Cisco MDS:設定開機變數失敗,並顯示「實際映像類型與開機變數 (0x4045001E) 不相符」

Summary: 客戶執行從 NX-OS 6.2.23 至 9.4.2a 的中斷性升級。

This article applies to This article does not apply to This article is not tied to any specific product. Not all product versions are identified in this article.

Symptoms

用於設置引導變數的語法,如下所示:
switch(config)#
no boot system
switch(config)#
boot bootflash:<kickstart new_kickstart_image_name>
switch(config)#
boot bootflash:<system new_system_image_name>
switch(config)#
end
switch#
copy running-config startup-config
switch#
reload

客戶在 MDS 9148S 上執行下列命令:
MDS9148S(config)# boot kickstart bootflash:m9148-s6ek9-kickstart-mz.9.4.2a.bin

Performing image verification and compatibility check, please wait....
Failed to configure bootvar kickstart for sup-1: mismatch between actual image type and boot variable (0x4045001E)

Cause

Cisco MDS9148s 平台使用的映像不正確:
從 MDS9148s:
MDS9148s# show version
  kickstart image file is: bootflash:///m9100-s5ek9-kickstart-mz.6.2.23.bin
  kickstart compile time:  3/31/2018 23:00:00 [02/20/2018 18:47:57]
  system image file is:    bootflash:///m9100-s5ek9-mz.6.2.23.bin
  system compile time:     3/31/2018 23:00:00 [02/20/2018 19:58:46]

請注意,交換器的顯示版本為 :
-m9100-s5ek9
但是嘗試使用來自不同平台的映像設定開機變數將會失敗:
-m9148-s6ek9

Resolution

確保每個平台
使用正確的系統/kickstart 映像 可從各交換器類型下載平台映像:
https://www.dell.com/support/home/en-ie/product-support/product/connectrix/drivers

Affected Products

Connectrix MDS-9148S
Article Properties
Article Number: 000249589
Article Type: Solution
Last Modified: 12 Mar 2025
Version:  2
Find answers to your questions from other Dell users
Support Services
Check if your device is covered by Support Services.