VxRail: Nodo mancante dalla pagina fisica a causa di agenti CIM e Wbem disabilitati
Summary: I nodi VxRail possono scomparire dalla pagina quando l'interfaccia VMK1 viene rimossa. Ciò può essere causato da agenti CIM (Common Information Model) disabilitati e da un servizio WBEM inattivo che blocca i provider. ...
This article applies to
This article does not apply to
This article is not tied to any specific product.
Not all product versions are identified in this article.
Symptoms
Nodo mancante nella vista della pagina fisica (VMK1 scompare automaticamente).
Cause
CIM Gli agenti sono disabilitati sul nodo.
Resolution
- Verificare che
wbemè abilitato:esxcli system wbem get - Se
wbemè disabilitato, abilitarlo con il comando:esxcli system wbem set enable true - Verificare se tutte le
wbemVengono caricati i provider:localcli system wbem provider list[root@node1:] localcli system wbem provider list Name Enabled Loaded --------------------------------- sfcb_base true true vmw_base true true vmw_dcism true true vmw_hdr true true vmw_iodmProvider true true vmw_kmodule true true vmw_omc true true vmw_pci true true
- Se del caso
wbemi provider non vengono caricati, abilitareCIMagenti (sfcbd-watchdogewsman) utilizzando i comandi riportati di seguito.[root@vxrail-zone2-node-03:/opt/dell/srvadmin/iSM/bin] chkconfig sfcbd-watchdog sfcbd-watchdog off [root@vxrail-zone2-node-03:/opt/dell/srvadmin/iSM/bin] chkconfig sfcbd-watchdog on [root@vxrail-zone2-node-03:/opt/dell/srvadmin/iSM/bin] /etc/init.d/sfcbd-watchdog status sfcbd is not running [root@vxrail-zone2-node-03:/opt/dell/srvadmin/iSM/bin] /etc/init.d/sfcbd-watchdog start sfcbd-init: Getting Exclusive access, please wait... sfcbd-init: Exclusive access granted. sfcbd-init: Request to start sfcbd-watchdog, pid 2111224 sfcbd-config[2111234]: Configuration not changed, already enabled sfcbd-init: starting sfcbd sfcbd-init: Waiting for sfcb to start up. sfcbd-init: Program started normally. [root@vxrail-zone2-node-03:/opt/dell/srvadmin/iSM/bin] /etc/init.d/sfcbd-watchdog status sfcbd is running [root@vxrail-zone2-node-03:/opt/dell/srvadmin/iSM/bin] chkconfig wsman wsman off [root@vxrail-zone2-node-03:/opt/dell/srvadmin/iSM/bin] /etc/init.d/wsman status openwsmand is not running [root@vxrail-zone2-node-03:/opt/dell/srvadmin/iSM/bin] /etc/init.d/wsman start openwsmand: Getting Exclusive access, please wait... openwsmand: Exclusive access granted. openwsmand: Starting openwsmand [root@vxrail-zone2-node-03:/opt/dell/srvadmin/iSM/bin] /etc/init.d/wsman status openwsmand is running [root@vxrail-zone2-node-03:/opt/dell/srvadmin/iSM/bin] chkconfig wsman wsman off [root@vxrail-zone2-node-03:/opt/dell/srvadmin/iSM/bin] chkconfig wsman on
- Verificare ora che vmk1 sia stato creato sul nodo.
- Controllare la pagina fisica e verificare che il nodo sia integro.
Affected Products
VxRail, VxRail 460 and 470 Nodes, VxRail Appliance Series, VxRail G Series Nodes, VxRail D Series Nodes, VxRail E Series Nodes, VxRail P Series Nodes, VxRail S Series Nodes, VxRail Software, VxRail V Series Nodes, VxRail VD Series NodesArticle Properties
Article Number: 000049893
Article Type: Solution
Last Modified: 23 Dec 2025