Symptoms

Tous les commutateurs de fabric (indépendamment de NX-OS) affichent la version du chargeur (S, T et V) comme N/A. De la version 6.x à la version 9.x, elle n’affiche que N/A :
Software
  BIOS:      version 2.1.19
  loader:    version N/A        <<<<<<<<< loader version displayed as N/A
  kickstart: version 9.4(2a)
  system:    version 9.4(2a)
  BIOS compile time:       05/15/23
  kickstart image file is: bootflash:///m9100-s5ek9-kickstart-mz.9.4.2a.bin     <<<<<< 9148S
  kickstart compile time:  7/15/2024 12:00:00 [07/22/2024 16:53:33]
  system image file is:    bootflash:///m9100-s5ek9-mz.9.4.2a.bin
  system compile time:     7/15/2024 12:00:00 [07/22/2024 18:31:20]

Software
  BIOS:      version 1.47.0
  loader:    version N/A      <<<<<<<<< loader version displayed as N/A
  kickstart: version 9.4(1a)
  system:    version 9.4(1a)
  BIOS compile time:       03/14/2024
  kickstart image file is: bootflash:///m9100-s6ek9-kickstart-mz.9.4.1a.bin      <<<<< 9132T
  kickstart compile time:  12/25/2023 12:00:00 [01/12/2024 09:04:07]
  system image file is:    bootflash:///m9100-s6ek9-mz.9.4.1a.bin
  system compile time:     12/25/2023 12:00:00 [01/12/2024 10:45:51]

Software
  BIOS:      version 1.07.0
  loader:    version N/A       <<<<<<<<< loader version displayed as N/A
  kickstart: version 9.4(2)
  system:    version 9.4(2)
  BIOS compile time:       12/18/2023
  kickstart image file is: bootflash:///m9124v-s8ek9-kickstart-mz.9.4.2.bin   <<<<<< 9124V
  kickstart compile time:  4/25/2024 12:00:00 [05/09/2024 20:44:44]
  system image file is:    bootflash:///m9124v-s8ek9-mz.9.4.2.bin
  system compile time:     4/25/2024 12:00:00 [05/09/2024 22:26:03]

Les commutateurs directeurs (indépendamment de sup-1, sup-4 ou de toute version NX-OS) n’affichent PAS la version du chargeur dans la sortie show version.
Software               <<<<<<<<< no loader version displayed
  BIOS:      version 3.8.0
  kickstart: version 8.4(2f)
  system:    version 8.4(2f)
  BIOS compile time:       04/23/2021
  kickstart image file is: bootflash:///m9700-sf3ek9-kickstart-mz.8.4.2f.bin   <<<<< sup-4
  kickstart compile time:  3/15/2023 12:00:00 [03/25/2023 00:47:55]
  system image file is:    bootflash:///m9700-sf3ek9-mz.8.4.2f.bin
  system compile time:     3/15/2023 12:00:00 [03/25/2023 02:37:14]

Software               <<<<<<<<< no loader version displayed
  BIOS:      version 4.10.0
  kickstart: version 9.4(2a)
  system:    version 9.4(2a)
  BIOS compile time:       03/14/2024
  kickstart image file is: bootflash:///m9700-sf4ek9-kickstart-mz.9.4.2a.bin    <<<<< sup-4
  kickstart compile time:  7/15/2024 12:00:00 [06/12/2024 14:13:36]
  system image file is:    bootflash:///m9700-sf4ek9-mz.9.4.2a.bin
  system compile time:     7/15/2024 12:00:00 [06/12/2024 16:03:45]

Cause

Il est conçu de telle sorte qu’il n’affiche pas la version du chargeur. Il semble que ce soit la raison pour laquelle Cisco a supprimé cette option dans les commutateurs directeurs.

Resolution

La version du chargeur affiche N/A conformément à la conception. Cela n’a aucun impact sur le commutateur.

Additional Information

Le guide de référence des commandes pour la sortie des versions 8.x et 9.x répertorie les détails de la version du chargeur.
Ici, la version « show version » provient du commutateur 9216i qui est en fin de vie/fin de service depuis 2013. Par conséquent, nous pouvons l’ignorer.


Affected Products

Connectrix MDS-Series

Products

Connectrix MDS 9132T
Article Properties
Article Number: 000228380
Article Type: Solution
Last Modified: 28 May 2025
Version:  2
Find answers to your questions from other Dell users
Support Services
Check if your device is covered by Support Services.