VNX OE:如何解决故障切换期间的 PCI 组件不匹配错误
Summary: 本文介绍如何解决故障转移期间的 PCI 组件不匹配错误。
This article applies to
This article does not apply to
This article is not tied to any specific product.
Not all product versions are identified in this article.
Instructions
slot_2上的一个 I/O 模块出现故障,无法在数据移动器重新启动期间加载。为了在更换 I/O 模块之前恢复终端用户的访问,请将server_2故障切换到 slot_3。
但是,由于 I/O 模块出现故障,出现了 PCI 组件不匹配错误。[nasadmin@cs0 /]$ server_standby server_2 -activate moverserver_2 :Error 12032: server_2 : PCI components mismatch: blade hardware on standby server_3 does not match exactly the primary blade hardware.
要解决此问题,请关闭slot_2电源,然后再次进行故障切换。[nasadmin@cs0 /]$ /nas/sbin/t2reset pwroff -s 2[nasadmin@cs0 /]$ server_standby server_2 -activate moverserver_2 : server_2 : going offline server_3 : going active replace in progress ...done failover activity complete commit in progress (not interruptible)...done server_2 : renamed as server_2.faulted.server_3server_3 : renamed as server_2...
Additional Information
此解决方法仅适用于此特定情况。