz.9.4.2.bin
  system compile time:     4/25/2024 12:00:00 [05/09/2024 22:26:03]

Los switches de director (independientemente de sup-1, sup-4 o cualquier versión de NX-OS) NO muestran la versión del cargador en el resultado de show version.
Software               <<<<<<<<< no loader version displayed
  BIOS:      version 3.8.0
  kickstart: version 8.4(2f)
  system:    version 8.4(2f)
  BIOS compile time:       04/23/2021
  kickstart image file is: bootflash:///m9700-sf3ek9-kickstart-mz.8.4.2f.bin   <<<<< sup-4
  kickstart compile time:  3/15/2023 12:00:00 [03/25/2023 00:47:55]
  system image file is:    bootflash:///m9700-sf3ek9-mz.8.4.2f.bin
  system compile time:     3/15/2023 12:00:00 [03/25/2023 02:37:14]

Software               <<<<<<<<< no loader version displayed
  BIOS:      version 4.10.0
  kickstart: version 9.4(2a)
  system:    version 9.4(2a)
  BIOS compile time:       03/14/2024
  kickstart image file is: bootflash:///m9700-sf4ek9-kickstart-mz.9.4.2a.bin    <<<<< sup-4
  kickstart compile time:  7/15/2024 12:00:00 [06/12/2024 14:13:36]
  system image file is:    bootflash:///m9700-sf4ek9-mz.9.4.2a.bin
  system compile time:     7/15/2024 12:00:00 [06/12/2024 16:03:45]

Cause

Está diseñado de tal manera que no muestra la versión del cargador. Parece que es por eso que Cisco ha eliminado esa opción en los switches de director.

Resolution

La versión del cargador muestra N/A según el diseño. No tiene ningún impacto en el switch.

Additional Information

La guía de referencia de comandos para la salida de las versiones 8.x y 9.x enumera los detalles de la versión del cargador.
Aquí, la "versión de exhibición" es del switch 9216i, que está EOL/EOS desde 2013. Por lo tanto, podemos ignorarlo.


Affected Products

Connectrix MDS-Series

Products

Connectrix MDS 9132T
Article Properties
Article Number: 000228380
Article Type: Solution
Last Modified: 28 May 2025
Version:  2
Find answers to your questions from other Dell users
Support Services
Check if your device is covered by Support Services.